The capability to detect changes in an underwater scene has many applications, including environmental monitoring, surveillance of strategic maritime waterways, and naval mine countermeasures. This paper examines the automated detection of changes in repeat-pass synthetic aperture sonar (SAS) imagery by exploiting the loss of phase coherence caused by differences in the scene. A renavigation method based on track registration is developed for performing the coregistration of images. The method first determines the corrections to be applied to the repeat-pass navigation data by optimizing a linear track model using the estimated across-track pixel displacements. A second optimization is then performed using the along-track pixel displacements to determine a velocity correction for each ping location of the repeat-pass image to compensate for residual motion errors. The corrected navigation solution is then used to rebeamform the repeat-pass image onto the same focal points as the reference image. The method is demonstrated on a pair of repeat-pass SAS images acquired using the AquaPix INSAS2 sonar, where it is shown that it is not necessary to have access to raw element data to coregister images accurately enough for coherent change detection requirements. This technique is then applied to the second data set obtained using the HISAS 1030 sonar for the purpose of comparing both coherent and noncoherent (amplitude-only) approaches to change detection in scenes with low and high clutters. False alarms caused by the acoustic shadows of objects in high-clutter areas are mitigated using the single-pass interferometric coherence as a reference mask. The results show the successful use of the repeat-pass coherence to detect changes between SAS images with temporal baselines of several days on scenes consisting of mud, gravel, and sand, and demonstrate that a coherent approach is capable of detecting large-scale differences (caused by the introduction or removal of targets) as well as subtle scene changes that are not detectable using noncoherent methods.
We proposed a novel solution for volumetric ultrasound imaging using single-side access 3-D synthetic aperture scanning of a clinical linear array. This solution is based on an advanced scanning geometry and a software-based ultrasound platform. The rotate-translate scanning scheme increases the elevation angular aperture by pivoting the array (−45° to 45°) around its array axis (axis along the row of its elements) and then scans the imaged object for each pivoted angle by translating the array perpendicularly to the rotation axis. A theoretical basis is presented so that the angular and translational scan sampling periods can be best adjusted for any linear transducer array. We experimentally implemented scanning with a 5-MHz array. In vitro characterization was performed with phantoms designed to test resolution and contrast. Spatial resolution assessed based on the full-width half-maximum of images from isolated microspheres was increased by a factor of 3 along the translational direction from a simple translation scan of the array. Moreover, the resolution was uniform over a cross-sectional area of 4.5 cm2. Angular sampling periods were optimized and tapered to decrease the scan duration while maintaining image contrast (contrast at the center of a 5-mm cyst on the order of −26 dB for 4° angular period and a scan duration of 10 s for a 9-cm3 volume). We demonstrated that superior 3-D ultrasound imaging can be obtained with a clinical array using our scanning strategy. This technique offers a promising and flexible alternative to development of costly matrix arrays toward the development of sensitive volumetric ultrasonography.
Change detection methods, consisting in detecting potential changes between two images, representing the same geographical area but acquired at different times, have been widely used in sonar imagery. Such methods are very useful to accurately monitor, potentially low, variations in complex environments. Coherent methods, relying on both amplitude and phase of the backscattered signal, are limited because of the signals correlation that plummets with both frequency and temporal baseline. In this paper, we propose an incoherent method, only using the amplitude images, to solve the change detection problem. This method relies on a robust mathematical expression for the class conditional probability density functions of the log-ratio image along with various Markov-based approaches to provide a ternary change map, thus allowing to better understand the changes that have occured on the seafloor.
Coastal environments, which are crucial for economic and strategic reasons, heavily rely on accurate bathymetry for safe navigation and resource monitoring. Recent advancements in through-water photogrammetry have shown promise in mapping shallow waters efficiently. However, robust uncertainty modeling methods for these techniques, especially in challenging coastal environments, are lacking. This study introduces a novel likelihood-based approach for through-water photogrammetry, focusing on uncertainties associated with camera pose—a key factor affecting depth mapping accuracy. Our methodology incorporates probabilistic modeling and stereo-photogrammetric triangulation to provide realistic estimates of uncertainty in Water Column Depth (WCD) and Water–Air Interface (WAI) height. Using simulated scenarios for both drone and airborne surveys, we demonstrate that viewing geometry and camera pose quality significantly influence resulting uncertainties, often overshadowing the impact of depth itself. Our results reveal the superior performance of the likelihood ratio statistic in scenarios involving high attitude noise, high flight altitude, and complex viewing geometries. Notably, drone-based applications show particular promise, achieving decimeter-level WCD precision and WAI height estimations comparable to high-quality GNSS measurements when using large samples. These findings highlight the potential of drone-based surveys in producing more accurate bathymetric charts for shallow coastal waters. This research contributes to the refinement of uncertainty quantification in bathymetric charting and sets a foundation for future advancements in through-water surveying methodologies.
1 January 2020 in Proceedings of Meetings on Acoustics
The notion spatial coherence is used by sonar systems such as Correlation Velocity Logs (CVL) and Synthetic Aperture Sonars (SAS). It exploits correlation between acoustic signals sensed in space and time to estimate for example platform displacement. The Van Cittert Zernike (VCZ) theorem, is a classical statistical optics theorem that predicts the spatial coherence of a pressure field backscattered by a random medium. However it appears that intrinsic characteristics of Low Frequency Synthetic Aperture Sonar (LFSAS) can breach VCZ asumptions. In this paper, the notion of spatial coherence applied to a Low Frequency SAS system (LFSAS) is investigated. In a first part, the notion of spatial coherence and the VCZ therorem is presented. Then the High Resolution LFSAS (HRLFSAS) developed by NATO CMRE and used in this work is introduced. In the same time, a simulation tool is presented. In this paper, typical coherence functions obtained on simulation are presented. That allows to point out the link between the shape of the coherence function and the length of the transmit antenna. These functions are compared to the coherence observed on LFSAS data. Differences are investigated in terms of signal to noise ratio.