Zhicheng Yang

Mr. Zhicheng Yang

University of Twente
+1
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 July 2020 in Sensors
Verified
Journal Article
Open access
PDF file
ZYZhicheng Yang
Zhicheng Yang
BBBert-Jan van Beijnum
Bert-Jan van Beijnum
LBLi Bin
Li Bin
SYShenggang Yan
Shenggang Yan
PVPeter Veltink
Peter Veltink
Relative orientation estimation between the hand and its fingers is important in many applications, such as virtual reality (VR), augmented reality (AR) and rehabilitation. It is still quite a big challenge to do the estimation by only exploiting inertial measurement units (IMUs) because of the integration drift that occurs in most approaches. When the hand is functionally used, there are many instances in which hand and finger tips move together, experiencing almost the same angular velocities, and in some of these cases, almost the same accelerations are measured in different 3D coordinate systems. Therefore, we hypothesize that relative orientations between the hand and the finger tips can be adequately estimated using 3D IMUs during such designated events (DEs) and in between these events. We fused this extra information from the DEs and IMU data with an extended Kalman filter (EKF). Our results show that errors in relative orientation can be smaller than five degrees if DEs are constantly present and the linear and angular movements of the whole hand are adequately rich. When the DEs are partially available in a functional water-drinking task, the orientation error is smaller than 10 degrees.

15 April 2019 in IEEE Magnetics Letters
Verified
Journal Article
Closed access
ZYZhicheng Yang
Zhicheng Yang
SYShenggang Yan
Shenggang Yan
LCLianping Chen
Lianping Chen
LBLi Bin
Li Bin
The performance of Scalar Triangulating and Ranging (STAR) method is limited by the asphericity error. Some iterative strategies are proposed to reduce the error and the performance has been improved. However, iterative methods are still facing problems such as multiple iterations, singularity and limited accuracy. In light of this situation, an eigenvalue method which is primarily based on the property of gradient tensor eigenvalues is proposed, a new rotationally invariant scalar related to eigenvalues is used to replace the old one, which can eliminate the asphericity error radically. Furthermore, a new strategy for estimating the length of bearing vector is proposed, which is simpler and can be used to avoid singular problems. The formula for estimating the bearing vector is more concise and direct with these two major improvements. The results show the performance of eigenvalue method performs better than STAR method and iterative method.

3 June 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
ZYZhicheng Yang
Zhicheng Yang
SYShenggang Yan
Shenggang Yan
BBBert-Jan van Beijnum
Bert-Jan van Beijnum
LBLi Bin
Li Bin
PVPeter Veltink
Peter Veltink
Hand-finger motion tracking based on inertial and magnetic measurement units (IMMUs) has become a well-accepted method in many applications such as rehabilitation and virtual reality. However, existing systems require an IMMU on each segment of the whole hand and known length of each segment, which is hard to achieve for users. Therefore, we proposed a small sensor configuration with three IMMUs and a magnet to estimate poses of interested fingertips relative to the hand. The relative orientations were estimated by integrating relative angular velocity and fused with relative orientation estimation during time intervals when the whole hand moved or rotated as one object. The relative positions were estimated by using a magnetic dipole model of the magnet and prior estimated relative orientations. The performance has been demonstrated in multiple experiments. For whole hand rotation and functional grasping or writing experiments, the estimated errors of index fingertip position and orientation relative to the hand were 8.0~9.8 mm and 5.7° ~11.2°. For index finger flexion and pinching, the estimated errors of index fingertip position and orientation relative to the hand were 16.2~25.2 mm and 20.6° ~ 21.7°.

14 April 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ZYZhicheng Yang
Zhicheng Yang
SYShenggang Yan
Shenggang Yan
BBBert-Jan van Beijnum
Bert-Jan van Beijnum
LBLi Bin
Li Bin
PVPeter Veltink
Peter Veltink
Optical tracking systems (OTS) can provide high position accuracy over a large workspace. However, the orientation from the OTS is related to the distance between markers, which contains large errors when the distance is small or line-of-sight problems occur. The orientation estimation with a gyroscope is complementary to the OTS-based orientation. In this article, an error-state Kalman filter (ESKF) is proposed to fuse them. Two experiments were performed to verify the performance: first, a unit including markers and a gyroscope was placed statically and rotated dynamically in 3-D space. Secondly, two units were used to estimate the relative orientation between the hand and fingers. The static and dynamic orientation errors reduced from 0.39° ± 0.16° and 2.75° ± 1.56° to 0.23° ± 0.02° and 1.50° ± 0.62°, respectively, when the distance between markers was 13 mm. The second experimental results show that the fused method improved the OTS performance by smoothing the estimate, filling the relative orientation during the line of sight period, and correcting the estimation when there were identification problems of markers.

23 October 2018 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
ZYZhicheng Yang
Zhicheng Yang
LBLi Bin
Li Bin
CLChen Lianping
Chen Lianping
The performance of a three-axis magnetometer (TAM) is limited by various types of error; hence, the system must be calibrated prior to use. The convergence of calibration algorithms is quite sensitive to input data, and divergence yields incorrect parameter-estimation results when the maneuvers of TAM are constrained. Therefore, a calibration method, based primarily on improved truncated singular value decomposition, was proposed. The singular values were divided into groups; the small values were modified, whereas the large values were retained (without modification). Information with improved accuracy was obtained from these large values, while the less accurate information contained in the smaller values was modified, thereby avoiding divergent solutions. The experimental results revealed that the performance of TAM was significantly improved by the use of the proposed calibration method.

6 May 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ZYZhicheng Yang
Zhicheng Yang
SYShenggang Yan
Shenggang Yan
BBBert-Jan van Beijnum
Bert-Jan van Beijnum
LBLi Bin
Li Bin
PVPeter Veltink
Peter Veltink
Inertial-sensor-based hand motion tracking has become a well-accepted method in many clinical applications including rehabilitation of the upper extremity etc. However, major drawbacks are that a sensor on each segment and kinematic chain rule are required. Thus, errors accumulate through the kinematic chain rule. Also, the length of each segment needs to be measured for each user. We propose a novel method in which a permanent magnet on the dorsal side of the hand combined with an inertial sensor and a magnetometer (IMMU) on the fingertip are used to estimate the position of the thumb and index fingertip relative to the position of the dorsal side of the hand. The biggest advantages of the proposed method are that no prior information and kinematic chain rule are needed. Besides, the required number of sensors is low. A Levenberg–Marquardt (L-M) approach is presented to estimate the relative positions with the known orientations. The performance is demonstrated in multiple experiments in which various movement tasks were performed. The most complex task in which participants performed reaching and grasping movements based on action research arm test (ARAT) resulted in median distance error between thumb and index finger of 9.6%.