Magnetic anomaly detection (MAD) technology has been widely used in geological exploration, unexploded ordnance exploration, wreck salvage, and other fields because of its attractive advantages such as all-weather implementation, high concealment, and signal propagation in water and soil. The most classic method in MAD is orthonormal basis functions (OBFs) detection which can effectively detect the magnetic target in a comparatively low signal-to-noise ratio (SNR) environment. In this article, attracted by the excellent properties of magnetic gradient tensor (MGT) invariant, the ${{\mathrm{I}}_{1}}$ -OBF and ${{\mathrm{I}}_{2}}$ -OBF methods are developed. Considering strong dependence of the ${{\mathrm{I}}_{2}}$ -OBF method on the angle between magnetic moment vector and displacement vector, and moderate detection performance of the ${{\mathrm{I}}_{1}}$ -OBF method, an effective invariant-OBF method through adaptively integrating search energy of the ${{\mathrm{I}}_{1}}$ -OBF and ${{\mathrm{I}}_{2}}$ -OBF methods is proposed. Simulations and field experiments witnessed a great improvement in the SNR of the proposed method from the perspective of signal energy. It is proved that the proposed method can stably produce promising results even under the shaking-platform condition or the specific geometric relationship between the magnetic moment vector and the displacement vector.
Magnetic detection technology has wide applications in the fields of geological exploration, biomedical treatment, wreck removal and localization of unexploded ordinance. A large number of methods have been developed to locate targets with static magnetic fields, however, the relation between the problem of localization of moving objectives with alternating magnetic fields and the localization with a static magnetic field is rarely studied. A novel method of target localization based on coherent demodulation was proposed in this paper. The problem of localization of moving objects with an alternating magnetic field was transformed into the localization with a static magnetic field. The Levenberg-Marquardt (L-M) algorithm was applied to calculate the position of the target with magnetic field data measured by a single three-component magnetic sensor. Theoretical simulation and experimental results demonstrate the effectiveness of the proposed method.
Relative orientation estimation between the hand and its fingers is important in many applications, such as virtual reality (VR), augmented reality (AR) and rehabilitation. It is still quite a big challenge to do the estimation by only exploiting inertial measurement units (IMUs) because of the integration drift that occurs in most approaches. When the hand is functionally used, there are many instances in which hand and finger tips move together, experiencing almost the same angular velocities, and in some of these cases, almost the same accelerations are measured in different 3D coordinate systems. Therefore, we hypothesize that relative orientations between the hand and the finger tips can be adequately estimated using 3D IMUs during such designated events (DEs) and in between these events. We fused this extra information from the DEs and IMU data with an extended Kalman filter (EKF). Our results show that errors in relative orientation can be smaller than five degrees if DEs are constantly present and the linear and angular movements of the whole hand are adequately rich. When the DEs are partially available in a functional water-drinking task, the orientation error is smaller than 10 degrees.
The performance of Scalar Triangulating and Ranging (STAR) method is limited by the asphericity error. Some iterative strategies are proposed to reduce the error and the performance has been improved. However, iterative methods are still facing problems such as multiple iterations, singularity and limited accuracy. In light of this situation, an eigenvalue method which is primarily based on the property of gradient tensor eigenvalues is proposed, a new rotationally invariant scalar related to eigenvalues is used to replace the old one, which can eliminate the asphericity error radically. Furthermore, a new strategy for estimating the length of bearing vector is proposed, which is simpler and can be used to avoid singular problems. The formula for estimating the bearing vector is more concise and direct with these two major improvements. The results show the performance of eigenvalue method performs better than STAR method and iterative method.
Magnetic detection techniques have been widely used in many fields, such as virtual reality, surgical robotics systems, and so on. A large number of methods have been developed to obtain the position of a ferromagnetic target. However, the angular rotation of the target relative to the sensor is rarely studied. In this paper, a new method for localization of moving object to determine both the position and rotation angle with three magnetic sensors is proposed. Trajectory localization estimation of three magnetic sensors, which are collinear and noncollinear, were obtained by the simulations, and experimental results demonstrated that the position and rotation angle of ferromagnetic target having roll, pitch or yaw in its movement could be calculated accurately and effectively with three noncollinear vector sensors.
Hand-finger motion tracking based on inertial and magnetic measurement units (IMMUs) has become a well-accepted method in many applications such as rehabilitation and virtual reality. However, existing systems require an IMMU on each segment of the whole hand and known length of each segment, which is hard to achieve for users. Therefore, we proposed a small sensor configuration with three IMMUs and a magnet to estimate poses of interested fingertips relative to the hand. The relative orientations were estimated by integrating relative angular velocity and fused with relative orientation estimation during time intervals when the whole hand moved or rotated as one object. The relative positions were estimated by using a magnetic dipole model of the magnet and prior estimated relative orientations. The performance has been demonstrated in multiple experiments. For whole hand rotation and functional grasping or writing experiments, the estimated errors of index fingertip position and orientation relative to the hand were 8.0~9.8 mm and 5.7° ~11.2°. For index finger flexion and pinching, the estimated errors of index fingertip position and orientation relative to the hand were 16.2~25.2 mm and 20.6° ~ 21.7°.