Moosa Abuzayeda

Dr. Moosa Abuzayeda

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 March 2021 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Tarek M. ElshazlyTarek M. Elshazly
Tarek M. Elshazly
LKLudger Keilig
Ludger Keilig
YAYasmine Alkabani
Yasmine Alkabani
AGAhmed Ghoneima
Ahmed Ghoneima
MAMoosa Abuzayeda
Moosa Abuzayeda
CBChristoph P Bourauel
Christoph P Bourauel
As an innovative approach to overcome the rate-limiting staging of conventional aligners, using shape memory polymers (SMPs) as aligners’ materials was investigated in this in vitro study. The ability of SMPs to shape recover and consequently move tooth, upon appropriate stimuli, was evaluated on a typodont model before clinical application. The study design was to achieve 1.9 mm correction movement of an upper central incisor by one aligner after multiple steps/activation. A custom-made aligned typodont model with a movable upper central incisor was scanned. Using an orthodontic software and a 3D printer, resin-models were generated. Seven aligners of ClearX sheets (SMPs) were fabricated by thermoforming on the resin aligned model. Each aligner was tested for repositioning of the central incisor in the typodont model. The model was scanned after each step and the corrective movement was measured through the superimposition of scans. Results showed that the total correction efficiency of the SMPs’ aligner was ≈93% (1.76 mm). The corrective movement was 0.94 ± 0.04 mm after the reforming step, 0.66 ± 0.07 mm after the first activation step, and 0.15 ± 0.10 mm after the second activation step. It was concluded that aligners made of SMPs could have a promising future-use in orthodontic aesthetic treatment.

17 January 2023 in Materials
Verified
Journal Article
Open access
PDF file
SQSyed Saad Bin Qasim
Syed Saad Bin Qasim
AAAdel Al-Asfour
Adel Al-Asfour
MAMoosa Abuzayeda
Moosa Abuzayeda
AMAhmed Meslam Mohamed
Ahmed Meslam Mohamed
BTBranko Trajkovski
Branko Trajkovski
GZGregor Georg Zafiropoulos
Gregor Georg Zafiropoulos
Non-resorbable PTFE membranes are frequently used in dental-guided bone regeneration (GBR). However, there is a lack of detailed comparative studies that define variations among commonly used PTFE membranes in daily dental clinical practice. The aim of this study was to examine differences in physicochemical and mechanical properties of several recent commercial PTFE membranes for dental GBR (CytoplastTM TXT-200, permamem®, NeoGen®, Surgitime, OsseoGuard®-TXT, OsseoGuard®-NTXT). Such differences have been rarely recorded so far, which might be a reason for the varied clinical results. For that reason, we analyzed their surface architecture, chemical composition, tensile strength, Young’s modulus, wettability, roughness, density, thickness and porosity. SEM revealed different microarchitectures among the non-textured membranes; the textured ones had hexagonal indentations and XPS indicated an identical spectral portfolio in all membranes. NeoGen® was determined to be the strongest and OsseoGuard®-TXT was the most elastic. Wettability and roughness were highest for Surgitime but lowest for OsseoGuard®-NTXT. Furthermore, permamem® was the thinnest and NeoGen® was identified as the thickest investigated GBR membrane. The defect volumes and defect volume ratio (%) varied significantly, indicating that permamem® had the least imperfect structure, followed by NeoGen® and then Cytoplast TM TXT-200. These differences may potentially affect the clinical outcomes of dental GBR procedures.

15 July 2024 in Prosthesis
Verified
Journal Article
Open access
PDF file
Kelvin Ian AfrashtehfarKelvin Ian Afrashtehfar
Kelvin Ian Afrashtehfar
MAMoosa Abuzayeda
Moosa Abuzayeda
CMColin Murray
Colin Murray
In recent years, artificial intelligence (AI) has emerged as a transformative force in reconstructive implant dentistry

12 September 2021 in Membranes
Verified
Journal Article
Open access
PDF file
GZGregor Georg Zafiropoulos
Gregor Georg Zafiropoulos
AAAdel Al-Asfour
Adel Al-Asfour
MAMoosa Abuzayeda
Moosa Abuzayeda
Zeljka Peric KacarevicZeljka Peric Kacarevic
Zeljka Peric Kacarevic
CMColin Murray
Colin Murray
BTBranko Trajkovski
Branko Trajkovski
Peri-implant keratinized mucosa (PI-KM) may support implant survival. Acellular collagen matrices (aCMs) have been widely used to facilitate soft tissue regeneration. The aim of this study was to investigate clinical outcomes obtained with the use of an aCM (mucoderm®) to enhance PI-KM. In this retrospective non-randomized case series, 27 restored implants in 14 patients (eight males and six females, mean age = 56 years) with a PI-KM width ≤ 1 mm were followed for 6 months. It was demonstrated that aCM grafts augmented PI-KM effectively (mean increase of 5.4 mm; >533%) without a significant change in bleeding on probing (BOP) from baseline. The mean aCM shrinkage was 3.9 mm (42%). Gender, area, arch, and BOP did not influence PI-KM augmentation or aCM shrinkage significantly. The present results demonstrated that the examined aCM was effective and predictable for attaining a band of keratinized tissue, while avoiding graft donor site harversting.

27 April 2023 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
AAAhmad Alanezi
Ahmad Alanezi
MAMay Aljanahi
May Aljanahi
Keyvan MoharamzadehKeyvan Moharamzadeh
Keyvan Moharamzadeh
AGAhmed Ghoneima
Ahmed Ghoneima
ATAbdel Rahman Tawfik
Abdel Rahman Tawfik
MAMoosa Abuzayeda
Moosa Abuzayeda
Background: Recording accurate impressions from maxillary defects is a critical and challenging stage in the prosthetic rehabilitation of patients following maxillectomy surgery. The aim of this study was to develop and optimize conventional and 3D-printed laboratory models of maxillary defects and to compare conventional and digital impression techniques using these models. Methods: Six different types of maxillary defect models were fabricated. A central palatal defect model was used to compare conventional silicon impressions with digital intra-oral scanning in terms of dimensional accuracy and total time taken to record the defect and produce a laboratory analogue. Results: Digital workflow produced different results than the conventional technique in terms of defect size measurements which were statistically significant (p < 0.05). The time taken to record the arch and the defect using an intra-oral scanner was significantly less compared with the traditional impression method. However, there was no statistically significant difference between the two techniques in terms of the total time taken to fabricate a maxillary central defect model (p > 0.05). Conclusions: The laboratory models of different maxillary defects developed in this study have the potential to be used to compare conventional and digital workflow in prosthetic treatment procedures.

9 May 2022 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
YDYahya Deeban
Yahya Deeban
Keyvan MoharamzadehKeyvan Moharamzadeh
Keyvan Moharamzadeh
MAMoosa Abuzayeda
Moosa Abuzayeda
NMNicolas Martin
Nicolas Martin
Background: This study aimed to develop a tooth wear classification system that combined the extent, severity, and aesthetic impact of tooth wear and correlated them with the most appropriate clinical management strategy. Methods: Three hundred photographs were used to develop a classification tool that contained four levels of severity and aesthetic impact (0, 1, 2, and 3) in three age groups of patients. Ten examiners assessed and classified the cases using validated forms. Additionally, they selected the recommended treatment modality for each level. The analysis was conducted using a coefficient correlation test. Results: The coefficient correlation for the severity was 0.81, 0.82 in the upper anterior and posterior segments, and 0.85 and 0.77 for the lower anterior and posterior segments, respectively. The aesthetic impact correlation coefficient was 0.84. Examiners had agreed that minor cases required monitoring or simple restorative interventions. The moderate-level cases had variety in the recommended management options depending on the aim of treatment. The severe level cases often required rehabilitation at an increased occlusal vertical dimension. Conclusion: Within the limitations of this preliminary study, a good agreement between the examiners was found using the provided tools. More strict criteria in the classification part of the tool can further improve the examiners’ agreement.