The penetration of electrical vehicles (EVs) is exponentially rising to decarbonize the transport sector resulting in the research problem regarding the future of their retired batteries. Landfill disposal poses an environmental hazard, therefore, recycling or reusing them as second-life batteries (SLBs) are the inevitable options. Reusing the EV batteries with significant remaining useful life in stationary storage applications maximizes the economic benefits while extending the useful lifetime before recycling. Following a critical review of the research in SLBs, the key areas were identified as accurate State of Health (SOH) estimation, optimization of health indicators, battery life cycle assessment including repurposing, End-Of-Life (EOL) extension techniques and significance of first-life degradation data on ageing in second-life applications. The inconsistencies found in the reviewed literature showed that the absence of degradation data from first as well as second life, has a serious impact on accurate remaining useful life (RUL) prediction and SOH estimation. This review, for the first time, critically surveyed the recent studies in the field of identification, selection and control of application-based health indicators in relation to the accurate SOH estimation, offering future research directions in this emerging research area. In addition to the technical challenges, this paper also analyzed the economic perspective of SLBs, highlighting the impact of accuracy in second-life SOH estimation and RUL extension on their projected revenue in stationary storage applications. Lack of standard business model based on future market trends of energy and battery pricing and governing policies for SLBs are identified as urgent research gaps.
A fundamental strategy for utilizing green energy from renewable sources to tackle global warming is the microgrid (MG). Due to the predominance of AC microgrids in the existing power system and the substantial increase in DC power generation and DC load demand, the development of AC/DC hybrid microgrids (HMG) is inevitable. Despite increased theoretical efficiency and minimized AC/DC/AC conversion losses, uncertain loading, grid outages, and intermittent complexion of renewables have increased the complexity, which poses a significant threat toward system stability in an HMG. As a result, the amount of research on the stability, management, and control of HMG is growing exponentially, which makes it imperative to recognize existing problems and emerging trends. In this survey, several strategies from the most recent literature developed to address the challenges of HMG are reviewed. Power flow analysis, power sharing (energy management), local and global control of DGs, and a brief examination of the complexity of HMG’s protection plans make up the four elements of the review technique in this article. During critical analysis, the test system employed for validation is also taken into consideration. A comprehensive review of the literature demonstrates that MILP is a frequently employed technique for the supervisory control of HMG, whereas tweaking bidirectional converter control is the most common approach in the literature to achieve efficient power sharing. Finally, this review identified the limitations, undiscovered challenges, and major hurdles that need to be addressed in order to develop a sustainable control and management scheme for stable multimode HMG operation.
In recent years significant changes in climate have pivoted the distribution system towards renewable energy, particularly through distributed generators (DGs). Although DGs offer many benefits to the distribution system, their integration affects the stability of the system, which could lead to blackout when the grid is disconnected. The system frequency will drop drastically if DG generation capacity is less than the total load demand in the network. In order to sustain the system stability, under-frequency load shedding (UFLS) is inevitable. The common approach of load shedding sheds random loads until the system’s frequency is recovered. Random and sequential selection results in excessive load shedding, which in turn causes frequency overshoot. In this regard, this paper proposes an efficient load shedding technique for islanded distribution systems. This technique utilizes a voltage stability index to rank the unstable loads for load shedding. In the proposed method, the power imbalance is computed using the swing equation incorporating frequency value. Mixed integer linear programming (MILP) optimization produces optimal load shedding strategy based on the priority of the loads (i.e., non-critical, semi-critical, and critical) and the load ranking from the voltage stability index of loads. The effectiveness of the proposed scheme is tested on two test systems, i.e., a 28-bus system that is a part of the Malaysian distribution network and the IEEE 69-bus system, using PSCAD/EMTDC. Results obtained prove the effectiveness of the proposed technique in quickly stabilizing the system’s frequency without frequency overshoot by disconnecting unstable non-critical loads on priority. Furthermore, results show that the proposed technique is superior to other adaptive techniques because it increases the sustainability by reducing the load shed amount and avoiding overshoot in system frequency.
Unleashing the potential of distributed renewable energy sources (RESs), intelligent and autonomous microgrids are becoming pivotal in attaining net‐zero carbon emission goals. Hybrid AC/DC microgrids rise as cutting‐edge microgrid topologies, capitalising on the best of both AC and DC systems. However, the integration of intermittent renewables and uncertainties in loading poses stability challenges. Advanced bidirectional converter controls provide efficient power exchange, but in extreme contingencies, a resilient supervisory control framework (load management/load curtailment approach) is inevitable to withstand/avoid unplanned renewable disruptions/blackouts. Moreover, the operational paradigm shift towards achieving net‐zero emissions, isolated operation of RESs, and conventional load shedding methods are anticipated to encounter substantial challenges, necessitating the development of alternative strategies. In order to improve the stability of hybrid microgrid systems in islanding scenarios, this research presents an energy balancing and load curtailment strategy. The proposed method aims at optimising resource utilisation, prioritising essential loads, and executing an optimal load curtailment strategy (if required), thereby augmenting the stability of systems. Unlike a meta‐heuristic or exhaustive search, which depends on 2 n − 1 possible combinations and become unworkable as load numbers increase, the suggested methodology is based on a mathematically modelled load restriction method. By including load criticality, this strategy effectively prevents blackouts even with an increasing number of loads, providing a significantly more useful and practical solution. Additionally, the proposed charging algorithm ensures that the energy storage system imports energy from the grid during off‐peak hours and maximises power generation from the DC subgrid. The efficacy of the proposed strategy is validated using a modified IEEE‐33 bus system as a test case for a hybrid AC/DC microgrid. Simulation results demonstrate the effectiveness of the MILP‐based load curtailment approach in maintaining system stability and preventing blackouts during unforeseen events.