The penetration of electrical vehicles (EVs) is exponentially rising to decarbonize the transport sector resulting in the research problem regarding the future of their retired batteries. Landfill disposal poses an environmental hazard, therefore, recycling or reusing them as second-life batteries (SLBs) are the inevitable options. Reusing the EV batteries with significant remaining useful life in stationary storage applications maximizes the economic benefits while extending the useful lifetime before recycling. Following a critical review of the research in SLBs, the key areas were identified as accurate State of Health (SOH) estimation, optimization of health indicators, battery life cycle assessment including repurposing, End-Of-Life (EOL) extension techniques and significance of first-life degradation data on ageing in second-life applications. The inconsistencies found in the reviewed literature showed that the absence of degradation data from first as well as second life, has a serious impact on accurate remaining useful life (RUL) prediction and SOH estimation. This review, for the first time, critically surveyed the recent studies in the field of identification, selection and control of application-based health indicators in relation to the accurate SOH estimation, offering future research directions in this emerging research area. In addition to the technical challenges, this paper also analyzed the economic perspective of SLBs, highlighting the impact of accuracy in second-life SOH estimation and RUL extension on their projected revenue in stationary storage applications. Lack of standard business model based on future market trends of energy and battery pricing and governing policies for SLBs are identified as urgent research gaps.
A fundamental strategy for utilizing green energy from renewable sources to tackle global warming is the microgrid (MG). Due to the predominance of AC microgrids in the existing power system and the substantial increase in DC power generation and DC load demand, the development of AC/DC hybrid microgrids (HMG) is inevitable. Despite increased theoretical efficiency and minimized AC/DC/AC conversion losses, uncertain loading, grid outages, and intermittent complexion of renewables have increased the complexity, which poses a significant threat toward system stability in an HMG. As a result, the amount of research on the stability, management, and control of HMG is growing exponentially, which makes it imperative to recognize existing problems and emerging trends. In this survey, several strategies from the most recent literature developed to address the challenges of HMG are reviewed. Power flow analysis, power sharing (energy management), local and global control of DGs, and a brief examination of the complexity of HMG’s protection plans make up the four elements of the review technique in this article. During critical analysis, the test system employed for validation is also taken into consideration. A comprehensive review of the literature demonstrates that MILP is a frequently employed technique for the supervisory control of HMG, whereas tweaking bidirectional converter control is the most common approach in the literature to achieve efficient power sharing. Finally, this review identified the limitations, undiscovered challenges, and major hurdles that need to be addressed in order to develop a sustainable control and management scheme for stable multimode HMG operation.
The outbreak of SARS-COV-2 disease 2019 (COVID-19) abruptly changed the patterns in electricity consumption, challenging the system operations of forecasting and balancing supply and demand. This is mainly due to the mitigation measures that include lockdown and work from home (WFH), which decreased the aggregated demand and remarkably altered its profile. Here, we characterise these changes with various quantitative markers and compare it with pre-lockdown business-as-usual data using Great Britain (GB) as a case study. The ripple effects on the generation portfolio, system frequency, forecasting accuracy and imbalance pricing are also analysed. An energy data extraction and pre-processing pipeline that can be used in a variety of similar studies is also presented. Analysis of the GB demand data during the March 2020 lockdown indicates that a shift to WFH will result in a net benefit for flexible stakeholders, such as consumers on variable tariffs. Furthermore, the analysis illustrates a need for faster and more frequent balancing actions, as a result of the increased share of renewable energy in the generation mix. This new equilibrium of energy demand and supply will require a redesign of the existing balancing mechanisms as well as the longer-term power system planning strategies.
Batteries offer a combination of balancing and regulation services within a smart grid to improve its resilience and flexibility. Maintaining an acceptable state of health and the highest rate of return requires dynamic modelling of the asset and rigorous optimisation. The authors compare the technical cost and economic benefit of battery employment in dynamic frequency and balancing mechanism actions in a smart grid. They use the services procured by National Grid in the UK as a case study but the methodology is globally applicable, including developing grid infrastructures. Their methodology yields the most optimum scenario of service participation, accounting for the dynamic degradation and considering variable pricing of electricity throughout the day. Additionally, it advises the most optimal despatch schedule and price declarations for the battery over the course a day and a year, employing particle swarm optimisation algorithm and historic data. Their results demonstrate that ordinarily frequency response is preferred due to its lower technical toll and payments for availability rather than despatch. However, the proposed despatch schedule including both services provides the highest profit. They anticipate this methodology to become the basis for more sophisticated battery models that integrate the service despatch optimisation, dynamic lifetime degradation and economic analysis.