The article dealt with the load-bearing capacity and durability of power line lattice towers designed from weathering steel. Attention was paid in particular to the bolted lap joints. The article evaluates the static and corrosion performance of bolted lap joints in long-term operating towers, and also presents and evaluates design measures that can be applied in the design of new lattice towers, or in the reconstruction of already operating structures. Power line lattice towers are the most extensive realization of weathering steel in the Czech Republic. On the basis of the inspections carried out to evaluate the working life of the transmission towers in operation, it can be stated that a sufficiently protective layer of corrosion products generally developed on the bearing elements of the transmission towers. However, the development of crevice corrosion at the bolted joints of the leg members is a significant problem. In this paper, the corrosion damage of bolted joints was evaluated considering two basic aspects: (1) the influence of crevice corrosion on the bearing capacity of the bolted joint was evaluated, using experimental testing and based on analytical and numerical calculations; (2) appropriate design measures applicable to the rehabilitation of developed crevice corrosion of in-service structures, or the elimination of crevice corrosion in newly designed lattice towers, was evaluated. Calculation analyses and destructive tests of bolted joints show that the development of corrosion products in the crevice does not have a significant effect on the bearing capacity of the joint, provided that there is no significant corrosion weakening of the structural elements, and bolts of class 8.8 or 10.9 are used. The results of the long-term experimental programme, and the experience from the rehabilitations carried out, show that, thanks to appropriate structural measures, specified in detail in the paper, the long-term reliable behaviour of the lattice towers structures is ensured.
This article examines the effects of very high temperatures (300–1000 °C) on the physical, mechanical, and thermal behaviour of medium-grained lightweight mortars incorporating expanded perlite (EP) and three cement types: Ordinary Portland (OPC), Calcium Sulphoaluminate (CSAC), and Calcium Aluminate (CAC). Mortars with 0–100% EP replacement were tested for compressive strength, density, absorbability, thermal conductivity, and microstructure. Increasing EP content reduced density and strength but enhanced thermal insulation and dimensional stability. Above 650 °C, OPC and CSAC underwent dehydration, ettringite loss, and microcracking, while CAC developed stable phases that preserved cohesion and colour. Strong correlations were found between thermal conductivity and compressive strength, allowing predictive modelling across temperatures. Polynomial correlations best described the strength–temperature relationship for OPC and CAC, while logarithmic models were optimal for CSAC. Overall, CAC-EP mortars demonstrated superior thermal stability, mechanical retention, and durability, highlighting their suitability for refractory and energy-efficient construction applications.
One of the options for rehabilitating existing masonry buildings is a post-tensioning of masonry. The deformation properties of the masonry in the direction parallel to bed joints are essential for the design of a suitable value of the applied force. However, these values are usually not available or are defined only roughly. The aim of this study was to determine, as accurately as possible, the deformation characteristics of the masonry in the direction parallel to the bed joints. Experimental measuring of masonry samples was carried out in laboratory facilities designed specifically for testing the triaxial state of stress of the masonry. The obtained deformations were used to determine the modulus of elasticity of the masonry in the direction of bed joints. Within these experimental tests, laboratory measuring of mechanical masonry properties was carried out, and deformation characteristics were defined on the basis of calculations. The strengths of masonry units and mortar were tested in the laboratory and, according to the tests results, the modulus of elasticity in the direction perpendicular to bed joints was determined. The modulus of elasticity in the direction parallel to bed joints was verified through a simple numerical model. The calculated deformations were compared with the measured values. On the basis of the determination of the deformation characteristics of masonry in the direction of bed joints, the ratios of the modulus of elasticity in the direction perpendicular and parallel to bed joints were concluded.
1 January 2010 in Transactions of the VŠB – Technical University of Ostrava, Civil Engineering Series