This paper presents a novel high voltage conversion ratio (HVCR) bidirectional CLTC resonant DC-DC converter. Based on LLC, SRC and CLLC, the novel CLTC structure is proposed. With the use of auxiliary transformer and extra resonant capacitor, CLTC resonant DC-DC converter can achieve zero voltage switching (ZVS) in all load range. Also, CLTC has a good gain characteristic with high power load. In this study, a review of the statuses for the isolated HVCR bidirectional converters is made. The operating principle of bidirectional power flow in two directions is analyzed in details. In addition, by changing AC output resistance, a modified fundamental harmonic analysis (FHA) method makes the calculated gain curve more accurate than traditional FHA. Also, voltage and current stresses of power switches and resonant capacitors are given. A parameter optimization method is proposed to minimize the impedance angle of CLTC, which corresponds to less reactive power and turn-off current. The optimal parameters show advantages in voltage and current stresses. Moreover, power losses are analyzed in this study, showing advantage of CLTC in efficiency. At last, the experimental results based on a 5 kW prototype converter are presented to validate the theoretical analyses.
5 October 2021 in IEEE Transactions on Industrial Electronics
As an effective application form for large-scale and efficient use of distributed power, microgrid not only realizes the flexible control of distributed power but also provides reliable power supply for the load. However, the power quality on the load side will be severely deteriorated when the microgrid is disturbed. To cope with this issue, an improve linear active disturbance rejection control (LADRC) technique is proposed in this article. In this technology, the idea of series correction is introduced into the disturbance observation channel of linear extended state observer. This strategy can achieve more accurate tracking of disturbance items through the correction link, and handle the unknown modeling error and external disturbances of the system as an overall disturbance through a single structure. Then, according to the linear feedback law to achieve good control of the output-side converter. Moreover, the traceability, convergence, and stability of ILADRC are analyzed. More importantly, guidance on parameters configuration is given on the basis of performance analysis. Finally, the validity of the proposed improved LADRC technique is verified on a 40-kW experiment platform.
29 June 2021 in IEEE Transactions on Industrial Electronics
Hybrid energy storage microgrid represents the future direction of distributed energy development. However, under the influence of interference, the dynamic performance of the output side interface will be severely deteriorated. In this article, a linear active disturbance rejection controller with reference differential feedforward and cascade linear extended state observer (ADRC-RDCO) is proposed to deal with unknown modeling error and the unknown dynamics of the interface converter. In this strategy, a cascaded linear extended state observer is introduced to cope with the steady-state offset in the disturbance estimation error, so as to implement the accurate reconstruction of the disturbance state. Furthermore, a control law with RDF is applied to offset a portion of the tracking error of the given signal to achieve the purpose of optimizing the tracking accuracy of the given signal. Then, the tracking performance and stability of ADRC-RDCO are analyzed theoretically. On the basis of discussing the relationship between dynamic characteristics and control parameters, a parameter configuration method is proposed. Finally, the proposed ADRC-RDCO technology was verified on the 40 kW microgrid platform.
1 June 2022 in IEEE Transactions on Industrial Electronics
In a microgrid, the development and utilization of renewable energy generations are usually completed by dc–dc interface converters. Nonetheless, it is difficult to continuously output high-quality electrical energy under various uncertain interferences. With this, in this article, a modified linear active disturbance rejection control scheme is proposed to handle these deficiencies. In this scheme, a correction function is introduced to cope with the overall disturbance reconstruction deviation so as to realize the timely and accurate estimation. The proposed strategy is able to treat the unknown dynamics and the external disturbance as the overall disturbance through a single structure, alongside the plant is regulated by an improved control law with reference-signal differential feedforward to optimize the traceability for the reference signal. Through performance analysis, the difference between the proposed scheme and the conventional one is discussed. Additionally, the correspondence between controller parameters and operation characteristics is analyzed theoretically so as to provide guidance for parameters adjustment. Finally, a 40-kW test platform is built, and experimental results are presented to verify the significance and correctness of the proposed approach.
1 April 2019 in IEEE Transactions on Industrial Electronics
A novel high conversion ratio bidirectional C-dual transformers-LC (CDT-LC) resonant DC-DC converter is proposed in this paper. Based on the traditional LLC, an auxiliary transformer and an extra resonant capacitance are employed in CDT-LC structure. It not only harvests high efficiency but exhibits a good voltage gain feature. Especially for the case of light load, CDT-LC still harvests a high efficiency, compared with traditional converters. Also, it can achieves a fast gain reduction when the switching frequency is higher than resonant frequency. In this paper, the operating principles of the converter are analyzed in both bi-directional operation modes. In additional, its dual-transformers structure feature and voltage gain characteristics are discussed in details. Furthermore, the parameter design method is provided. Moreover, the loss breakdown for the converter is given in details. At last, a 2.5kW prototype is established to verify the performance of the CDT-LC converter, and its maximum efficiency reaches 97%.
10 April 2023 in IEEE Transactions on Industrial Informatics
As the cornerstone of adjusting microgrid output, the electrical load interface unit is difficult to continuously output desired dynamics under various uncertainties. To handle the problem, a variable form linear active disturbance rejection control (VFLADRC), including extended state differential compensation, is proposed for load interface unit according to the separating response. In this technology, the extended state differential is embedded in the linear extended state observer (LESO) to construct a modified LESO, alongside the control law is generated via a feedforward way. By doing this, the attenuation capability of generalized disturbance response in the system output is improved, thereby optimizing output dynamics. In addition, the stability and output characteristics of the studied scheme are theoretically investigated. It is revealed that the electrical load interface unit with VFLADRC exhibits a higher level of robustness. Finally, comparative experiments are conducted on a 40-kW test platform, which validates the correctness of the analysis and the superiority of the proposed approach.