Xiaoyong Ma

Xiaoyong Ma


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
LTLong Tao
Long Tao
PWPing Wang
Ping Wang
XMXiaoyong Ma
Xiaoyong Ma
YWYi-Feng Wang
Yi-Feng Wang
HSHuaidong Shi
Huaidong Shi
In a microgrid, the development and utilization of renewable energy generations are usually completed by dc–dc interface converters. Nonetheless, it is difficult to continuously output high-quality electrical energy under various uncertain interferences. With this, in this article, a modified linear active disturbance rejection control scheme is proposed to handle these deficiencies. In this scheme, a correction function is introduced to cope with the overall disturbance reconstruction deviation so as to realize the timely and accurate estimation. The proposed strategy is able to treat the unknown dynamics and the external disturbance as the overall disturbance through a single structure, alongside the plant is regulated by an improved control law with reference-signal differential feedforward to optimize the traceability for the reference signal. Through performance analysis, the difference between the proposed scheme and the conventional one is discussed. Additionally, the correspondence between controller parameters and operation characteristics is analyzed theoretically so as to provide guidance for parameters adjustment. Finally, a 40-kW test platform is built, and experimental results are presented to verify the significance and correctness of the proposed approach.

10 April 2023 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
LTLong Tao
Long Tao
PWPing Wang
Ping Wang
XMXiaoyong Ma
Xiaoyong Ma
YWYi-Feng Wang
Yi-Feng Wang
XZXuesong Zhou
Xuesong Zhou
As the cornerstone of adjusting microgrid output, the electrical load interface unit is difficult to continuously output desired dynamics under various uncertainties. To handle the problem, a variable form linear active disturbance rejection control (VFLADRC), including extended state differential compensation, is proposed for load interface unit according to the separating response. In this technology, the extended state differential is embedded in the linear extended state observer (LESO) to construct a modified LESO, alongside the control law is generated via a feedforward way. By doing this, the attenuation capability of generalized disturbance response in the system output is improved, thereby optimizing output dynamics. In addition, the stability and output characteristics of the studied scheme are theoretically investigated. It is revealed that the electrical load interface unit with VFLADRC exhibits a higher level of robustness. Finally, comparative experiments are conducted on a 40-kW test platform, which validates the correctness of the analysis and the superiority of the proposed approach.

17 May 2023 in Energies
Verified
Journal Article
Open access
PDF file
WLWei Li
Wei Li
RJRuixin Jin
Ruixin Jin
XMXiaoyong Ma
Xiaoyong Ma
GZGuozun Guo Zhang
Guozun Guo Zhang
The coordination between a hybrid energy storage system (HESS) and photovoltaic (PV) power station can significantly reduce grid-connected PV power fluctuations. This study proposes a HESS capacity optimal allocation method considering the grid-connected PV requirements. Firstly, based on the power fluctuation requirements in the PV power station grid-connected regulations, the maximum power point tracking working point switching control is performed for the PV power station, from which the grid-connected PV power and HESS power are obtained. Then, a capacity optimal allocation method and frequency division energy management strategy (EMS) for HESS is proposed to find the energy response and power response of each energy storage source. Furthermore, a multi-objective optimization function with HESS cutoff frequency as the independent variable is constructed, and the input cost of HESS and the life loss of the lithium battery are optimized. Finally, the overall strategy is compared and analyzed under the scenarios of three typical PV power fluctuations. Simulation results show that the control strategy has a good smoothing effect on PV power fluctuations. From the perspective of the annual comprehensive input cost, HESS realizes the optimal capacity allocation when the cutoff frequency is 0.0066 Hz.

6 May 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
XMXiaoyong Ma
Xiaoyong Ma
PWPing Wang
Ping Wang
YWYi-Feng Wang
Yi-Feng Wang
LTLong Tao
Long Tao
PCPengyu Cheng
Pengyu Cheng
To achieve the global optimization of efficiency and power density of interleaved buck/boost converter (IBBC) for transportation electrification, a numerical optimization method is proposed based on the penalty and barrier theory. In this method, converter volume is the optimization objective, and efficiency and flux density are the constraints. To formulate the optimization objective and constraints, comprehensive modeling for IBBC is conducted, which decouples master–slave relationships among variables in the modeling process. Then, the penalty and barrier theory is performed on the optimization objective and constraints and an integrated optimization function is established, thus converting the constrained numerical optimization problem to an unconstrained one. Hereafter, a modified backtracking search method is employed for the minimization of the integrated optimization function, and Pareto fronts of efficiency and volume are obtained. Finally, a 60-kW IBBC converter was constructed and the power density reaches 9.65 kW/L, whereas the highest efficiency is 98.6%. Compared with an unoptimized converter, efficiency and power density are improved by 0.3% and 0.65 kW/L, respectively.

28 June 2024 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
NLNingyi Liang
Ningyi Liang
DLDonghui Li
Donghui Li
YWYi-Feng Wang
Yi-Feng Wang
XMXiaoyong Ma
Xiaoyong Ma
JZJian Zhou
Jian Zhou
LTLong Tao
Long Tao
Maintaining bus voltage stability is a central challenge in DC microgrids (MG). This paper introduces a decentralized adaptive energy-shaping approach(DEC) that seamlessly merges constant voltage and droop mode controls, ensuring the comprehensive large-signal stability of the MG. Central to the DEC’s architecture is its stratification of the MG into autonomous Distributed Unit(DU) subsystems. By utilizing a nonlinear observer, this strategy effectively recognizes the electrical interactions among individual DU subsystems, obviating auxiliary output current sensors.This structured approach breaks down the intricate stability challenges of the DC microgrid into more manageable sections. These sections are carefully designed to address estimated couplings and reinforce each DU subsystem’s resilience. The introduced stabilization method, inspired by the passivity-based port-controlled Hamiltonian (pcH) system theory, adopts a passive control damping mechanism coupled with a dynamically adjusted interconnection coefficient. This ensures a smooth stability of DU subsystems, even when faced with significant disturbances. Rigorous theoretical analyses, underpinned by the Lyapunov theorem, corroborate the systemic stability conferred by the DEC design. Furthermore, it demonstrates robustness against unforeseen input voltage variations. Simulations and experiments demonstrate that the proposed control approach accelerates system recovery and broadens the stability margin.

20 January 2025 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
YWYi-Feng Wang
Yi-Feng Wang
ZWZhongda Wang
Zhongda Wang
XMXiaoyong Ma
Xiaoyong Ma
HCHan Cui
Han Cui
JZJian Zhou
Jian Zhou
HSHuaidong Shi
Huaidong Shi
Nowadays, interleaved boost converter (IBC) is widely used in electric vehicle on-board power supplies, which puts forward high requirements for the efficiency and power density of the converter due to high power and limited interior space. Consequently, a three-phase coupled inductor with ladder magnetic core is adopted in this paper and a multi-objective optimization approach based on genetic algorithm (GA) is proposed for converter efficiency and coupled inductor volume. Firstly, the comprehensive objective function and corresponding constraint condition are formulated for the coupled inductor structure to facilitate global optimization. During the modeling process, a source controlled by the inductor voltage is introduced into the magnetic reluctance model to analyze AC magnetic flux. On this foundation, GA is employed to optimize the objective function, which improves the optimization efficiency significantly and the Pareto front of converter efficiency and coupled inductor volume can be obtained according to the optimization results. Finally, an experimental prototype of 30kW is established with a power density of 22kW/L and a maximum efficiency of 98.6%. Compared with non-coupled inductor, the volume is reduced by 43.8% and the power density is increased by 12.8%.