Scanning probe microscopy (SPM) represents a powerful tool that, in the past 30 years, has allowed for the investigation of material surfaces in unprecedented ways at the nanoscale level. However, SPM has shown very little capability for depth penetration, which several nanotechnology applications require. Subsurface imaging has been achieved only in a few cases, when subsurface features influence the physical properties of the surface, such as the electronic states or the heat transfer. Ultrasonic force microscopy (UFM), an adaption of the contact mode atomic force microscopy, can dynamically measure the stiffness of the elastic contact between the probing tip and the sample surface. In particular, UFM has proven highly sensitive to the near-surface elastic field in non-homogeneous samples. In this paper, we present an investigation of two-dimensional (2D) materials, namely flakes of graphite and molybdenum disulphide placed on structured polymeric substrates. We show that UFM can non-destructively distinguish suspended and supported areas and localise defects, such as buckling or delamination of adjacent monolayers, generated by residual stress. Specifically, UFM can probe small variations in the local indentation induced by the mechanical interaction between the tip and the sample. Therefore, any change in the elastic modulus within the volume perturbed by the applied load or the flexural bending of the suspended areas can be detected and imaged. These investigation capabilities are very promising in order to study the buried interfaces of nanostructured 2D materials such as in graphene-based devices.
With the increasing interest in the potential benefits of nanotechnologies, concern is still growing that they may present emerging risks for workers. Various strategies have been developed to assess the exposure to nano-objects and their agglomerates and aggregates (NOAA) in the workplace, integrating different aerosol measurement instruments and taking into account multiple parameters that may influence NOAA toxicity. The present study proposes a multi-metric approach for measuring and sampling NOAA in the workplace, applied to three case studies in laboratories each dedicated to materials with different shapes and dimensionalities: graphene, nanowires, and nanoparticles. The study is part of a larger project with the aim of improving risk management tools in nanomaterials research laboratories. The harmonized methodology proposed by the Organization for Economic Cooperation and Development (OECD) has been applied, including information gathering about materials and processes, measurements with easy-to-use and hand-held real-time devices, air sampling with personal samplers, and off-line analysis using scanning electron microscopy. Significant values beyond which an emission can be attributed to the NOAA production process were identified by comparison of the particle number concentration (PNC) time series and the corresponding background levels in the three laboratories. We explored the relations between background PNC and microclimatic parameters. Morphological and elemental analysis of sampled filters was done to identify possible emission sources of NOAA during the production processes: rare particles, spherical, with average diameter similar to the produced NOAA were identified in the nanoparticles laboratory, so further investigation is recommended to confirm the potential for worker exposure. In conclusion, the information obtained should provide a valuable basis for improving risk management strategies in the laboratory at work.
The operation of graphene-based nanoelectromechanical systems (NEMS) crucially depends on the local mechanical characteristics of the graphene drum resonator. In particular, inhomogeneity in the residual strain (pre-strain) of the graphene membrane may affect the vibration dynamics as well as the energy dissipation. Despite its importance, achieving a precise local mapping of the pre-strain of a graphene membrane remains challenging. Here, we correlate scanning-probe force microscopy and Raman spectroscopy to map the local mechanical properties of circular monolayer-graphene drums. At odds with other techniques, we obtain maps of the membrane pre-strain with nanometric resolution and measure the effective Young’s modulus in a non-invasive way. Moreover, we show that the common topographic artefacts stemming from tip-induced deformations can be precisely corrected using the information derived from force-spectroscopy data. As a result, the local map of the pre-strain can be correlated with the true morphology of the graphene drum. Our analysis demonstrates that graphene resonators can be characterized by a non-flat morphology and a non-uniform pre-strain distribution, as a consequence of complex boundary conditions at the edge of the membrane and in correlation with local material defects. Since these non-ideal features are strictly related to the growth and the fabrication procedures, our method can provide a useful screening tool for the development of 2D materials-based NEMSs.
We investigate nanoscale local anodic oxidation (LAO) on hydrogen-intercalated graphene grown by controlled sublimation of silicon carbide (SiC). Scanning probe microscopy was used as a lithographic and characterization tool in order to investigate the local properties of the nanofabricated structures. The anomalous thickness observed after the graphene oxidation process is linked to the impact of LAO on the substrate. Micro-Raman ( μ -Raman) spectroscopy was employed to demonstrate the presence of two oxidation regimes depending on the applied bias. We show that partial and total etching of monolayer graphene can be achieved by tuning the bias voltage during LAO. Finally, a complete compositional characterization was achieved by scanning electron microscopy and energy dispersive spectroscopy.