7 May 2020 in Energies
Verified
Journal Article
Open access
PDF file
ALAndrzej Lange
Andrzej Lange
GRGrzegorz Redlarski
Grzegorz Redlarski
This article presents a method for selecting the elements of a C-type filter working with a conventional LC-type filter for compensating reactive power and filtering out higher harmonics generated by arc furnaces and ladle furnaces. The study was conducted in a steel mill supplied by a 110 kV transmission system, where higher harmonic currents and nonlinear loads were measured. A series of computer simulations were performed under various operating conditions, and an algorithm for selecting the parameters of a third-order C-type filter (for suppressing the second harmonic) and two second-order LC-type filters (for suppressing the third harmonic) was proposed. The filtering system was tested in an arc furnace with the highest rated power, and harmonics in the current spectrum were evaluated. The results of the measurements were used to analyze the effectiveness of the compensation system comprising two passive C-type and LC-type filters at different system configurations. C-type filters significantly influenced current harmonics. The influence of the changes in the number of arc furnace transformers on the true Root Mean Square (RMS) of the currents injected into the 110 kV transmission system and on the voltages of the 110 kV busbars was discussed.

13 July 2020 in Energies
Verified
Journal Article
Open access
PDF file
Dawid BułaDawid Buła
Dawid Buła
Dariusz GrabowskiDariusz Grabowski
Dariusz Grabowski
ALAndrzej Lange
Andrzej Lange
Marcin MaciążekMarcin Maciążek
Marcin Maciążek
MPMarian Pasko
Marian Pasko
Network working conditions are influenced noticeably by the connection of renewable energy sources to distribution networks. This becomes more and more important due to the increase in renewable energy source penetration over the last few years. This in turn can lead to a mass effect. As a result, the classical open network model with simple unidirectional direction of energy flow has been replaced with an active model that includes many local energy sources. This paper deals with the analysis of long- and short-term changes in power and energy generated by three types of renewable energy sources with similar rated power and which operate in the same region (i.e., located no more than tens of kilometers away). The obtained results can be a starting point for a broader evaluation of the influence of renewable energy sources on power quality in power systems, which can be both positive (supply reliability) and negative (voltage fluctuations and higher harmonics in current and voltage waveforms). It is important not only to correctly place but also to assure the diversity of such sources as it has been confirmed by the source variability coefficient. The long-term analysis allows us also to estimate the annual repeatability of energy production and, furthermore, the profitability of investment in renewable sources in a given region.

16 April 2024 in Energies
Verified
Journal Article
Open access
PDF file
SŁSebastian Łapczyński
Sebastian Łapczyński
MSMichał Szulborski
Michał Szulborski
Łukasz KolimasŁukasz Kolimas
Łukasz Kolimas
PSPrzemysław Sul
Przemysław Sul
MOMaciej Owsiński
Maciej Owsiński
ALAndrzej Lange
Andrzej Lange
This paper concerns the effects of electrodynamic forces that act on current paths that are part of high-grade industrial distribution switchgear. This work is composed of experimental and simulation sections. In the experimental section, the short-circuit tests are presented and the occurrence of electrodynamic forces are shown in a visible way. The formation of electrodynamic forces in the current circuits of electrical energy distribution systems is related to the flow of high currents, but mostly it is related to short-circuit currents. In order to highlight these phenomena, the detailed specification of the parameters during tests is displayed. In the simulation section, the physical phenomenon of electrodynamic forces is being captured by employing a detailed real-scale model of switchgear and current paths. Therefore, the authors proposed employment of the FEM (finite element method) in order to obtain values of electrodynamic forces acting on the current paths by executing the detailed 3D coupled simulation. The analysis of the results and aftermath effects of their interactions provided interesting conclusions that concerned the operation of such power distribution layouts in critical short-circuit conditions.

14 April 2023 in Energies
Verified
Journal Article
Open access
PDF file
ŁKŁukasz Kozarek
Łukasz Kozarek
HCHubert Cichecki
Hubert Cichecki
MBMateusz Bogacki
Mateusz Bogacki
MTMykhailo Tyryk
Mykhailo Tyryk
Michał SzulborskiMichał Szulborski
Michał Szulborski
MOMaciej Owsiński
Maciej Owsiński
This paper focuses on determining the effects of short-circuit current values on the operation of high-voltage substations. The analyses performed focused on the dynamic and thermal effects on the short-circuit current for different input data configurations. The analyses of the dynamic effects of short-circuit current were performed in two ways. First, calculations were executed using the procedures contained in “IEC 60865-1:2012 Short-circuit currents, calculations of the effects of short-circuit currents. Part 1: Definitions and calculation methods”. Analytic calculations were accomplished for different values of the initial three-phase short-circuit current, the type of short circuit, the static tension force of the conductors, the stiffness of the structure and the methods of attaching the lashing chains. Secondly, the same analysis was performed using PRIMTECH 3D software. The connections were modeled in computer software, for which the calculations were implemented according to normative recommendations. After obtaining the results, an analysis was performed using the model based on the input data. Performing the analysis in two ways made it possible to compare the results with each other and develop conclusions. An analysis of the thermal effects of the short-circuit current was also provided. The results of the calculations showed that the choice of conductor cross sections according to the value of the initial short-circuit current was correct. Particular attention has been paid to rigid conductors and flexible conductors, which are directly affected by the short circuit and have an impact on the selection of the complete equipment for the high-voltage switchgear.

1 January 2020 in PRZEGLĄD ELEKTROTECHNICZNY
Verified
Journal Article
Closed access
ALAndrzej Lange
Andrzej Lange
MPMarian Pasko
Marian Pasko
This paper presents the results of a five-year study of a 1 MW photovoltaic power station in the Warmia and Mazury Province. The research involved measurements of active energy, currents, voltages, active, reactive and apparent power and higher harmonics of currents and voltages. The operation of this plant was analysed in terms of electricity produced and active power generated to the power grid in individual years, months and days. The analysis concerning the impact of the plant on the power grid in terms of the quality of electricity supplied included the results of three-day measurements of not only active, reactive and apparent power, but also of higher harmonics of currents generated to power grids on the low-voltage side, the results of which were recorded every second.

21 September 2018 in ITM Web of Conferences
Verified
Journal Article
Open access
ALAndrzej Lange
Andrzej Lange
MPMarian Pasko
Marian Pasko
The article presents the regulations and standards relating to the quality of electricity, with special emphasis on higher current and voltage harmonics in high-voltage, medium-voltage and low-voltage power grids and the power factor (PF). The parameters defining the quality of electricity consumed by modern LED bulbs for lighting homes, industrial premises such as offices and production halls, as well as roads and yards were measured and analyzed. The current waveforms for LED lights were presented upon connection to the power grid.