In this work, we have studied how gas accumulates in an industrial centrifugal pump under various steady-state two-phase flow conditions. Thereby, we considered both horizontal and vertical pump installation positions. Phase fractions within the impeller region of the pump have been quantitatively disclosed using high-resolution gamma-ray computed tomography (HireCT) and applying time-averaged rotation-synchronized CT scanning technique. The study was made for inlet volumetric gas flow rates between 0% and 5%. To account for different inlet flow conditions, which are assumed to occur during unwanted gas entrainment by hollow vortices, we produced disperse and swirling gas–liquid inlet flows. In this way, the influence of inlet flow boundary conditions on the pump performance as well as gas fraction distributions and gas holdup within the impeller wheel region could be successfully analyzed and compared with respect to the impeller alignment. It was shown that the installation position offers only a minor effect on the pump performance in comparison to the inlet flow conditions. In addition, for the first time, thin gas films at the pressure side of the impeller wheel blades could be visualized in an industrial centrifugal pump.
1 December 2015 in Flow Measurement and Instrumentation
In this paper, a compa ct high-resolution gamma-ray Computed Tomography (CompaCT) measurement system for multiphase flow studies and tomographic imaging of technical objects is presented. Its compact and robust design makes it particularly suitable for studies on industrial facilities and outdoor applications. Special care has been given to thermal ruggedness, shock resistance, and radiation protection. Main components of the system are a collimated 137Cs isotopic source, a thermally stabilised modular high-resolution gamma-ray detector arc with 112 scintillation detector elements, and a transportable rotary unit. The CompaCT allows full CT scans of objects with a diameter of up to 130 mm and can be operated with any tilting angle from 0° (horizontal) to 90° (vertical).
Gas entrainment into centrifugal pumps decreases pump performance and may raise safety issues, e.g., through insufficient cooling. Although there is some phenomenological knowledge in the form of correlations between operating parameters and pump performance, a further understanding via direct observation of the gas–liquid mixture was so far not possible. In this paper, we demonstrate the capability of ultrafast X-ray computed tomography (UFXCT) to disclose gas–liquid two-phase flow dynamics in the impeller region of a centrifugal pump mockup. Experiments were performed for gas injection at impeller speeds between 1300 rpm and 1600 rpm. We analyzed the X-ray image sequences with respect to characteristics of the gas distribution and compared them with time-averaged image data of a real pump obtained earlier with gamma-ray computed tomography (CT).