In this work, we have studied how gas accumulates in an industrial centrifugal pump under various steady-state two-phase flow conditions. Thereby, we considered both horizontal and vertical pump installation positions. Phase fractions within the impeller region of the pump have been quantitatively disclosed using high-resolution gamma-ray computed tomography (HireCT) and applying time-averaged rotation-synchronized CT scanning technique. The study was made for inlet volumetric gas flow rates between 0% and 5%. To account for different inlet flow conditions, which are assumed to occur during unwanted gas entrainment by hollow vortices, we produced disperse and swirling gas–liquid inlet flows. In this way, the influence of inlet flow boundary conditions on the pump performance as well as gas fraction distributions and gas holdup within the impeller wheel region could be successfully analyzed and compared with respect to the impeller alignment. It was shown that the installation position offers only a minor effect on the pump performance in comparison to the inlet flow conditions. In addition, for the first time, thin gas films at the pressure side of the impeller wheel blades could be visualized in an industrial centrifugal pump.
1 December 2015 in Flow Measurement and Instrumentation
Gas entrainment into centrifugal pumps decreases pump performance and may raise safety issues, e.g., through insufficient cooling. Although there is some phenomenological knowledge in the form of correlations between operating parameters and pump performance, a further understanding via direct observation of the gas–liquid mixture was so far not possible. In this paper, we demonstrate the capability of ultrafast X-ray computed tomography (UFXCT) to disclose gas–liquid two-phase flow dynamics in the impeller region of a centrifugal pump mockup. Experiments were performed for gas injection at impeller speeds between 1300 rpm and 1600 rpm. We analyzed the X-ray image sequences with respect to characteristics of the gas distribution and compared them with time-averaged image data of a real pump obtained earlier with gamma-ray computed tomography (CT).
This paper presents results of the development and application of a new temperature grid sensor based on the wire-mesh sensor principle. The grid sensor consists of a matrix of 256 Pt1000 platinum chip resistors and an associated electronics that measures the grid resistances with a multiplexing scheme at high speed. The individual sensor elements can be spatially distributed on an object surface and measure transient temperature distributions in real time. The advantage compared with other temperature field measurement approaches such as infrared cameras is that the object under investigation can be thermally insulated and the radiation properties of the surface do not affect the measurement accuracy. The sensor principle is therefore suited for various industrial monitoring applications. Its applicability for surface temperature monitoring has been demonstrated through heating and mixing experiments in a vessel.