Hyunwoo Jeong

Prof. Dr. Hyunwoo Jeong

Eulji university, Seongnam, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
BKBae-Guen Kim
Bae-Guen Kim
SKSeong-Hyeon Kang
Seong-Hyeon Kang
CPChanrok Park
Chanrok Park
HJHyunwoo Jeong
Hyunwoo Jeong
YLYoungjin Lee
Youngjin Lee
Although conventional denoising filters have been developed for noise reduction from digital images, these filters simultaneously cause blurring in the images. To address this problem, we proposed the fast non-local means (FNLM) denoising algorithm which would preserve the edge information of objects better than conventional denoising filters. In this study, we obtained thoracic computed tomography (CT) images from a male adult mesh (MASH) phantom modeled by computer and a five-year-old phantom to perform both the simulation study and the practical study. Subsequently, the FNLM denoising algorithm and conventional denoising filters, such as the Gaussian, median, and Wiener filters, were applied to the MASH phantom image adding Gaussian noise with a standard deviation of 0.002 and practical CT images. Finally, the results were compared quantitatively in terms of the coefficient of variation (COV), contrast-to-noise ratio (CNR), peak signal-to-noise ratio (PSNR), and correlation coefficient (CC). The results showed that the FNLM denoising algorithm was more efficient than the conventional denoising filters. In conclusion, through the simulation study and the practical study, this study demonstrated the feasibility of the FNLM denoising algorithm for noise reduction from thoracic CT images.

20 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
ENEzekiel Edward Nettey-Oppong
Ezekiel Edward Nettey-Oppong
RMRiaz Muhammad
Riaz Muhammad
EAEmmanuel Ackah
Emmanuel Ackah
HYHojun Yang
Hojun Yang
AAAhmed Ali
Ahmed Ali
SCSeung Ho Choi
Seung Ho Choi
This study presents the fabrication of a sustainable flexible humidity sensor utilizing chitosan derived from mealworm biomass as the primary sensing material. The chitosan-based humidity sensor was fabricated by casting chitosan and polyvinyl alcohol (PVA) films with interdigitated copper electrodes, forming a laminate composite suitable for real-time, resistive-type humidity detection. Comprehensive characterization of the chitosan film was performed using Fourier-transform infrared (FTIR) spectroscopy, contact angle measurements, and tensile testing, which confirmed its chemical structure, wettability, and mechanical stability. The developed sensor exhibited a broad range of measurements from 6% to 97% relative humidity (RH), a high sensitivity of 2.43 kΩ/%RH, and a rapid response time of 18.22 s with a corresponding recovery time of 22.39 s. Moreover, the chitosan-based humidity sensor also demonstrated high selectivity for water vapor when tested against various volatile organic compounds (VOCs). The superior performance of the sensor is attributed to the structural properties of chitosan, particularly its ability to form reversible hydrogen bonds with water molecules. This mechanism was further elucidated through molecular dynamics simulations, revealing that the conductivity in the sensor is modulated by proton mobility, which operates via the Grotthuss mechanism under high-humidity and the packed-acid mechanism under low-humidity conditions. Additionally, the chitosan-based humidity sensor was further seamlessly integrated into an Internet of Things (IoT) framework, enabling wireless humidity monitoring and real-time data visualization on a mobile device. Comparative analysis with existing polymer-based resistive-type sensors further highlighted the superior sensing range, rapid dynamic response, and environmental sustainability of the developed sensor. This eco-friendly, biomass-derived, eco-friendly sensor shows potential for applications in environmental monitoring, smart agriculture, and industrial process control.

21 November 2024 in Materials
Verified
Journal Article
Open access
PDF file
ENEzekiel Edward Nettey-Oppong
Ezekiel Edward Nettey-Oppong
RMRiaz Muhammad
Riaz Muhammad
AAAhmed Ali
Ahmed Ali
HJHyunwoo Jeong
Hyunwoo Jeong
YSYoung-Seek Seok
Young-Seek Seok
SCSeung Ho Choi
Seung Ho Choi
Bombyx mori silk fibroin is a promising biopolymer with notable mechanical strength, biocompatibility, and potential for diverse biomedical applications, such as tissue engineering scaffolds, and drug delivery. These properties are intrinsically linked to the structural characteristics of silk fibroin, making it essential to understand its molecular stability under varying environmental conditions. This study employed molecular dynamics simulations to examine the structural stability of silk I and silk II conformations of silk fibroin under changes in temperature (298 K to 378 K) and pressure (0.1 MPa to 700 MPa). Key parameters, including Root Mean Square Deviation (RMSD), Root Mean Square Fluctuation (RMSF), and Radius of Gyration (Rg) were analyzed, along with non-bonded interactions such as van der Waals and electrostatic potential energy. Our findings demonstrate that both temperature and pressure exert a destabilizing effect on silk fibroin, with silk I exhibiting a higher susceptibility to destabilization compared to silk II. Additionally, pressure elevated the van der Waals energy in silk I, while temperature led to a reduction. In contrast, electrostatic potential energy remained unaffected by these environmental conditions, highlighting stable long-range interactions throughout the study. Silk II’s tightly packed β-sheet structure offers greater resilience to environmental changes, while the more flexible α-helices in silk I make it more susceptible to structural perturbations. These findings provide valuable insights into the atomic-level behavior of silk fibroin, contributing to a deeper understanding of its potential for applications in environments where mechanical or thermal stress is a factor. The study underscores the importance of computational approaches in exploring protein stability and supports the continued development of silk fibroin for biomedical and engineering applications.

4 April 2023 in Sensors
Verified
Journal Article
Open access
PDF file
RMRiaz Muhammad
Riaz Muhammad
KHKay Thwe Htun
Kay Thwe Htun
ENEzekiel Edward Nettey-Oppong
Ezekiel Edward Nettey-Oppong
AAAhmed Ali
Ahmed Ali
DJDae Keun Jeon
Dae Keun Jeon
SCSeung Ho Choi
Seung Ho Choi
Pulse oximetry is a non-invasive method for measuring blood oxygen saturation. However, its detection scheme heavily relies on single-point measurements. If the oxygen saturation is measured at a single location, the measurements are influenced by the profile of illumination, spatial variations in blood flow, and skin pigment. To overcome these issues, imaging systems that measure the distribution of oxygen saturation have been demonstrated. However, previous imaging systems have relied on red and near-infrared illuminations with different profiles, resulting in inconsistent ratios between transmitted red and near-infrared light over space. Such inconsistent ratios can introduce fundamental errors when calculating the spatial distribution of oxygen saturation. In this study, we developed a novel illumination system specifically designed for a pulse oximetry imaging system. For the illumination system, we customized the integrating sphere by coating a mixture of barium sulfate and white paint inside it and by coupling eight red and eight near-infrared LEDs. The illumination system created identical patterns of red and near-infrared illuminations that were spatially uniform. This allowed the ratio between transmitted red and near-infrared light to be consistent over space, enabling the calculation of the spatial distribution of oxygen saturation. We believe our developed pulse oximetry imaging system can be used to obtain spatial information on blood oxygen saturation that provides insight into the oxygenation of the blood contained within the peripheral region of the tissue.

KKkyuseok kim
kyuseok kim
NCNuri Chon
Nuri Chon
HJHyunwoo Jeong
Hyunwoo Jeong
YLYoungjin Lee
Youngjin Lee
This study aimed to improve the quality of ultrasound images by modeling an algorithm using a non-local means (NLM) noise-reduction approach to achieve precise quality control and accurate diagnosis of thyroid nodules. An ATS-539 multipurpose phantom was used to scan the dynamic range and gray-scale measurement regions, which are most closely related to the noise level. A convex-type 3.5-MHz frequency probe is used for scanning according to ATS regulations. In addition, ultrasound images of human thyroid nodules were obtained using a linear probe. An algorithm based on the NLM noise-reduction approach was modeled based on the intensity and relative distance of adjacent pixels in the image, and conventional filtering methods for image quality improvement were designed as a comparison group. When the NLM algorithm was applied to the image, the contrast-to-noise ratio and coefficient of variation values improved by 28.62% and 19.54 times, respectively, compared with those of the noisy images. In addition, the image improvement efficiency of the NLM algorithm was superior to that of conventional filtering methods. Finally, the applicability of the NLM algorithm to human thyroid images using a high-frequency linear probe was validated. We demonstrated the efficiency of the proposed algorithm in ultrasound images and the possibility of capturing improved images in the dynamic range and gray-scale region for quality control parameters.

KKKyuseok Kim
Kyuseok Kim
HJHyunwoo Jeong
Hyunwoo Jeong
YLYoungjin Lee
Youngjin Lee
Vein puncture is commonly used for blood sampling, and accurately locating the blood vessel is an important challenge in the field of diagnostic tests. Imaging systems based on near-infrared (NIR) light are widely used for accurate human vein puncture. In particular, segmentation of a region of interest using the obtained NIR image is an important field, and research for improving the image quality by removing noise and enhancing the image contrast is being widely conducted. In this paper, we propose an effective model in which the relative total variation (RTV) regularization algorithm and contrast-limited adaptive histogram equalization (CLAHE) are combined, whereby some major edge information can be better preserved. In our previous study, we developed a miniaturized NIR imaging system using light with a wavelength of 720–1100 nm. We evaluated the usefulness of the proposed algorithm by applying it to images acquired by the developed NIR imaging system. Compared with the conventional algorithm, when the proposed method was applied to the NIR image, the visual evaluation performance and quantitative evaluation performance were enhanced. In particular, when the proposed algorithm was applied, the coefficient of variation was improved by a factor of 15.77 compared with the basic image. The main advantages of our algorithm are the high noise reduction efficiency, which is beneficial for reducing the amount of undesirable information, and better contrast. In conclusion, the applicability and usefulness of the algorithm combining the RTV approach and CLAHE for NIR images were demonstrated, and the proposed model can achieve a high image quality.