Xiaohui Zhao

Dr. Xiaohui Zhao

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2017 in Journal of Alloys and Compounds
Verified
Journal Article
Closed access
XZXiaohui Zhao
Xiaohui Zhao
HLHaitao Li
Haitao Li
KYKe Yang
Ke Yang
SJShuwen Jiang
Shuwen Jiang
HJHongchuan Jiang
Hongchuan Jiang
WZWanli Zhang
Wanli Zhang

1 August 2018 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
HLHao Liu
Hao Liu
SJShuwen Jiang
Shuwen Jiang
XZXiaohui Zhao
Xiaohui Zhao
HJHongchuan Jiang
Hongchuan Jiang
WZWanli Zhang
Wanli Zhang

31 December 2017 in Sensors
Verified
Journal Article
Open access
PDF file
HJHongChuan Jiang
HongChuan Jiang
MMin Huang
Min Huang
YYYibing Yu
Yibing Yu
XTXiaoyu Tian
Xiaoyu Tian
XZXiaohui Zhao
Xiaohui Zhao
KYKun Yu
Kun Yu
In this work, a PdNi thin film hydrogen gas sensor with integrated Pt thin film temperature sensor was designed and fabricated using the micro-electro-mechanical system (MEMS) process. The integrated sensors consist of two resistors: the former, based on Pt film, is used as a temperature sensor, while the latter had the function of hydrogen sensing and is based on PdNi alloy film. The temperature coefficient of resistance (TCR) in both devices was measured and the output response of the PdNi film hydrogen sensor was calibrated based on the temperature acquired by the Pt temperature sensor. The SiN layer was deposited on top of Pt film to inhibit the hydrogen diffusion and reduce consequent disturbance on temperature measurement. The TCR of the PdNi film and the Pt film was about 0.00122/K and 0.00217/K, respectively. The performances of the PdNi film hydrogen sensor were investigated with hydrogen concentrations from 0.3% to 3% on different temperatures from 294.7 to 302.2 K. With the measured temperature of the Pt resistor and the TCR of the PdNi film, the impact of the temperature on the performances of the PdNi film hydrogen sensor was reduced. The output response, response time and recovery time of the PdNi film hydrogen sensors under the hydrogen concentration of 0.5%, 1.0%, 1.5% and 2.0% were measured at 313 K. The output response of the PdNi thin film hydrogen sensors increased with increasing hydrogen concentration while the response time and recovery time decreased. A cycling test between pure nitrogen and 3% hydrogen concentration was performed at 313 K and PdNi thin film hydrogen sensor demonstrated great repeatability in the cycling test.

25 November 2016 in Rare Metals
Verified
Journal Article
Closed access
PDF file
XZXiaohui Zhao
Xiaohui Zhao
YWYi‐Ran Wang
Yi‐Ran Wang
YCYin‐Zhi Chen
Yin‐Zhi Chen
HJHong‐Chuan Jiang
Hong‐Chuan Jiang
WZWan‐Li Zhang
Wan‐Li Zhang

25 March 2017 in Crystals
Verified
Journal Article
Open access
PDF file
XZXiaohui Zhao
Xiaohui Zhao
XLXianguai Liang
Xianguai Liang
SJShuwen Jiang
Shuwen Jiang
WZWanli Zhang
Wanli Zhang
HJHongChuan Jiang
HongChuan Jiang
Due to their small size, extremely fast response, and low cost, refractory metallic thin film thermocouples (TFTCs) are well suited for the surface temperature measurement of hot components. In this study, PtRh films with different amounts of Rhodium (10% and 13%) were deposited with direct current magnetron sputtering and annealed at different temperatures in air. The chemistry, microstructure, and resistivity of the films were investigated. Type S (Pt10%Rh-Pt) and type R (Pt13%Rh-Pt) TFTC were fabricated on alumina substrates. Rhodium segregation at the surface of PtRh film was observed, and the variation of the thermoelectric properties of TFTCs was discussed based on the chemistry and microstructure of PtRh films.

1 June 2017 in Vacuum
Verified
Journal Article
Closed access
XZXiaohui Zhao
Xiaohui Zhao
HLHaitao Li
Haitao Li
YCYinzhi Chen
Yinzhi Chen
HJHongchuan Jiang
Hongchuan Jiang