In this work, a PdNi thin film hydrogen gas sensor with integrated Pt thin film temperature sensor was designed and fabricated using the micro-electro-mechanical system (MEMS) process. The integrated sensors consist of two resistors: the former, based on Pt film, is used as a temperature sensor, while the latter had the function of hydrogen sensing and is based on PdNi alloy film. The temperature coefficient of resistance (TCR) in both devices was measured and the output response of the PdNi film hydrogen sensor was calibrated based on the temperature acquired by the Pt temperature sensor. The SiN layer was deposited on top of Pt film to inhibit the hydrogen diffusion and reduce consequent disturbance on temperature measurement. The TCR of the PdNi film and the Pt film was about 0.00122/K and 0.00217/K, respectively. The performances of the PdNi film hydrogen sensor were investigated with hydrogen concentrations from 0.3% to 3% on different temperatures from 294.7 to 302.2 K. With the measured temperature of the Pt resistor and the TCR of the PdNi film, the impact of the temperature on the performances of the PdNi film hydrogen sensor was reduced. The output response, response time and recovery time of the PdNi film hydrogen sensors under the hydrogen concentration of 0.5%, 1.0%, 1.5% and 2.0% were measured at 313 K. The output response of the PdNi thin film hydrogen sensors increased with increasing hydrogen concentration while the response time and recovery time decreased. A cycling test between pure nitrogen and 3% hydrogen concentration was performed at 313 K and PdNi thin film hydrogen sensor demonstrated great repeatability in the cycling test.
Due to their small size, extremely fast response, and low cost, refractory metallic thin film thermocouples (TFTCs) are well suited for the surface temperature measurement of hot components. In this study, PtRh films with different amounts of Rhodium (10% and 13%) were deposited with direct current magnetron sputtering and annealed at different temperatures in air. The chemistry, microstructure, and resistivity of the films were investigated. Type S (Pt10%Rh-Pt) and type R (Pt13%Rh-Pt) TFTC were fabricated on alumina substrates. Rhodium segregation at the surface of PtRh film was observed, and the variation of the thermoelectric properties of TFTCs was discussed based on the chemistry and microstructure of PtRh films.
A highly sensitive and flexible hydrogen sensor based on organic nanofibers decorated by Pd nanoparticles (NPs) was designed and fabricated for low-concentration hydrogen detection. Pd NPs were deposited on organic nanofiber materials by DC magnetron sputtering. The temperature dependence of the sensitivity at 25 ppm H2 was characterized and discussed, and the maximum response of the sensor increased linearly with increasing measurement temperature. Performances of the hydrogen sensor were investigated with hydrogen concentration ranging from 5 ppm to 50 ppm. This sensor exhibits high sensitivity, with the response up to 6.55% for H2 as low as 5 ppm, and the output response of the hydrogen sensor increased linearly with the square root of hydrogen concentration. A cycling test between pure nitrogen and 25 ppm hydrogen concentration was performed, and the hydrogen sensor exhibited excellent consistency.
19 April 2014 in Acta Metallurgica Sinica (English Letters)
The energetic igniters through integrating Al/NiO nanolaminates on Cr film bridges have been investigated in this study. The microstructures demonstrate well-defined geometry and sharp interfaces. The depth profiles of the X-ray photoelectron spectroscopy of Al/NiO nanolaminates annealed at 550 °C with a bilayer thickness of 250 nm show that the interdiffusion between the Al layer and NiO layer has happened and the annealing temperature cannot provide enough energy to make the diffusion process much more complete. The electrical explosion characteristics employing a capacitor discharge firing set at the optimized charging voltage of 40 V show that the flame duration time is about 700 μs, and an excellent explosion performance is obtained for (Al/NiO)n/Cr igniters with a bilayer thickness of 1000 nm.