Understanding the recharge–discharge system of a catchment is key to the efficient use and effective management of groundwater resources. The present study focused on the estimation of groundwater recharge using Soil Moisture Balance (SMB) and Baseflow Separation (BFS) methods in the Gilgel Gibe catchment where water demand for irrigation, domestic, and industrial purposes is dramatically increasing. The demand for groundwater and the existing ambitious plans to respond to this demand will put a strain on the groundwater resource in the catchment unless prompt intervention is undertaken to ensure its sustainability. Ground-based hydrometeorological 36-years data (1985 to 2020) from 17 stations and satellite products from CHIRPS and NASA/POWER were used for the SMB method. Six BFS methods were applied through the Web-based Hydrograph Analysis Tool (WHAT), SepHydro, BFLOW, and Automated Computer Programming (PART) to sub-catchments and the main catchment to estimate the groundwater recharge. The streamflow data (discharge) obtained from the Ministry of Water and Energy were the main input data for the BFS methods. The average annual recharge of groundwater was estimated to be 313 mm using SMB for the years 1985 to 2020 and 314 mm using BFS for the years 1986 to 2003. The results from the SMB method revealed geographical heterogeneity in annual groundwater recharge, varying from 209 to 442 mm. Significant spatial variation is also observed in the estimated annual groundwater recharge using the BFS methods, which varies from 181 to 411 mm for sub-catchments. Hydrogeological conditions of the catchment were observed, and the yielding capacity of existing wells was assessed to evaluate the validity of the results. The recharge values estimated using SMB and BFS methods are comparable and hydrologically reasonable. The findings remarkably provide insightful information for decision-makers to develop effective groundwater management strategies and to prioritize the sub-catchments for immediate intervention to ensure the sustainability of groundwater.
Water loss has become increasingly critical as the severity of the water shortage situation has grown in recent decades. One of the options for reducing water loss in urban water distribution networks is pressure management. The study aimed to evaluate and optimize the existing water distribution system in the city. The proposed methodology is an interactive combination process between an optimization algorithm and WaterGEMS V8i to evaluate the performance of the distribution system. It was observed that, 43.80% of nodes (15–60 mH2O), 5.10% of nodes (15 mH2O), and 51.10% of nodes (>60 mH2O) received pressure during peak hour demand. During low demand periods, only 4.4% of nodes (15–60 mH2O) and 95.60% of nodes (>60 mH2O) received pressure. The water age simulation results revealed that, 51.70% of the pipes were received water age <4.8 h, whereas the other 48.3% of the pipes were received water age <8.6 h during peak hour demand. During low demand periods, 45.58% of the pipes had a water age of less than 4.8 h while the other 54.42% of the pipes had water age of 4.8–20 h. The optimization result showed that after optimization, 4.4% of the nodes with optimum pressure increased to 75.18%, and 95.6% of the nodes decreased to 24.82%. Changing the size of the pipe based on the optimization result, and dividing an area into different pressure zones (adding more reservoirs at the far end of the distribution system) are all ways to improve or upgrade the distribution system.
The sustainable use and management of groundwater resources is a challenging issue due to population growth and climate change. Accurate quantification of groundwater recharge is a basic requirement for effective groundwater resource management, yet it is still lacking in many areas around the world. The study was designed to estimate recharge to groundwater from natural rainfall in the Gilgel Gibe and Dhidhessa catchments in southwestern Ethiopia, employing the water table fluctuation (WTF) and chloride mass balance (CMB) techniques. These methods are being applied for the first time in the study area and have not previously been used in these catchments. Given the region’s data scarcity, a community-based data collection program was implemented and supplemented with additional field measurements and secondary data sources. Groundwater level, spring discharge, and rainfall were monitored over the 2022/2023 hydrological year. Groundwater level fluctuations were found to be influenced by topography and rainfall patterns, reaching 8.2 m in amplitude in the upstream part of the catchments. Chloride concentrations were determined in groundwater samples collected from hand-dug wells and springs, and rainwater was also collected. Rainwater exhibited a mean chloride concentration of 2.46 mg/L, while groundwater chloride concentrations ranged from 3 mg/L to 36.99 mg/L. The estimated recharge rates varied spatially, ranging from 170 to 850 mm/year using the CMB method (11% to 55% of annual rainfall, mean recharge rate of 454 mm/year) and from 76 to 796 mm/year using the WTF method (4% to 43% of annual rainfall, mean recharge rate of 439 mm/year). Notably, recharge estimates were lowest downstream in the lowland areas and highest upstream in the highland regions. Rainfall amount, local lithology, and topography were identified as major influences on groundwater recharge across the study area. Both CMB and WTF methods were deemed applicable in the volcanic aquifers, provided that all the respective assumptions are followed. This study significantly contributes to the groundwater dataset for the region, in addition to recharge estimation and the research conclusions, emphasizing the importance of long-term monitoring and time series analysis of chloride data to reduce uncertainties. The work serves as a valuable reference for researchers, policymakers, and regional water resource managers.
The sustainable management of groundwater in the Jimma area is complicated by a lack of comprehensive studies on its chemical makeup and the geochemical processes influencing its hydrochemistry. This research aims to fill that gap by examining 51 groundwater samples from various sources, including deep groundwaters, shallow groundwaters, hand-dug well groundwaters, surface waters, and springs within the area primarily consisting of complex volcanic rocks. The goal is to describe the hydrogeochemical characteristics and determine the key processes affecting groundwater composition in this volcanic area. The study identifies clear patterns in cation and anion concentrations. For deep groundwaters, the average cation concentration is ranked as Na+ > Ca2+ > Mg2+ > K+, while shallow groundwaters, hand-dug well groundwaters, surface waters, and springs show a ranking of Ca2+ > Na+ > Mg2+ > K+. The major anions are typically ordered as HCO3− > NO3− > Cl− > SO42−. The quantitative hydrogeochemical analysis indicates that the freshwater types in the region are primarily Ca-HCO3 and Ca-Mg-HCO3, with some highly mineralized Na-HCO₃ waters also detected. The weathering of silicate minerals mainly drives the geochemical processes affecting groundwater chemistry. An increase in mineralization, suggested by saturation indices, points to a longer residence time underground, with deep groundwaters exhibiting the highest saturation levels and springs the lowest. This mineralization is especially significant for Mg-silicates and carbonates. Stability diagrams for feldspar minerals further demonstrate groundwater evolution along flow paths, revealing that shallow systems are in equilibrium with minerals like gibbsite, whereas deeper systems achieve stability with albite, Ca-montmorillonite, and microcline. Higher CO2 levels (10−1.5 to 100.5 atm), likely from mantle-magma degassing, add more HCO3− to the deeper aquifers. This study offers the first thorough characterization of the groundwater composition in the Jimma area and provides important insights into the Jimma area’s hydrogeochemical development, establishing a basis for enhanced groundwater management within this intricate volcanic aquifer system.
27 February 2023 in Environmental Health Engineering and Management
Background: Because of natural and anthropogenic phenomena, most mountain areas experience significant soil loss. It is critical for watershed management to identify high soil loss rates and prone areas. Therefore, the present research aimed to estimate spatial annual soil loss rates and prioritize soil erosion prone areas of the Finca’aa watershed at sub-watershed level. Methods: The revised universal soil loss equation (RUSLE) model, the extension of geographic information system based on five parameters: rainfall erosivity (R), soil erodibility (K), slope length and slope steepness (LS), vegetation cover (C), and conservation techniques (P), was applied. This study also used weather data, a soil type map, a digital elevation model (DEM), and land use land cover, which were all analyzed using ArcGIS 10.4. Results: Annual soil loss rates ranged from negligible to 234 t ha-1 yr-1. The average rates of soil loss was 33.3 t ha-1 yr-1. Approximately 63.36% of the catchment was within and 36.64% of the catchment was above the maximum permissible level, respectively. Approximately 1.96% were in critical condition. Agricultural practices were the primary cause in the watershed’s mountain and hilly areas. Conclusion: The outcome is critical for planners and resource managers interested in long-term watershed management. Also, it is very important for sustainable growth development of 2030 agendas.
1 January 2022 in International Journal of Chemical Engineering
Ozonation is one of the most effective and efficient advanced oxidation processes (AOPs) and has shown great potential in the treatment of industrial effluent and wastewater. In the present work, the ozone‐Fenton process for % COD and color removal together with electrical energy per order (EE/O) determination for distillery industrial wastewater (DIW) was established. The process was developed by combining the ozone (O 3 ) with the Fenton (Fe 2+ /H 2 O 2 ) process. The ozone‐Fenton (O 3 /Fe 2+ /H 2 O 2 ) was compared with other treatment processes such as O 3 , Fe 2+ , H 2 O 2 , O 3 /Fe 2+ , O 3 /H 2 O 2 , and Fe 2+ /H 2 O 2 for EE/O together with % COD and color removal efficiency for DIW. The removal of color at 100% and chemical oxygen demand (COD) of 96.875% were achieved with a minimum of EE/O of 0.5315 kWh/m 3 using the O 3 /Fe 2+ /H 2 O 2 process by operating at optimum conditions. The % COD and color values obtained using O 3 /Fe 2+ /H 2 O 2 were significantly higher than those obtained using O 3 , Fe 2+ , H 2 O 2 , O 3 /Fe 2+ , O 3 /H 2 O 2 , and Fe 2+ /H 2 O 2 processes. The % color, % COD removal, and its associated EE/O were evaluated by varying Fe 2+ , H 2 O 2 , O 3 inlet and COD concentration, and initial wastewater pH using the O 3 /Fe 2+ /H 2 O 2 process. The synergy effect of the O 3 and Fe 2+ /H 2 O 2 processes was evaluated and reported. Our experimental findings suggest that combining O 3 with the Fe 2+ /H 2 O 2 process could effectively treat industrial effluent and wastewater.