Shi Junru

Ms. Shi Junru


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HZHui Zhang
Hui Zhang
JRJun Ruan
Jun Ruan
DLdandan liu
dandan liu
FYFan Yang
Fan Yang
SFSichen Fan
Sichen Fan
SZShougang Zhang
Shougang Zhang
An atomic clock with excellent long-term stability is important for maintaining the Local Atomic Time (TA(k)). The 87 Rb atomic fountain clock has the potential to fulfill these characteristics. It is required to operate continuously, similar to commercial cesium beam clocks and hydrogen masers. This paper describes the design and preliminary operation results of an 87 Rb atomic fountain continuous clock ( 87 RFCC) developed at the National Time Service Center (NTSC) of the Chinese Academy of Sciences. We adopted some improved design aspects and suppressed Majorana effect and microwave leakage to enhance the clock’s stability. Its continuous operation has been improved owing to the advantages of the high-reliability optical system and servo high-resolution offset generator (HROG) algorithm. We presented an algorithm for the 5 MHz/1 PPS signal output of the 87 RFCC through the HROG. The 87 RFCC exhibited a frequency stability of 1.91×10 -13 τ -1/2 , reaching 4.7×10 -16 at 200000 s. We referenced the 1 PPS output signal to the UTC(NTSC) and obtained the relative phase fluctuation of the 87 RFCC, which was within ±1.75 ns for approximately 90 days. We estimated the preliminary drift of the 87 RFCC relative to the UTC(NTSC) for three different periods at 0.000019±0.00148 ns/d/d, 0.00119±0.00182 ns/d/d, and -0.00155±0.00060 ns/d/d and discussed the results. During the 90-day evaluation period, although the frequency of the 87 RFCC relative to the UTC(NTSC) had changed, it still exhibited a low drift compared to cesium beam clocks and hydrogen masers, which highlights its potential for excellent long-term stability. The 87 RFCC investigated here has the potential to improve the local time scale.

5 January 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
FYFan Yang
Fan Yang
XWXinliang Wang
Xinliang Wang
JRJun Ruan
Jun Ruan
SJShi Junru
Shi Junru
SFSichen Fan
Sichen Fan
SZShougang Zhang
Shougang Zhang
The cesium atomic fountain clock is the world’s most accurate microwave atomic clock. The uncertainty of blackbody radiation (BBR) shift accounts for an increasingly large percentage of the uncertainty associated with fountain clocks and has become a key factor in the performance of fountain clocks. The uncertainty of BBR shift can be reduced by improving the system environment temperature. This study examined the mechanism by which the BBR shift of the transition frequency between the two hyperfine energy levels of the 133Cs ground state is generated and the calculation method for the BBR shift in the atomic fountain. Methods used to reduce the uncertainty of BBR shift were also examined. A fountain system structure with uniform temperature and good heat preservation was designed, and related technologies, such as that for measuring the temperature of the cesium fountain system, were studied. The results of 20 days of measurements, in combination with computer simulation results, showed that the temperature uncertainty of the atomic action zone is 0.12 °C and that the resulting uncertainty of BBR shift is 2.4 × 10−17.

13 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
YBYang Bai
Yang Bai
XWXinliang Wang
Xinliang Wang
SJShi Junru
Shi Junru
FYFan Yang
Fan Yang
JRJun Ruan
Jun Ruan
SZShougang Zhang
Shougang Zhang
Second-order Zeeman frequency shift is one of the major systematic factors affecting the frequency uncertainty performance of cesium atomic fountain clock. Second-order Zeeman frequency shift is calculated by experimentally measuring the central frequency of the (1,1) or (−1,−1) magnetically sensitive Ramsey transition. The low-frequency transition method can be used to measure the magnetic field strength and to predict the central fringe of (1,1) or (−1,−1) magnetically sensitive Ramsey transition. In this paper, we deduce the formula for magnetic field measurement using the low-frequency transition method and measured the magnetic field distribution of 4 cm inside the Ramsey cavity and 32 cm along the flight region experimentally. The result shows that the magnetic field fluctuation is less than 1 nT. The influence of low-frequency pulse signal duration on the accuracy of magnetic field measurement is studied and the optimal low-frequency pulse signal duration is determined. The central fringe of (−1,−1) magnetically sensitive Ramsey transition can be predicted by using a numerical integrating of the magnetic field “map”. Comparing the predicted central fringe with that identified by Ramsey method, the frequency difference between these two is, at most, a fringe width of 0.3. We apply the experimentally measured central frequency of the (−1,−1) Ramsey transition to the Breit-Rabi formula, and the second-order Zeeman frequency shift is calculated as 131.03 × 10−15, with the uncertainty of 0.10 × 10−15.