An atomic clock with excellent long-term stability is important for maintaining the Local Atomic Time (TA(k)). The 87 Rb atomic fountain clock has the potential to fulfill these characteristics. It is required to operate continuously, similar to commercial cesium beam clocks and hydrogen masers. This paper describes the design and preliminary operation results of an 87 Rb atomic fountain continuous clock ( 87 RFCC) developed at the National Time Service Center (NTSC) of the Chinese Academy of Sciences. We adopted some improved design aspects and suppressed Majorana effect and microwave leakage to enhance the clock’s stability. Its continuous operation has been improved owing to the advantages of the high-reliability optical system and servo high-resolution offset generator (HROG) algorithm. We presented an algorithm for the 5 MHz/1 PPS signal output of the 87 RFCC through the HROG. The 87 RFCC exhibited a frequency stability of 1.91×10 -13 τ -1/2 , reaching 4.7×10 -16 at 200000 s. We referenced the 1 PPS output signal to the UTC(NTSC) and obtained the relative phase fluctuation of the 87 RFCC, which was within ±1.75 ns for approximately 90 days. We estimated the preliminary drift of the 87 RFCC relative to the UTC(NTSC) for three different periods at 0.000019±0.00148 ns/d/d, 0.00119±0.00182 ns/d/d, and -0.00155±0.00060 ns/d/d and discussed the results. During the 90-day evaluation period, although the frequency of the 87 RFCC relative to the UTC(NTSC) had changed, it still exhibited a low drift compared to cesium beam clocks and hydrogen masers, which highlights its potential for excellent long-term stability. The 87 RFCC investigated here has the potential to improve the local time scale.
The modulation transfer spectroscopy (MTS) technique used to stabilize two different transition lines of rubidium, required for laser cooling of atoms, is investigated. The laser source is based on a 1560 nm semiconductor laser diode that is amplified by an erbium doped fiber amplifier (EDFA). The laser output is frequency doubled with a fiber coupled periodically poled Lithium Niobate (PPLN) crystal to 780 nm. To address the weak spectral features of repumping laser, a theoretical study is conducted followed by experimental verification. The 87Rb D2 line F = 1 → F' = 0 transition temperature-enhanced MTS signal is observed, which provides a choice to stabilize the repumping laser frquency on the F = 1 → F ' = 2 transition using frequency shifting with acousto-optic modulators (AOMs). Compared with the orignal MTS signal, this method is shown to be more stable and accurate for laser frequency locking. Laer frequency locking is realized by controlling the driving current of the seed laser using digital PID feedback. After locking, the laser linewidth is 35.36 kHz.
The pulsed optically pumped (POP) atomic clock has demonstrated unexpected performance in terms of frequency stability and drift. However, it remains a huge challenge to make this type of atomic clock more compact. Herein, we report the design of a miniaturized physics package, which is equipped with a magnetron microwave cavity holding a vapor cell of 1.3 cm internal diameter. The Zeeman transition spectrum reveals that the microwave cavity resonates in TE011-like mode. Based on a low-noise testbed, we also quantitatively analyze the relaxation time, linewidth, and noise sources of the resulting POP atomic clock. The population and coherence relaxation time are measured to be 3.16(0.16) and 2.97(0.03) ms under the temperature of 333 K, which are compatible well with the theoretical calculation. The Ramsey signal shows a contrast of 35% and a linewidth of 192 Hz. The total volume of the physics package is about 44 cm3, including a layer of magnetic shielding. The short-term frequency stability is measured to be 4.8 × 10−13τ−1/2 (where τ is the averaging time), which is mainly limited by the relative intensity noise of the laser system.
The cesium atomic fountain clock is the world’s most accurate microwave atomic clock. The uncertainty of blackbody radiation (BBR) shift accounts for an increasingly large percentage of the uncertainty associated with fountain clocks and has become a key factor in the performance of fountain clocks. The uncertainty of BBR shift can be reduced by improving the system environment temperature. This study examined the mechanism by which the BBR shift of the transition frequency between the two hyperfine energy levels of the 133Cs ground state is generated and the calculation method for the BBR shift in the atomic fountain. Methods used to reduce the uncertainty of BBR shift were also examined. A fountain system structure with uniform temperature and good heat preservation was designed, and related technologies, such as that for measuring the temperature of the cesium fountain system, were studied. The results of 20 days of measurements, in combination with computer simulation results, showed that the temperature uncertainty of the atomic action zone is 0.12 °C and that the resulting uncertainty of BBR shift is 2.4 × 10−17.
A cryogenic cesium atomic fountain clock is a novel clock with the microwave cavity and atomic free flight region placed in liquid nitrogen. On the one hand, the blackbody radiation shift is reduced at cryogenic temperature. On the other hand, the vacuum in the atomic free flight region is optimized, and the background gas collision shift reduced. The microwave resonant cavity is the most important unit in a cryogenic cesium atomic fountain clock. Through theoretical and simulative investigation, this study designs the configuration and dimensions for an optimized microwave cavity. Concurrently, experiments reveal the effects of temperature, pressure, humidity, and other factors on the resonant frequency of the microwave cavity. Combining the theoretical and experimental study, we obtain the resonant frequency difference between the microwave cavity in a cryogenic vacuum and at room temperature and ambient pressure. By subtracting this frequency difference, we adjust the microwave cavity for room temperature and ambient pressure, then vacuumize and immerse it in liquid nitrogen for verification and fine tuning. Finally, we determine that the microwave cavity resonant frequency deviation from the clock transition frequency is 10 kHz with an unloaded quality factor of 25 000, which meets the application requirements of the cryogenic cesium atomic fountain clock.
Microwave sources based on ultrastable lasers and optical frequency combs (OFCs) exhibit ultralow phase noise and ultrahigh-frequency stability, which are important for many applications. Herein, we present a microwave source that is phase-locked to an ultrastable continuous-wave laser, with a relative frequency instability of 7 × at 1 s. An Er:fiber-based OFC and an optic-to-electronic converter with low residual noise are employed to confer optical frequency stability on the 9.6 GHz microwave signal. Instead of using the normal cascaded Mach–Zehnder interferometer method, we developed a microwave regeneration method for converting optical pulses into microwave signals to further suppress the additional noise in the optic-to-electronic conversion process. The microwave regeneration method employs an optical-to-microwave phase detector based on a fiber-based Sagnac loop to produce the error signal between a 9.6 GHz dielectric resonator oscillator (DRO) and the OFC. The 9.6 GHz microwave (48th harmonic of the comb’s repetition rate) signal with the frequency stability of the ultrastable laser was achieved using a DRO that was phase-locked to the optical comb. Preliminary evaluations showed that the frequency instability of the frequency synthesizer from the optical to the 9.6 GHz microwave signal was approximately 2 × at 1 s, the phase noise was dBc Hz−1 at 1 Hz, and the timing noise was approximately 9 as Hz−1/2 (phase noise approx. dBc Hz−1). The 9.6 GHz signal from the photonic microwave source exhibited a short-term relative frequency instability of 2.1 × at 1 s, which is 1.5 times better than the previous results.