Harry Davies

Mr. Harry Davies


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2023 in Physiological Measurement
Verified
Journal Article
Open access
Peter CharltonPeter Charlton
Peter Charlton
John AllenJohn Allen
John Allen
Raquel BailónRaquel Bailón
Raquel Bailón
SBStephanie Baker
Stephanie Baker
JBJoachim A Behar
Joachim A Behar
TZTingting Zhu
Tingting Zhu
Photoplethysmography is a key sensing technology which is used in wearable devices such as smartwatches and fitness trackers. Currently, photoplethysmography sensors are used to monitor physiological parameters including heart rate and heart rhythm, and to track activities like sleep and exercise. Yet, wearable photoplethysmography has potential to provide much more information on health and wellbeing, which could inform clinical decision making. This Roadmap outlines directions for research and development to realise the full potential of wearable photoplethysmography. Experts discuss key topics within the areas of sensor design, signal processing, clinical applications, and research directions. Their perspectives provide valuable guidance to researchers developing wearable photoplethysmography technology.

28 August 2020 in Sensors
Verified
Journal Article
Open access
PDF file
HDHarry Davies
Harry Davies
IWIan Williams
Ian Williams
NPNicholas S. Peters
Nicholas S. Peters
DMDanilo Mandic
Danilo Mandic
The non-invasive estimation of blood oxygen saturation (SpO2) by pulse oximetry is of vital importance clinically, from the detection of sleep apnea to the recent ambulatory monitoring of hypoxemia in the delayed post-infective phase of COVID-19. In this proof of concept study, we set out to establish the feasibility of SpO2 measurement from the ear canal as a convenient site for long term monitoring, and perform a comprehensive comparison with the right index finger—the conventional clinical measurement site. During resting blood oxygen saturation estimation, we found a root mean square difference of 1.47% between the two measurement sites, with a mean difference of 0.23% higher SpO2 in the right ear canal. Using breath holds, we observe the known phenomena of time delay between central circulation and peripheral circulation with a mean delay between the ear and finger of 12.4 s across all subjects. Furthermore, we document the lower photoplethysmogram amplitude from the ear canal and suggest ways to mitigate this issue. In conjunction with the well-known robustness to temperature induced vasoconstriction, this makes conclusive evidence for in-ear SpO2 monitoring being both convenient and superior to conventional finger measurement for continuous non-intrusive monitoring in both clinical and everyday-life settings.

25 January 2022 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
HDHarry Davies
Harry Davies
PBPatrik Bachtiger
Patrik Bachtiger
IWIan Williams
Ian Williams
PMPhilip L. Molyneaux
Philip L. Molyneaux
NPNicholas S. Peters
Nicholas S. Peters
DMDanilo Mandic
Danilo Mandic
An ability to extract detailed spirometry-like breathing waveforms from wearable sensors promises to greatly improve respiratory health monitoring. Photoplethysmography (PPG) has been researched in depth for estimation of respiration rate, given that it varies with respiration through overall intensity, pulse amplitude and pulse interval. We compare and contrast the extraction of these three respiratory modes from both the ear canal and finger and show a marked improvement in the respiratory power for respiration induced intensity variations and pulse amplitude variations when recording from the ear canal. We next employ a data driven multi-scale method, noise assisted multivariate empirical mode decomposition (NA-MEMD), which allows for simultaneous analysis of all three respiratory modes to extract detailed respiratory waveforms from in-ear PPG. For rigour, we considered in-ear PPG recordings from healthy subjects, both older and young, patients with chronic obstructive pulmonary disease (COPD) and idiopathic pulmonary fibrosis (IPF) and healthy subjects with artificially obstructed breathing. Specific in-ear PPG waveform changes are observed for COPD, such as a decreased inspiratory duty cycle and an increased inspiratory magnitude, when compared with expiratory magnitude. These differences are used to classify COPD from healthy and IPF waveforms with a sensitivity of 87% and an overall accuracy of 92%. Our findings indicate the promise of in-ear PPG for COPD screening and unobtrusive respiratory monitoring in ambulatory scenarios and in consumer wearables.

29 January 2024 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
HDHarry Davies
Harry Davies
GHGhena Hammour
Ghena Hammour
MŻMarek Żyliński
Marek Żyliński
ANAmir Nassibi
Amir Nassibi
LSLjubisa Stankovic
Ljubisa Stankovic
DMDanilo Mandic
Danilo Mandic
The Ear-ECG provides a continuous Lead I like electrocardiogram (ECG) by measuring the potential difference related to heart activity by electrodes which are embedded within earphones. However, the significant increase in wearability and comfort enabled by Ear-ECG is often accompanied by a degradation in signal quality - an obstacle that is shared by the majority of wearable technologies. We aim to resolve this issue by introducing a Deep Matched Filter (Deep-MF) for the highly accurate detection of R-peaks in wearable ECG, thus enhancing the utility of Ear-ECG in real-world scenarios. The Deep-MF consists of an encoder stage, partially initialised with an ECG template, and an R-peak classifier stage. Through its operation as a Matched Filter, the encoder searches for matches with an ECG template in the input signal, prior to filtering these matches with the subsequent convolutional layers and selecting peaks corresponding to the ground-truth ECG. The latent representation of R-peak information is then fed into a R-peak classifier, of which the output provides precise R-peak locations. The proposed Deep Matched Filter is evaluated using leave-one-subject-out cross-validation over 36 subjects with an age range of 18-75, with the Deep-MF outperforming existing algorithms for R-peak detection in noisy ECG. The Deep-MF achieves a median R-peak recall of 94.9% and a median precision of 91.2% across subjects when evaluated with leave-one-subject-out cross validation. Overall, this Deep-Match framework serves as a valuable step forward for the real-world functionality of Ear-ECG and, through its interpretable operation, the acceptance of deep learning models in e-Health.

5 August 2022 in IEEE Transactions on Cognitive and Developmental Systems
Verified
Journal Article
Closed access
HDHarry Davies
Harry Davies
IWIan Williams
Ian Williams
GHGhena Hammour
Ghena Hammour
MYMetin Yarici
Metin Yarici
MSMichael J. Stacey
Michael J. Stacey
DMDanilo Mandic
Danilo Mandic
The brain is the most metabolically active organ in the body, which increases its metabolic activity, and thus oxygen consumption, with increasing cognitive demand. This motivates us to question whether increased cognitive workload may be measurable through changes in blood oxygen saturation. To this end, we explore the feasibility of cognitive workload tracking based on in-ear SpO2 measurements, which are known to be both robust and exhibit minimal delay. We consider cognitive workload assessment based on an N-back task with randomised order. It is shown that the 2-back and 3-back tasks (high cognitive workload) yield either the lowest median absolute SpO2 or largest median decrease in SpO2 in all of the subjects, indicating a measurable and statistically significant decrease in blood oxygen in response to increased cognitive workload. This makes it possible to classify the four N-back task categories, over 5 second epochs, with a mean accuracy of 90.6%, using features derived from in-ear pulse oximetry, including SpO2, pulse rate and respiration rate. These findings suggest that in-ear SpO2 measurements provide sufficient information for the reliable classification of cognitive workload over short time windows, which promises a new avenue for real time cognitive workload tracking.

15 May 2023 in Biomedical Signal Processing and Control
Verified
Journal Article
Open access
HDHarry Davies
Harry Davies
DMDanilo P. Mandic
Danilo P. Mandic