Konstantin Suslov

Prof. Dr. Konstantin Suslov

Department of Power Supply and Electrical Engineering, Irkutsk National Research Technical University, 664074 Irkutsk, Russia
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 September 2022 in Energies
Verified
Journal Article
Open access
PDF file
NSNataliia Shamarova
Nataliia Shamarova
Konstantin SuslovKonstantin Suslov
Konstantin Suslov
Pavel Vladimirovich IlyushinPavel Vladimirovich Ilyushin
Pavel Vladimirovich Ilyushin
ISIlya Shushpanov
Ilya Shushpanov
The modeling of battery energy storage systems (BESS) remains poorly researched, especially in the case of taking into account the power loss due to degradation that occurs during operation in the power system with a large penetration of generation from renewables and stochastic load from electric vehicles (EV). Meanwhile, the lifetime varies considerably from the manufacturer’s claim due to different operating conditions, and also depends on the level of renewable energy sources (RES) penetration, cyclic operation, temperature, discharge/charge rate, and depth of discharge. Choosing a simplistic approach to the degradation model can lead to unreliable conclusions in choosing the best management strategy and significant investment and operating costs. Most existing BESS models in stationary applications either assume zero degradation costs for storage or simplify battery life to a linear function of depth of discharge (DOD), which can lead to additional error in estimating the cost of BESS degradation. The complexity of constructing a lifetime model of BESS is due to the presence of nonlinear degradation of BESS at the beginning and at the end of the lifetime, as well as the difficulty in obtaining a large amount of experimental data that are close to the real-world operating conditions for the construction of most models. This article analyzes the features of BESS that are specific to their operation in microgrids in terms of the influence of the main stress factors on the degree of BESS degradation. This study also provides a review of existing models for assessing battery degradation.

1 August 2020 in Renewable Energy
Verified
Journal Article
Closed access
PSP. Sokolnikova
P. Sokolnikova
Pio Alessandro LombardiPio Alessandro Lombardi
Pio Alessandro Lombardi
BAB. Arendarski
B. Arendarski
Konstantin SuslovKonstantin Suslov
Konstantin Suslov
Antonio PantaleoAntonio Pantaleo
Antonio Pantaleo
PKP. Komarnicki
P. Komarnicki

1 May 2016 in Renewable Energy
Verified
Journal Article
Closed access
Pio Alessandro LombardiPio Alessandro Lombardi
Pio Alessandro Lombardi
TST. Sokolnikova
T. Sokolnikova
Konstantin SuslovKonstantin Suslov
Konstantin Suslov
NVN. Voropai
N. Voropai
Zbigniew A. StyczynskiZbigniew A. Styczynski
Zbigniew A. Styczynski

13 August 2022 in Energies
Verified
Journal Article
Open access
PDF file
DKDmitriy Karamov
Dmitriy Karamov
Pavel Vladimirovich IlyushinPavel Vladimirovich Ilyushin
Pavel Vladimirovich Ilyushin
Konstantin SuslovKonstantin Suslov
Konstantin Suslov
The current stage of development of autonomous energy systems is characterized by a rapid increase in renewable energy sources’ installed capacity. Such growth is observed both in centralized and isolated energy systems. Renewable energy sources show high efficiency in the electrification of rural remote settlements around the world. The power of such power complexes varies from several kilowatts to tens of megawatts. When solving the problems of rural remote settlements electrification, the main issues of optimizing the composition of equipment and the structure of the energy systems play an extremely important role. Moreover, depending on the specifications of the problem being solved, criteria for evaluating efficiency are used, which are different. For example, the following are used as objective functions: minimization of the levelized cost of energy and fossil fuel consumption; maximizing the standard of people living and reliability indicators; the payback period of the project and other indicators. Various combinations of objective functions and the solution to the multi-criteria optimization problem are possible. Moreover, an important stage in the development of renewable energy in remote rural areas is the availability of new mechanisms to support an environmentally friendly generation. These mechanisms can be used in solving problems of optimizing the structure and composition of energy equipment in remote power systems. The main purpose of this article is to demonstrate the world practices of optimal design of isolated energy systems. The review includes both the main questions that arise when solving such problems, and specific problems that require a more detailed analysis of the object of study.

31 March 2023 in Energies
Verified
Journal Article
Open access
PDF file
Pavel Vladimirovich IlyushinPavel Vladimirovich Ilyushin
Pavel Vladimirovich Ilyushin
Владислав ВольныйВладислав Вольный
Владислав Вольный
Konstantin SuslovKonstantin Suslov
Konstantin Suslov
SFSergey P. Filippov
Sergey P. Filippov
The development of AC distribution systems provides for the seamless integration of low-voltage microgrids with distributed energy resources (DERs). This poses new challenges for the control of normal, emergency, and post-emergency states of microgrids, calling for the creation and development of information and communications technology infrastructure. Power converters/inverters that are used to integrate renewable DERs lack inertia. Along with them, fossil fuel-fired generation units are also being integrated into microgrids. These include gas generator sets, diesel generator sets, and microturbines, having small (up to 1–2 s) values of mechanical inertia constants—Tj. This leads to an increase in the rate of transients by a factor of 5–10. Under these conditions, the technical requirements for the speed of automatic power flow control systems, as well as the methods they rely on, have to be reconsidered. Microgrids include DC microgrids, AC microgrids, and hybrid (AC-DC) microgrids. In the case of hybrid microgrids, DERs are connected to the DC grid and are integrated into the AC grid through a common inverter. The complexity of the task of microgrid control is due to the need to choose properly the type and extent of control actions so as to prevent the emergence and development of accidents. The employed control methods must ensure the reliable power supply to consumers and the quality of power in microgrids, as well as the reliable operation of the external distribution systems into which they are integrated. The article gives an overview of control methods for low-voltage AC and AC-DC microgrids, which allow one to tackle effectively solve the tasks.

22 August 2021 in Energies
Verified
Journal Article
Open access
PDF file
ARAndrey Rylov
Andrey Rylov
Pavel Vladimirovich IlyushinPavel Vladimirovich Ilyushin
Pavel Vladimirovich Ilyushin
AKAleksandr Leonidovich Kulikov
Aleksandr Leonidovich Kulikov
Konstantin SuslovKonstantin Suslov
Konstantin Suslov
The energy transition is accompanied by developing a digital decentralized low-carbon energy infrastructure with renewable-based generating plants as its main elements. In 2020, 15 photovoltaic power plants (PVPs) with an installed capacity of 364 MW were commissioned in Russia, which is 21.08% of the total installed PVP capacity of Russia. The findings of an analysis of Russia’s current regulatory and technical documents (RTD) concerning the frequency and active power flow control are presented. They indicate that all PVPs must participate in the general primary frequency control (GPFC). This requirement is due to large frequency deviations of transient processes resulting from an emergency active power shortage, which can shut down frequency-maintaining generating plants by relay or process protection devices and industrial consumers with significant damage to them. The requirements suggest full-scale tests of PVP to confirm their readiness for participation in GPFC. The program and results of checking the algorithm of change in the PVP active power, depending on frequency, are demonstrated with an example of one PVP. The full-scale tests confirmed the compliance of the certified PVP with this requirement. The plans for involving PVPs in the power flow control under various topology and operation conditions are considered.