Hasyma Abu HassN

Dr. Hasyma Abu HassN

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2020 in Diagnostics
Verified
Journal Article
Open access
PDF file
NMNOR AZURA MUHAMMAD
NOR AZURA MUHAMMAD
Muhammad Khalis Abdul KarimMuhammad Khalis Abdul Karim
Muhammad Khalis Abdul Karim
HHHasyma Abu HassN
Hasyma Abu HassN
MKMazliana Ahmad Kamarudin
Mazliana Ahmad Kamarudin
JWJeannie Hsiu Ding Wong
Jeannie Hsiu Ding Wong
KNKwan Hoong Ng
Kwan Hoong Ng
Pediatrics are more vulnerable to radiation and are prone to dose compared to adults, requiring more attention to computed tomography (CT) optimization. Hence, diagnostic reference levels (DRLs) have been implemented as part of optimization process in order to monitor CT dose and diagnostic quality. The noise index has recently been endorsed to be included as a part of CT optimization in the DRLs report. In this study, we have therefore set local DRLs for pediatric CT examination with a noise index as an indicator of image quality. One thousand one hundred and ninety-two (1192) paediatric patients undergoing CT brain, CT thorax and CT chest-abdomen-pelvis (CAP) examinations were analyzed retrospectively and categorized into four age groups; group 1 (0–1 year), group 2 (1–5 years), group 3 (5–10 years) and group 4 (10–15 years). For each group, data such as the volume-weighted CT dose index (CTDIvol), dose-length product (DLP) and the effective dose (E) were calculated and DRLs for each age group set at 50th percentile were determined. Both CT dose and image noise values between age groups have differed significantly with p-value < 0.05. The highest CTDIvol and DLP values in all age groups with the lowest noise index value reported in the 10–15 age group were found in CT brain examination. In conclusion, there was a significant variation in doses and noise intensity among children of different ages, and the need to change specific parameters to fit the clinical requirement.

25 February 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
NMNOR AZURA MUHAMMAD
NOR AZURA MUHAMMAD
ZKZunaide Kayun
Zunaide Kayun
HHHasyma Abu HassN
Hasyma Abu HassN
JWJeannie Hsiu Ding Wong
Jeannie Hsiu Ding Wong
KNKwan Hoong Ng
Kwan Hoong Ng
Muhammad Khalis Abdul KarimMuhammad Khalis Abdul Karim
Muhammad Khalis Abdul Karim
The aim of this study is to investigate the impact of CT acquisition parameter setting on organ dose and its influence on image quality metrics in pediatric phantom during CT examination. The study was performed on 64-slice multidetector CT scanner (MDCT) Siemens Definition AS (Siemens Sector Healthcare, Forchheim, Germany) using various CT CAP protocols (P1–P9). Tube potential for P1, P2, and P3 protocols were fixed at 100 kVp while P4, P5, and P6 were fixed at 80 kVp with used of various reference noise values. P7, P8, and P9 were the modification of P1 with changes on slice collimation, pitch factor, and tube current modulation (TCM), respectively. TLD-100 chips were inserted into the phantom slab number 7, 9, 10, 12, 13, and 14 to represent thyroid, lung, liver, stomach, gonads, and skin, respectively. The image quality metrics, signal to noise ratio (SNR) and contrast to noise ratio (CNR) values were obtained from the CT console. As a result, this study indicates a potential reduction in the absorbed dose up to 20% to 50% along with reducing tube voltage, tube current, and increasing the slice collimation. There is no significant difference (p > 0.05) observed between the protocols and image metrics.

19 February 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
SISHAHAD ABDUL WAHHAB IBRAHEEM
SHAHAD ABDUL WAHHAB IBRAHEEM
RMRozi Mahmud
Rozi Mahmud
SSSURAINI MOHAMAD SAINI
SURAINI MOHAMAD SAINI
HHHasyma Abu HassN
Hasyma Abu HassN
AKAysar Sabah K.
Aysar Sabah K.
ADAhmed M. Dirie
Ahmed M. Dirie
Objective: To compare the diagnostic performance of the automatic breast volume scanner (ABVS) against the handheld ultrasound (HHUS) in the differential diagnosis of benign and malignant breast lesions. Methods: A systematic search and review of studies involving ABVS and HHUS for breast cancer screening were performed. The search involved the data taken from Scopus, PubMed, and science direct databases and was conducted between the year 2011 to 2020. The prospective method was used in determining the inclusion and exclusion criteria while the evidence level was determined using the BI-RADS categories for diagnostic studies. In addition, the parameters of specificity, mean age, sensitivity, tumor number, and diagnostic accuracy of the ABVS and HHUS were summarized. Results: No systematic review or randomized controlled trial were identified in the systematic search while one cross-sectional study, eight retrospective studies, and 10 prospective studies were found. Sufficient follow-up of the subjects with benign and malignant findings were made only in 10 studies, in which only two had used ABVS and HHUS after performing mammographic screening and MRI. Analysis was made of 21 studies, which included 5448 lesions (4074 benign and 1374 malignant) taken from 6009 patients. The range of sensitivity was (0.72–1.0) for ABVS and (0.62–1.0) for HHUS; the specificity range was (0.52–0.98)% for ABVS and (0.49–0.99)% for HHUS. The accuracy range among the 11 studies was (80–99)% and (59–98)% for the HHUS and ABVS, respectively. The identified tumors had a mean size of 2.1 cm, and the detected cancers had a mean percentage of 94% (81–100)% in comparison to the non-cancer in all studies. Conclusions: The evidence available in the literature points to the fact that the diagnostic performance of both ABVS and HHUS are similar with reference to the differentiation of malignant and benign breast lesions.

13 October 2020 in Egyptian Journal of Radiology and Nuclear Medicine
Verified
Journal Article
Open access
PDF file
AAAbdullah Dhaifallah Almutairi
Abdullah Dhaifallah Almutairi
HHHasyma Abu HassN
Hasyma Abu HassN
SSSUBAPRIYA SUPPIAH
SUBAPRIYA SUPPIAH
OAOthman I Alomair
Othman I Alomair
AAAbdulbaset Alshoaibi
Abdulbaset Alshoaibi
RMRozi Mahmud
Rozi Mahmud
Magnetic resonance imaging (MRI) is one of the diagnostic imaging modalities employing in lesion detection in neurological disorders such as multiple sclerosis (MS). Advances in MRI techniques such as double inversion recovery (DIR) made it more sensitive to distinguish lesions in the brain. To investigate the lesion load on different anatomical regions of the brain with MS using DIR, fluid attenuated inversion recovery (FLAIR) and T2-weighted imaging (T2WI) sequences. A total of 97 MS patients were included in our retrospective study, confirmed by neurologist. The patients were randomly selected from the major hospital in Saudi Arabia. All images were obtained using 3T Scanner (Siemens Skyra). The images from the DIR, FLAIR, and T2WI sequence were compared on axial planes with identical anatomic position and the number of lesions was assigned to their anatomical region. Comparing the lesion load measurement at various brain anatomical regions showed a significant difference among those three methods (p < 0.05). DIR is a valuable MRI sequence for better delineation, greater contrast measurements and the increasing total number of MS lesions in MRI, compared with FLAIR, and T2WI and DIR revealed more intracortical lesions as well; therefore, in MS patients, it is recommended to add DIR sequence in daily routine imaging sequences.

6 December 2023 in Clinical and Experimental Pediatrics
Verified
Journal Article
Open access
PDF file
NANabila Hanem Arshad
Nabila Hanem Arshad
HHHasyma Abu HassN
Hasyma Abu HassN
This review aimed to assess the usefulness of various magnetic resonance imaging (MRI) techniques for the quantification of neonatal white matter myelination. The Scopus, PubMed, and Web of Science databases were searched to identify studies following the PRISMA (preferred reporting items for systematic reviews and meta-analyses) statement using quantitative MRI techniques to examine samples collected from neonates to quantify myelin. Twelve studies were ultimately included. The results demonstrated that in validation studies, relaxometry is the most frequently explored approach (83.33%), followed by magnetization transfer imaging (8.33%) and a new automatic segmentation technique (8.33%). Synthetic MRI is recommended for quantifying myelin in neonates because of several advantages that outweigh a few negligible limitations.

26 November 2024 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
CYChongshuang Yang
Chongshuang Yang
HHHasyma Abu HassN
Hasyma Abu HassN
NONur Farhayu Omar
Nur Farhayu Omar
TSTze Hui Soo
Tze Hui Soo
AYAhmad Shuib Bin Yahaya
Ahmad Shuib Bin Yahaya
JYJing Yang
Jing Yang