NOR AZURA MUHAMMAD

Mrs. NOR AZURA MUHAMMAD

Universiti Putra Malaysia (UPM)

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2020 in Diagnostics
Verified
Journal Article
Open access
PDF file
NMNOR AZURA MUHAMMAD
NOR AZURA MUHAMMAD
Muhammad Khalis Abdul KarimMuhammad Khalis Abdul Karim
Muhammad Khalis Abdul Karim
HHHasyma Abu HassN
Hasyma Abu HassN
MKMazliana Ahmad Kamarudin
Mazliana Ahmad Kamarudin
JWJeannie Hsiu Ding Wong
Jeannie Hsiu Ding Wong
KNKwan Hoong Ng
Kwan Hoong Ng
Pediatrics are more vulnerable to radiation and are prone to dose compared to adults, requiring more attention to computed tomography (CT) optimization. Hence, diagnostic reference levels (DRLs) have been implemented as part of optimization process in order to monitor CT dose and diagnostic quality. The noise index has recently been endorsed to be included as a part of CT optimization in the DRLs report. In this study, we have therefore set local DRLs for pediatric CT examination with a noise index as an indicator of image quality. One thousand one hundred and ninety-two (1192) paediatric patients undergoing CT brain, CT thorax and CT chest-abdomen-pelvis (CAP) examinations were analyzed retrospectively and categorized into four age groups; group 1 (0–1 year), group 2 (1–5 years), group 3 (5–10 years) and group 4 (10–15 years). For each group, data such as the volume-weighted CT dose index (CTDIvol), dose-length product (DLP) and the effective dose (E) were calculated and DRLs for each age group set at 50th percentile were determined. Both CT dose and image noise values between age groups have differed significantly with p-value < 0.05. The highest CTDIvol and DLP values in all age groups with the lowest noise index value reported in the 10–15 age group were found in CT brain examination. In conclusion, there was a significant variation in doses and noise intensity among children of different ages, and the need to change specific parameters to fit the clinical requirement.

25 February 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
NMNOR AZURA MUHAMMAD
NOR AZURA MUHAMMAD
ZKZunaide Kayun
Zunaide Kayun
HHHasyma Abu HassN
Hasyma Abu HassN
JWJeannie Hsiu Ding Wong
Jeannie Hsiu Ding Wong
KNKwan Hoong Ng
Kwan Hoong Ng
Muhammad Khalis Abdul KarimMuhammad Khalis Abdul Karim
Muhammad Khalis Abdul Karim
The aim of this study is to investigate the impact of CT acquisition parameter setting on organ dose and its influence on image quality metrics in pediatric phantom during CT examination. The study was performed on 64-slice multidetector CT scanner (MDCT) Siemens Definition AS (Siemens Sector Healthcare, Forchheim, Germany) using various CT CAP protocols (P1–P9). Tube potential for P1, P2, and P3 protocols were fixed at 100 kVp while P4, P5, and P6 were fixed at 80 kVp with used of various reference noise values. P7, P8, and P9 were the modification of P1 with changes on slice collimation, pitch factor, and tube current modulation (TCM), respectively. TLD-100 chips were inserted into the phantom slab number 7, 9, 10, 12, 13, and 14 to represent thyroid, lung, liver, stomach, gonads, and skin, respectively. The image quality metrics, signal to noise ratio (SNR) and contrast to noise ratio (CNR) values were obtained from the CT console. As a result, this study indicates a potential reduction in the absorbed dose up to 20% to 50% along with reducing tube voltage, tube current, and increasing the slice collimation. There is no significant difference (p > 0.05) observed between the protocols and image metrics.