The surgical treatment of peri-implantitis is currently based on the removal of biofilms from the implant surface by primary means of mechanical and physical treatments. However, such approaches often determine some alterations of the implant surface with detrimental effects on re-osseointegration. This study aims to evaluate the effects of four different mechanical and physical treatments on titanium samples with moderately rough surface. Air powder abrasion (AP) with glycine powder, a titanium brush (TB) and a diode laser at 3 W (L3) and 4 W (L4) were tested. Surface morphology, roughness and chemical composition were then assessed by scanning electron microscope (SEM), white light interferometer and X-ray photoelectron spectroscopy (XPS), respectively. The microscopic analysis revealed significant alterations in surface morphology on TB samples, while AP and L3 had only a minor or null impact. L4 samples revealed signs of overheating due to the excessive power. Nevertheless, the overall roughness of the samples was not significantly altered in terms of roughness parameters. Similarly, surface chemical composition was not significantly affected by the treatments. Among the treatments tested in this study, air powder abrasion with glycine powder and 3 W diode laser had the lowest impact on surface physicochemical properties.
The surface of metal parts operating at high temperature in energy production and aerospace industry is typically exposed to thermal stresses and oxidation phenomena. To this aim, plasma spraying was employed to deposit NiCoCrAlYRe coatings on metal substrates. The effects of early-stage oxidation, at ~1100 °C, on their microstructure were investigated. The partial infiltration of oxygen through some open pores and microcracks embedded in coating microstructure locally assistedthe formation of a stable Al2O3 scale at the splat boundary, while the diffusion of Cr and Ni and the following growth of Cr2O3, Ni(Cr,Al)2O4 and NiO were restricted to Al depleted isolated areas. At the same time, a continuous, dense and well adherent Al2O3 layer grew on the top-surface, and was somewhere supported by a thin mixed oxide scale mainly composed of Cr2O3 and spinels. Based on these results, the addition of Re to the NiCoCrAlY alloy is able to enhance the oxidation resistance.
The SORGENTINA-RF project aims at developing a 14 MeV fusion neutron source featuring an emission rate in the order of 5–7 × 10 s. The plant relies on a metallic water-cooled rotating target and a deuterium (50%) and tritium (50%) ion beam. Beyond the main focus of medical radioisotope production, the source may represent a multi-purpose neutron facility by implementing a series of neutron-based techniques. Among the different engineering and technological issues to be addressed, the production of incondensable gases and corrosion product into the rotating target deserves a dedicated investigation. In this study, a preliminary analysis is carried out, considering the general layout of the target and the present choice of the target material.
Catalytic aerobic oxidation of benzyl alcohol (BnOH) to benzaldehyde (PhCHO) over supported noble metal catalysts has grabbed the attention of researchers due to the critical role of PhCHO in numerous industrial syntheses. In the present study, a novel catalyst, Pd-P alloy supported on aminopropyl-functionalized mesoporous silica (NH2-SiO2), was prepared through in situ reduction and characterized by BET-BJH analysis, SEM, TEM, XRD, FTIR, TG-DTA, and XPS. Chemical properties and catalytic performance of Pd-P/NH2-SiO2 were compared with those of Pd° nanoparticles (NPs) deposited on the same support. Over Pd-P/NH2-SiO2, the BnOH conversion to PhCHO was much higher than over Pd°/NH2-SiO2, and significantly influenced by the nature of solvent, reaching 57% in toluene at 111 °C, with 63% selectivity. Using pure oxygen as an oxidant in the same conditions, the BnOH conversion increased up to 78%, with 66% selectivity. The role of phosphorous in improving the activity may consist of the strong interaction with Pd that favours metal dispersion and lowers Pd electron density.
Microstructural analysis by electron microscopy techniques is a powerful tool for determining the basic and functional properties of materials and their relationship with the processing parameters, thus giving useful keys to designers and producers for optimizing performance and durability of the related components. Materials and coatings produced by thermal spraying of powder-based raw materials exhibit unique physical, thermal and mechanical properties, resulting from the thermal effects associated to their processing. These properties can be tailored depending on the application the components are addressed to. Moreover, they can change during operation because of any aging mechanisms promoted by oxidation, corrosion, thermal exposure and wear, that can be responsible of reduced performance, degradation and damage, thus affecting their durability and service lifetime. In this work, the potentiality of scanning electron microscopy (SEM) is investigated with the purpose to analyze in detail the complex microstructure and some aging effects in metallic, ceramic and composite coatings, such as formation of oxide scales, grain growth, sintering, and so on. The analysis can be successfully expanded to a wide variety of materials as well as to the study of complex mechanisms of degradation occurring during service