Eladio Altamira Colado

Dr. Eladio Altamira Colado

Bioengineering and Environmental Health Department, Autonomous University of Baja California, Mexicali, Baja California, Mexico
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 April 2024 in Atmosphere
Verified
Journal Article
Open access
PDF file
Eladio Altamira ColadoEladio Altamira Colado
Eladio Altamira Colado
Daniel Cuevas-GonzálezDaniel Cuevas-González
Daniel Cuevas-González
MRMarco Antonio Reyna
Marco Antonio Reyna
Juan Pablo Garcia VazquezJuan Pablo Garcia Vazquez
Juan Pablo Garcia Vazquez
Roberto L. AvitiaRoberto L. Avitia
Roberto L. Avitia
AVAlvaro Osornio Vargas
Alvaro Osornio Vargas
Air pollution is caused by the presence of polluting elements. Ozone (O3), carbon monoxide (CO), carbon dioxide (CO2), nitrogen dioxide (NO2), sulfur dioxide (SO2), and particulate matter (PM) are the most controlled gasses because they can be released into the atmosphere naturally or as a result of human activity, which affects air quality and causes disease and premature death in exposed people. Depending on the substance being measured, ambient air monitors have different types of air quality sensors. In recent years, there has been a growing interest in designing drones as mobile sensors for monitoring air pollution. Therefore, the objective of this paper is to provide a comprehensive patent review to gain insight into the proprietary technologies currently used in drones used to monitor outdoor air pollution. Patent searches were conducted using three different patent search engines: Google Patents, WIPO’s Patentscope, and the United States Patent and Trademark Office (USPTO). The analysis of each patent consists of extracting data that supply information regarding the type of drone, sensor, or equipment for measuring PM, the lack or presence of a cyclone separator, and the ability to process the turbulence generated by the drone’s propellers. A total of 1473 patent documents were retrieved using the search engine. However, only 13 met the inclusion criteria, including patent documents reporting drone designs for outdoor air pollution monitoring. Therefore, was found that most patents fall under class G01N (measurement; testing) according to the International Patents Classification, where the most common sensors and devices are infrared or visible light cameras, cleaning devices, and GPS tracking devices. The most common tasks performed by drones are air pollution monitoring, assessment, and control. These categories cover different aspects of the air pollution management cycle and are essential to effectively address this environmental problem.

1 November 2021 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
Eladio Altamira ColadoEladio Altamira Colado
Eladio Altamira Colado
Miguel Bravo-ZanogueraMiguel Bravo-Zanoguera
Miguel Bravo-Zanoguera
Daniel Cuevas-GonzálezDaniel Cuevas-González
Daniel Cuevas-González
MRMarco Antonio Reyna
Marco Antonio Reyna
Roberto L. AvitiaRoberto L. Avitia
Roberto L. Avitia
The development of electrocardiogram (ECG) wearable devices has increased due to its applications on ambulatory patients. ECG signals provide useful information about the heart behavior, but when daily activities are monitored, motion artifacts are introduced producing saturation of the signal, thus losing the information. The typical resolution used to record ECG signals is of maximum 16-bit, which might not be enough to detect low-amplitude potentials and at the same time avoid saturation due to baseline wander, since this last issue demands a low-gain signal chain. A high-resolution provides a more detailed ECG signal under a low gain input, and if the signal is corrupted by motion artifact noise but is not saturated, it can be filtered to recover the signal of interest. In this work, a 24-bit ADC is used to record the ECG, and a new method, the rest ECG cycle template, is proposed to remove the baseline wander. This new method is compared to high-pass filter and spline interpolation methods in their ability to remove baseline wander. This new method presumes that a user is able to establish a rest ECG during his/her daily activities.

15 November 2023 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
MBMartin Aaron Sanchez Barajas
Martin Aaron Sanchez Barajas
Daniel Cuevas-GonzálezDaniel Cuevas-González
Daniel Cuevas-González
MRMarco Antonio Reyna
Marco Antonio Reyna
JDJuan C. Delgado-Torres
Juan C. Delgado-Torres
Eladio Altamira ColadoEladio Altamira Colado
Eladio Altamira Colado
Roberto L. AvitiaRoberto L. Avitia
Roberto L. Avitia
Air pollution is a critical public health problem that has increased during the past decades. High levels of air pollution have affected natural environments and people’s health, causing significant problems and, in severe cases, premature death. A growing trend called “Personal air monitoring” has become important for prevention of and reduction in exposure to air pollutants. The development of personal particulate matter sensors is still a topic of study among the scientific community. Some important identified challenges are improving the sample rate, precision, stability, dimensions and costs, making personal monitoring of air quality affordable. This work proposes the development of a low-cost particulate matter optical sensor to count the number of particles in real time using the Arduino platform and wireless transmission. Our results demonstrated that using a digital input of the microcontroller instead of the analog–digital converter, after conditioning the sensor signal, allows a very high max particle count, which can be compared to that of expensive sensors. In addition, particulate matter (PM) measurements were compared with a GP2Y1014AU0F dust sensor to validate the accuracy of the sensor.

12 October 2024 in Atmosphere
Verified
Journal Article
Open access
PDF file
Daniel Cuevas-GonzálezDaniel Cuevas-González
Daniel Cuevas-González
JDJuan C. Delgado-Torres
Juan C. Delgado-Torres
MRMarco Antonio Reyna
Marco Antonio Reyna
Eladio Altamira ColadoEladio Altamira Colado
Eladio Altamira Colado
Juan Pablo Garcia VazquezJuan Pablo Garcia Vazquez
Juan Pablo Garcia Vazquez
Roberto L. AvitiaRoberto L. Avitia
Roberto L. Avitia
Air pollution is recognized by the World Health Organization as the major environmental threat; therefore, air quality is constantly being monitored by monitoring stations. However, the most common atmospheric pollutants being monitored do not include pollen. Among the reasons for the lack of pollen control is that there are different types and sizes of pollen. The largest particles commonly being monitored by air monitoring stations have a maximum aerodynamic diameter of 10 microns, while the aerodynamic diameter of most pollen grains is known to range from 10 to 100 microns. For this reason, most pollen is not being detected by air monitoring stations. For the patents found in a literature review, monitoring pollen concentration in the air requires the discrimination of pollen grains from particulate matter of a similar size, as well as the identification of the type of pollen grains detected, since different pollen types may produce different effects, such as allergic reactions, asthma, and lung cancer, in exposed people. In this work, 15 patent documents regarding pollen monitoring were identified and reviewed using three search engines: Google Patents, WIPO’s PatentScope, and the United States Patent and Trademark Office (USPTO) database. The extracted data from the patents included whether they differentiate pollen type, pollen size, and sensor type and whether they provide real-time data. The results show that 93.33% of the patents identify pollen type, while 80% of the patents identify pollen size. Most of the patents use light-scattering and image sensors and use image processing techniques to analyze particles. Furthermore, 40% of the patents were found to implement artificial intelligence. Further, it was found that only nine patents provide real-time data, which is an important feature of an air monitoring system.

14 November 2020 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
Daniel Cuevas-GonzálezDaniel Cuevas-González
Daniel Cuevas-González
Miguel Bravo-ZanogueraMiguel Bravo-Zanoguera
Miguel Bravo-Zanoguera
Eladio Altamira ColadoEladio Altamira Colado
Eladio Altamira Colado
Roberto L. AvitiaRoberto L. Avitia
Roberto L. Avitia
Juan Pablo Garcia VazquezJuan Pablo Garcia Vazquez
Juan Pablo Garcia Vazquez
MRMarco Antonio Reyna
Marco Antonio Reyna
The development of portable ECG technology has found growing markets, from wearable ECG sensors to ambulatory ECG recorders, encountering challenges of moderately complex to tightly regulated devices. This study investigated how a typical 0.5–40 Hz bandwidth ECG is affected by motion artifact when using analog front-end (AFE) integrated circuits such as the AD823X family. It is known that the typical amplitude resolution of current mobile health ECG devices is 10–12 bits, and sometimes 16-bits, which is enough for monitoring but might be insufficient to identify the small potential amplitudes useful in diagnoses. The interest now is on the interplay of how a digital resolution choice and variable gain can cope with motion artifacts inherent in mobile health devices. With our methodology for a rapid prototyping of an ECG device, and using the AFE AD8232 and Bluetooth communication, a specific cardiac monitor ECG configuration was evaluated under two microcontroller systems of different resolution: a generic Arduino Nano board which featured a 10-bit analog-to-digital converter (ADC) and the 24-bit ADC of Silicon Labs C8051F350 board. The ECG cardiac monitor setup, recommended by Analog Devices, featuring two gain values under these two different microcontroller systems, was explored as to its ability to solve motion artifact problems.

21 September 2025 in Environments
Verified
Journal Article
Open access
PDF file
Daniel Cuevas-GonzálezDaniel Cuevas-González
Daniel Cuevas-González
MBMartin Aaron Sanchez Barajas
Martin Aaron Sanchez Barajas
MRMarco Antonio Reyna
Marco Antonio Reyna
Juan Pablo Garcia VazquezJuan Pablo Garcia Vazquez
Juan Pablo Garcia Vazquez
Eladio Altamira ColadoEladio Altamira Colado
Eladio Altamira Colado
Roberto L. AvitiaRoberto L. Avitia
Roberto L. Avitia
The health impact of air pollutants has generated a trend in the design and manufacture of portable, personal and fixed PM monitoring systems to help reduce exposure to air pollutants. However, these devices still need to be improved and properly evaluated to compete with environmental monitors in the market. In this work, a test chamber with controlled environmental conditions and wireless connectivity is developed for the evaluation of low-cost portable and personal PM sensors. The developed system ensures rapid evaluation tests ranging from seconds to hours to corroborate prolonged operation and correct calibration. The system is controlled by a Python-based graphical user interface (GUI) and monitors PM concentration, altitude, relative humidity, atmospheric pressure, illuminance, and temperature measurements. Fifty measurement tests with a duration of 10 min each were conducted to ensure robust performance and data transfer. Subsequently, four calibration tests were conducted using two SENSIRION SPS30 (SPS A and SPS B) personal PM sensors and two PMS5003 (PMS A and PMS B) personal PM sensors. The Prana Air PAS-OUT-01 sensor served as the reference to calculate the correlations and the descriptive statistics between each sensor to be calibrated. A contamination source was employed utilizing a monodispersed aerosol generator for 0.46 µm latex polystyrene particle atomization. Linear regression was applied during the calibration to determine the calibration coefficients, which were then used to adjust the sensor readings in the respective code and descriptive statistics of the sensor calibration tests were calculated. For the PMS5003 sensors, the Pearson correlation coefficients (r) after calibration were PMS A: 0.9870 and PMS B: 0.9898 compared to their uncalibrated values of PMS A: 0.9828 and PMS B: 0.9863. In contrast, the uncalibrated SPS A sensor initially had a correlation of 0.9939, which slightly decreased to 0.9917 after calibration. Meanwhile, the uncalibrated SPS B sensor showed a correlation of 0.9422, which improved to 0.9715 after calibration.