Alberto Arroyo

Dr. Alberto Arroyo

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 September 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Sergio BustamanteSergio Bustamante
Sergio Bustamante
Mario MananaMario Manana
Mario Manana
AAAlberto Arroyo
Alberto Arroyo
Pablo CastroPablo Castro
Pablo Castro
ALAlberto Laso
Alberto Laso
RMRaquel Martinez
Raquel Martinez
Power transformers are the most important assets of electric power substations. The reliability in the operation of electric power transmission and distribution is due to the correct operation and maintenance of power transformers. The parameters that are most used to assess the health status of power transformers are dissolved gas analysis (DGA), oil quality analysis (OQA) and content of furfuraldehydes (FFA) in oil. The parameter that currently allows for simple online monitoring in an energized transformer is the DGA. Although most of the DGA continues to be done in the laboratory, the trend is online DGA monitoring, since it allows for detection or diagnosis of the faults throughout the life of the power transformers. This study presents a review of the main DGA monitors, single- or multi-gas, their most important specifications, accuracy, repeatability and measurement range, the types of installation, valve or closed loop, and number of analogue inputs and outputs. This review shows the differences between the main existing DGA monitors and aims to help in the selection of the most suitable DGA monitoring approach according to the needs of each case.

2 December 2015 in Energies
Verified
Journal Article
Open access
PDF file
AAAlberto Arroyo
Alberto Arroyo
Pablo CastroPablo Castro
Pablo Castro
RMRaquel Martinez
Raquel Martinez
Mario MananaMario Manana
Mario Manana
AMAlfredo Madrazo
Alfredo Madrazo
AGAntonio Gonzalez
Antonio Gonzalez
This paper presents the steady and dynamic thermal balances of an overhead power line proposed by CIGRE (Technical Brochure 601, 2014) and IEEE (Std.738, 2012) standards. The estimated temperatures calculated by the standards are compared with the averaged conductor temperature obtained every 8 min during a year. The conductor is a LA 280 Hawk type, used in a 132-kV overhead line. The steady and dynamic state comparison shows that the number of cases with deviations to conductor temperatures higher than 5 ∘ C decreases from around 20% to 15% when the dynamic analysis is used. As some of the most critical variables are magnitude and direction of the wind speed, ambient temperature and solar radiation, their influence on the conductor temperature is studied. Both standards give similar results with slight differences due to the different way to calculate the solar radiation and convection. Considering the wind, both standards provide better results for the estimated conductor temperature as the wind speed increases and the angle with the line is closer to 90 ∘ . In addition, if the theoretical radiation is replaced by that measured with the pyranometer, the number of samples with deviations higher than 5 ∘ C is reduced from around 15% to 5%.

17 June 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
RMRaquel Martinez
Raquel Martinez
Pablo CastroPablo Castro
Pablo Castro
AAAlberto Arroyo
Alberto Arroyo
Mario MananaMario Manana
Mario Manana
NGnoemi galan
noemi galan
ALAlberto Laso
Alberto Laso
The complexity in the power system topology, together with the new paradigm in generation and demand, make achieving an adequate level of supply quality a complicated goal for distribution companies. The electrical system power quality is subject to different regulations. On one hand, EN-50160 establishes the characteristics of the voltage supplied by public electricity networks, therefore affecting distribution companies. On the other hand, the EN-61000 series of standards regulates the electromagnetic compatibility of devices connected to the network, therefore affecting the loads. Power companies and device manufacturers are both responsible and affected in the issue of quality of supply. Despite the regulations, there are certain aspects of the supply quality that are not solved. One of the most important is the location of the disturbance’s origin. This paper presents a review of the main techniques to locate the disturbance’s origin in the electric network through two approaches: identification of the disturbance’s cause and the location of the origin.

1 May 2019 in Electric Power Systems Research
Verified
Journal Article
Closed access
RMRaquel Martinez
Raquel Martinez
AUA. Useros
A. Useros
Pablo CastroPablo Castro
Pablo Castro
AAAlberto Arroyo
Alberto Arroyo
Mario MananaMario Manana
Mario Manana

13 December 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Sergio BustamanteSergio Bustamante
Sergio Bustamante
Mario MananaMario Manana
Mario Manana
AAAlberto Arroyo
Alberto Arroyo
ALAlberto Laso
Alberto Laso
RMRaquel Martinez
Raquel Martinez
Power transformers are considered to be the most important assets in power substations. Thus, their maintenance is important to ensure the reliability of the power transmission and distribution system. One of the most commonly used methods for managing the maintenance and establishing the health status of power transformers is dissolved gas analysis (DGA). The presence of acetylene in the DGA results may indicate arcing or high-temperature thermal faults in the transformer. In old transformers with an on-load tap-changer (OLTC), oil or gases can be filtered from the OLTC compartment to the transformer’s main tank. This paper presents a method for determining the transformer oil contamination from the OLTC gases in a group of power transformers for a distribution system operator (DSO) based on the application of the guides and the knowledge of experts. As a result, twenty-six out of the 175 transformers studied are defined as contaminated from the OLTC gases. In addition, this paper presents a methodology based on machine learning techniques that allows the system to determine the transformer oil contamination from the DGA results. The trained model achieves an accuracy of 99.76% in identifying oil contamination.

21 February 2021 in Energies
Verified
Journal Article
Open access
PDF file
RMRaquel Martinez
Raquel Martinez
Mario MananaMario Manana
Mario Manana
AAAlberto Arroyo
Alberto Arroyo
Sergio BustamanteSergio Bustamante
Sergio Bustamante
ALAlberto Laso
Alberto Laso
RMRafael Minguez
Rafael Minguez
Integration of a large number of renewable systems produces line congestions, resulting in a problem for distribution companies, since the lines are not capable of transporting all the energy that is generated. Both environmental and economic constraints do not allow the building new lines to manage the energy from renewable sources, so the efforts have to focus on the existing facilities. Dynamic Rating Management (DRM) of power lines is one of the best options to achieve an increase in the capacity of the lines. The practical application of DRM, based on standards IEEE (Std.738, 2012) and CIGRE TB601 (Technical Brochure 601, 2014) , allows to find several deficiencies related to errors in estimations. These errors encourage the design of a procedure to obtain high accuracy ampacity values. In the case of this paper, two methodologies have been tested to reduce estimation errors. Both methodologies use the variation of the weather inputs. It is demonstrated that a reduction of the conductor temperature calculation error has been achieved and, consequently, a reduction of ampacity error.