Power transformers are the most important assets of electric power substations. The reliability in the operation of electric power transmission and distribution is due to the correct operation and maintenance of power transformers. The parameters that are most used to assess the health status of power transformers are dissolved gas analysis (DGA), oil quality analysis (OQA) and content of furfuraldehydes (FFA) in oil. The parameter that currently allows for simple online monitoring in an energized transformer is the DGA. Although most of the DGA continues to be done in the laboratory, the trend is online DGA monitoring, since it allows for detection or diagnosis of the faults throughout the life of the power transformers. This study presents a review of the main DGA monitors, single- or multi-gas, their most important specifications, accuracy, repeatability and measurement range, the types of installation, valve or closed loop, and number of analogue inputs and outputs. This review shows the differences between the main existing DGA monitors and aims to help in the selection of the most suitable DGA monitoring approach according to the needs of each case.

2 December 2015 in Energies
Verified
Journal Article
Open access
PDF file
AAAlberto Arroyo
Alberto Arroyo
Pablo CastroPablo Castro
Pablo Castro
RMRaquel Martinez
Raquel Martinez
Mario MananaMario Manana
Mario Manana
AMAlfredo Madrazo
Alfredo Madrazo
AGAntonio Gonzalez
Antonio Gonzalez
This paper presents the steady and dynamic thermal balances of an overhead power line proposed by CIGRE (Technical Brochure 601, 2014) and IEEE (Std.738, 2012) standards. The estimated temperatures calculated by the standards are compared with the averaged conductor temperature obtained every 8 min during a year. The conductor is a LA 280 Hawk type, used in a 132-kV overhead line. The steady and dynamic state comparison shows that the number of cases with deviations to conductor temperatures higher than 5 ∘ C decreases from around 20% to 15% when the dynamic analysis is used. As some of the most critical variables are magnitude and direction of the wind speed, ambient temperature and solar radiation, their influence on the conductor temperature is studied. Both standards give similar results with slight differences due to the different way to calculate the solar radiation and convection. Considering the wind, both standards provide better results for the estimated conductor temperature as the wind speed increases and the angle with the line is closer to 90 ∘ . In addition, if the theoretical radiation is replaced by that measured with the pyranometer, the number of samples with deviations higher than 5 ∘ C is reduced from around 15% to 5%.

1 June 2019 in Applied Thermal Engineering
Verified
Journal Article
Closed access
Sergio BustamanteSergio Bustamante
Sergio Bustamante
RMR. Mínguez
R. Mínguez
AAA. Arroyo
A. Arroyo
Mario MananaMario Manana
Mario Manana
ALA. Laso
A. Laso
RMR. Martinez
R. Martinez

17 June 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
RMRaquel Martinez
Raquel Martinez
Pablo CastroPablo Castro
Pablo Castro
AAAlberto Arroyo
Alberto Arroyo
Mario MananaMario Manana
Mario Manana
NGnoemi galan
noemi galan
ALAlberto Laso
Alberto Laso
The complexity in the power system topology, together with the new paradigm in generation and demand, make achieving an adequate level of supply quality a complicated goal for distribution companies. The electrical system power quality is subject to different regulations. On one hand, EN-50160 establishes the characteristics of the voltage supplied by public electricity networks, therefore affecting distribution companies. On the other hand, the EN-61000 series of standards regulates the electromagnetic compatibility of devices connected to the network, therefore affecting the loads. Power companies and device manufacturers are both responsible and affected in the issue of quality of supply. Despite the regulations, there are certain aspects of the supply quality that are not solved. One of the most important is the location of the disturbance’s origin. This paper presents a review of the main techniques to locate the disturbance’s origin in the electric network through two approaches: identification of the disturbance’s cause and the location of the origin.

10 November 2015 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Open access
RAMON LECUNARAMON LECUNA
RAMON LECUNA
FDFernando Delgado
Fernando Delgado
COCristian Olmo
Cristian Olmo
Pablo CastroPablo Castro
Pablo Castro
Inmaculada FernandezInmaculada Fernandez
Inmaculada Fernandez
CRCarlos J Renedo
Carlos J Renedo
The transformers lifespan depends importantly on its refrigeration. Mineral oils perform this work in the majority of the power transformers. However, this type of coolant has two main drawbacks: low biodegradability and low ignition point. Several alternative liquids are being developed in order to overcome these drawbacks. This paper compares their thermal-fluid behavior with a mineral oil by means of several parameters, such as temperature, flow rate, fluids velocity, convective heat transfer coefficient (h) and the cooling criterion (P). These are calculated using the numerical results of the simulation of a 3D-model of a Low Voltage Winding that belongs to a power transformer with ONAN cooling. The software COMSOL Multiphysics has allowed the simulation of the geometry using a physical model in which buoyancies and viscous forces are the only considered establishing the natural convection. As a result of the comparison, it is clear that the mineral oil is the best coolant liquid. Among the alternative liquids, silicone oil would be the second best coolant fluid, followed by the synthetic and natural esters, respectively. On the other hand, it seems to be clear that the 3D simulations can be used to compare properly the cooling capacities of the liquids.

12 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Pablo CastroPablo Castro
Pablo Castro
RAMON LECUNARAMON LECUNA
RAMON LECUNA
Mario MananaMario Manana
Mario Manana
MMMaria Jose Martin
Maria Jose Martin
DCDolores del Campo
Dolores del Campo
Efficiency in power lines operation is becoming more crucial as the electrification increases and more renewable energies are connected into the grid. New methods and sensors are being added to create smart grids to face these challenges and conductor temperature sensors are one of them. Contact temperature sensors have several problems regarding safety and electronic damage due to the electromagnetic fields induced on the conductors. The goal of this paper is to describe an infrared temperature measurement sensor and to compare contact and non-contact temperature measurements to estimate the temperature of power lines. Measurements were done for almost a year, storing around 150,000 measures of contact and infrared thermometers for many different weather and load conditions. The results conclude that the infrared system can be successfully used to control the temperature of the overhead conductor within a range of less than 4 ∘C difference with respect to contact temperature methods for the 88% of the samples and less than 6 ∘C for the 99%.