Sergio Bustamante

Mr. Sergio Bustamante

Universidad de Cantabria
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 September 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Sergio BustamanteSergio Bustamante
Sergio Bustamante
Mario MananaMario Manana
Mario Manana
AAAlberto Arroyo
Alberto Arroyo
Pablo CastroPablo Castro
Pablo Castro
ALAlberto Laso
Alberto Laso
RMRaquel Martinez
Raquel Martinez
Power transformers are the most important assets of electric power substations. The reliability in the operation of electric power transmission and distribution is due to the correct operation and maintenance of power transformers. The parameters that are most used to assess the health status of power transformers are dissolved gas analysis (DGA), oil quality analysis (OQA) and content of furfuraldehydes (FFA) in oil. The parameter that currently allows for simple online monitoring in an energized transformer is the DGA. Although most of the DGA continues to be done in the laboratory, the trend is online DGA monitoring, since it allows for detection or diagnosis of the faults throughout the life of the power transformers. This study presents a review of the main DGA monitors, single- or multi-gas, their most important specifications, accuracy, repeatability and measurement range, the types of installation, valve or closed loop, and number of analogue inputs and outputs. This review shows the differences between the main existing DGA monitors and aims to help in the selection of the most suitable DGA monitoring approach according to the needs of each case.

1 June 2019 in Applied Thermal Engineering
Verified
Journal Article
Closed access
Sergio BustamanteSergio Bustamante
Sergio Bustamante
RMR. Mínguez
R. Mínguez
AAA. Arroyo
A. Arroyo
Mario MananaMario Manana
Mario Manana
ALA. Laso
A. Laso
RMR. Martinez
R. Martinez

17 June 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
RMRaquel Martinez
Raquel Martinez
Pablo CastroPablo Castro
Pablo Castro
AAAlberto Arroyo
Alberto Arroyo
Mario MananaMario Manana
Mario Manana
NGnoemi galan
noemi galan
ALAlberto Laso
Alberto Laso
The complexity in the power system topology, together with the new paradigm in generation and demand, make achieving an adequate level of supply quality a complicated goal for distribution companies. The electrical system power quality is subject to different regulations. On one hand, EN-50160 establishes the characteristics of the voltage supplied by public electricity networks, therefore affecting distribution companies. On the other hand, the EN-61000 series of standards regulates the electromagnetic compatibility of devices connected to the network, therefore affecting the loads. Power companies and device manufacturers are both responsible and affected in the issue of quality of supply. Despite the regulations, there are certain aspects of the supply quality that are not solved. One of the most important is the location of the disturbance’s origin. This paper presents a review of the main techniques to locate the disturbance’s origin in the electric network through two approaches: identification of the disturbance’s cause and the location of the origin.

6 May 2024 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Open access
Sergio BustamanteSergio Bustamante
Sergio Bustamante
Mario MananaMario Manana
Mario Manana
AAAlberto Arroyo
Alberto Arroyo
ALAlberto Laso
Alberto Laso
RMRaquel Martinez
Raquel Martinez
1

13 December 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Sergio BustamanteSergio Bustamante
Sergio Bustamante
Mario MananaMario Manana
Mario Manana
AAAlberto Arroyo
Alberto Arroyo
ALAlberto Laso
Alberto Laso
RMRaquel Martinez
Raquel Martinez
Power transformers are considered to be the most important assets in power substations. Thus, their maintenance is important to ensure the reliability of the power transmission and distribution system. One of the most commonly used methods for managing the maintenance and establishing the health status of power transformers is dissolved gas analysis (DGA). The presence of acetylene in the DGA results may indicate arcing or high-temperature thermal faults in the transformer. In old transformers with an on-load tap-changer (OLTC), oil or gases can be filtered from the OLTC compartment to the transformer’s main tank. This paper presents a method for determining the transformer oil contamination from the OLTC gases in a group of power transformers for a distribution system operator (DSO) based on the application of the guides and the knowledge of experts. As a result, twenty-six out of the 175 transformers studied are defined as contaminated from the OLTC gases. In addition, this paper presents a methodology based on machine learning techniques that allows the system to determine the transformer oil contamination from the DGA results. The trained model achieves an accuracy of 99.76% in identifying oil contamination.

14 February 2025 in Energies
Verified
Journal Article
Open access
PDF file
LFLuis Vejo Fernández
Luis Vejo Fernández
Pablo CastroPablo Castro
Pablo Castro
Mario MananaMario Manana
Mario Manana
ALAlberto Laso
Alberto Laso
RAMON LECUNARAMON LECUNA
RAMON LECUNA
ESEugenio Sainz
Eugenio Sainz
This study presents an analysis of ampacity evaluation techniques in overhead transmission lines based on methods for calculating conductor capacity through static and dynamic line rating analysis. It is specifically applied to high-temperature low-sag (HTLS) conductors, comparing theoretical results with empirically obtained real-time measurements. International standard methodologies, such as those from the IEEE and CIGRE, are examined to assess the impact of meteorological conditions on the performance of overhead transmission lines. Theoretical analyses are contrasted with experimental results obtained through a physical simulation prototype designed specifically for this purpose. A comparative analysis is presented that evaluates the deviations in conventional ampacity calculation techniques based on conductor temperature, comparing them with their performance in experimental situations for High-Temperature Low-Sag conductors under high load demand. This research offers an analytical perspective for optimizing the performance of transmission lines through the use of high-density currents. The results analyze the accuracy of calculation methodologies under different load and environmental scenarios, identifying conditions with the highest deviations, to enable more efficient and secure management in high-demand scenarios.