Andrea Firrincieli

Mr. Andrea Firrincieli

The Biorobotics Institute - Scuola Superiore Sant'Anna
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 September 2020 in Cancers
Verified
Journal Article
Open access
PDF file
MVMauro Verra
Mauro Verra
Andrea FirrincieliAndrea Firrincieli
Andrea Firrincieli
Marcello ChiurazziMarcello Chiurazzi
Marcello Chiurazzi
AMAndrea Mariani
Andrea Mariani
GSGiacomo Lo Secco
Giacomo Lo Secco
AAAlberto Arezzo
Alberto Arezzo
Background and Aims: Colorectal cancer (CRC) is a major cause of morbidity and mortality worldwide. Despite offering a prime paradigm for screening, CRC screening is often hampered by invasiveness. Endoo is a potentially painless colonoscopy method with an active locomotion tethered capsule offering diagnostic and therapeutic capabilities. Materials and Methods: The Endoo system comprises a soft-tethered capsule, which embeds a permanent magnet controlled by an external robot equipped with a second permanent magnet. Capsule navigation is achieved via closed-loop interaction between the two magnets. Ex-vivo tests were conducted by endoscopy experts and trainees to evaluate the basic key features, usability, and compliance in comparison with conventional colonoscopy (CC) in feasibility and pilot studies. Results: Endoo showed a 100% success rate in operating channel and target approach tests. Progression of the capsule was feasible and repeatable. The magnetic link was lost an average of 1.28 times per complete procedure but was restored in 100% of cases. The peak value of interaction forces was higher in the CC group than the Endoo group (4.12N vs. 1.17N). The cumulative interaction forces over time were higher in the CC group than the Endoo group between the splenic flexure and mid-transverse colon (16.53Ns vs. 1.67Ns, p < 0.001), as well as between the hepatic flexure and cecum (28.77Ns vs. 2.47Ns, p = 0.005). The polyp detection rates were comparable between groups (9.1 ± 0.9% vs. 8.7 ± 0.9%, CC and Endoo respectively, per procedure). Robotic colonoscopies were completed in 67% of the procedures performed with Endoo (53% experts and 100% trainees). Conclusions: Endoo allows smoother navigation than CC and possesses comparable features. Although further research is needed, magnetic capsule colonoscopy demonstrated promising results compared to CC.

12 September 2011 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
AAAlireza Alian
Alireza Alian
GBGuy Brammertz
Guy Brammertz
CMClement Merckling
Clement Merckling
Andrea FirrincieliAndrea Firrincieli
Andrea Firrincieli
WWWei Wang
Wei Wang
MHMarc Heyns
Marc Heyns
The efficiency of the ammonium sulfide vapor (ASV) treatment, as opposed to the wet treatment in the liquid ammonium sulfide solution, on the performance improvement of the In0.53Ga0.47As surface-channel as well as InP-capped buried-channel metal-oxide-semiconductor field-effect-transistors (MOSFET) was demonstrated for the first time. MOSFETs were fabricated with either HCl or ASV surface treatments prior to the gate oxide deposition. ASV treatment was found to be very efficient in boosting the drive current of the transistors compared to that of the HCl treatment. It was also found that the ASV treatment leads to a lower border trap density and slightly higher oxide/semiconductor interface defect density compared to that of the HCl treatment. X-ray photoelectron spectroscopy (XPS) studies of In0.53Ga0.47As native oxide regrowth after both surface treatments identified indium sub-oxides as a possible cause of the performance degradation of the HCl treated devices. Based on this work, ASV treatment could be an efficient solution to the passivation of III-V surfaces.

15 October 2006 in Materials Science Forum
Verified
Journal Article
Closed access
PDF file
Francesco La ViaFrancesco La Via
Francesco La Via
GGG. Galvagno
G. Galvagno
Andrea FirrincieliAndrea Firrincieli
Andrea Firrincieli
Fabrizio RoccaforteFabrizio Roccaforte
Fabrizio Roccaforte
SFSalvatore Di Franco
Salvatore Di Franco
DCDanilo Crippa
Danilo Crippa
The growth rate of 4H-SiC epi layers has been increased by a factor 3 (up to 18μm/h) with respect to the standard process with the introduction of HCl in the deposition chamber. The epitaxial layers grown with the addition of HCl have been characterized by electrical, optical and structural characterization methods. An optimized process without the addition of HCl is reported for comparison. The Schottky diodes, manufactured on the epitaxial layer grown with the addition of HCl at 1600 °C, have electrical characteristics comparable with the standard epitaxial process with the advantage of an epitaxial growth rate three times higher.

1 September 2014
Verified
Conference Paper
Closed access
AHA. S. Hassan
A. S. Hassan
Andrea FirrincieliAndrea Firrincieli
Andrea Firrincieli
CMC. Marmaras
C. Marmaras
LCLiana Cipcigan
Liana Cipcigan
MPM.A. Pastorelli
M.A. Pastorelli
Integration of renewable energy sources and Electric Vehicles (EVs) into a micro-grid was modeled. Time Series load flow for summer and winter load profiles was carried out. The voltage profiles over 24 hour period were evaluated for different Distributed Generators (DGs) and EV penetration. Uncontrolled and dual tariff EV charging were considered. The results indicate that voltage drops are less significant for the dual-tariff EV charging regime with increasing levels of DG penetration. Energy losses decrease in the case of dual tariff charging with maximum network loading (winter maximum load).

1 April 2021 in Tribology International
Verified
Journal Article
Closed access
JAJoan Ortega Alcaide
Joan Ortega Alcaide
YHYu Huan
Yu Huan
NGNoemi Gabrieli
Noemi Gabrieli
Andrea FirrincieliAndrea Firrincieli
Andrea Firrincieli
LRLeonardo Ricotti
Leonardo Ricotti
GCGastone Ciuti
Gastone Ciuti

19 October 2023 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Open access
YHYu Huan
Yu Huan
XRXuyang Ren
Xuyang Ren
Andrea FirrincieliAndrea Firrincieli
Andrea Firrincieli
Luigi ManfrediLuigi Manfredi
Luigi Manfredi
Matteo CianchettiMatteo Cianchetti
Matteo Cianchetti
GCGastone Ciuti
Gastone Ciuti
Soft-tethered colonoscopes were proposed for safe and effective colon navigation, yet the deployment of front-wheel actuated colonoscopes is hindered by contact interactions with the lumen along the entire soft tether. To mitigate this problem, this study introduces an over-the-tube flexible device aimed to assist colonoscope deployment. The device is composed of three pneumatically driven actuators devised to repeatedly perform a two-phase operation: (phase I) to advance along the tether up to a working position relatively close to the colonoscope's tip; (phase II) to clamp and drag the tether forward, upon anchoring to the colonic wall. This way, a distal tether portion is freed, thus reducing the aforementioned limitations and fostering effective front-wheel navigation. Considering anatomical/clinical constraints and a 2N resistive force, we designed and prototyped a system with an inner and outer diameter of 12 and 26 mm, respectively, a length of 91 mm, and operating pressures equal to 150, 50, and 15 kPa for clamping the tether, elongating the device and safely anchoring to the colonic wall, respectively. The device was successfully tested, achieving locomotion speeds up to 4.9 and 2.2 mm/s, and tether-freeing rates up to 2.9 and 1.8 mm/s, in tabletop conditions and in a colon phantom, respectively.