Flexible colonoscopy remains the prime mean of screening for colorectal cancer (CRC) and the gold standard of all population-based screening pathways around the world. Almost 60% of CRC deaths could be prevented with screening. However, colonoscopy attendance rates are affected by discomfort, fear of pain and embarrassment or loss of control during the procedure. Moreover, the emergence and global thread of new communicable diseases might seriously affect the functioning of contemporary centres performing gastrointestinal endoscopy. Innovative solutions are needed: artificial intelligence (AI) and physical robotics will drastically contribute for the future of the healthcare services. The translation of robotic technologies from traditional surgery to minimally invasive endoscopic interventions is an emerging field, mainly challenged by the tough requirements for miniaturization. Pioneering approaches for robotic colonoscopy have been reported in the nineties, with the appearance of inchworm-like devices. Since then, robotic colonoscopes with assistive functionalities have become commercially available. Research prototypes promise enhanced accessibility and flexibility for future therapeutic interventions, even via autonomous or robotic-assisted agents, such as robotic capsules. Furthermore, the pairing of such endoscopic systems with AI-enabled image analysis and recognition methods promises enhanced diagnostic yield. By assembling a multidisciplinary team of engineers and endoscopists, the paper aims to provide a contemporary and highly-pictorial critical review for robotic colonoscopes, hence providing clinicians and researchers with a glimpse of the major changes and challenges that lie ahead.
Background and Aims: Colorectal cancer (CRC) is a major cause of morbidity and mortality worldwide. Despite offering a prime paradigm for screening, CRC screening is often hampered by invasiveness. Endoo is a potentially painless colonoscopy method with an active locomotion tethered capsule offering diagnostic and therapeutic capabilities. Materials and Methods: The Endoo system comprises a soft-tethered capsule, which embeds a permanent magnet controlled by an external robot equipped with a second permanent magnet. Capsule navigation is achieved via closed-loop interaction between the two magnets. Ex-vivo tests were conducted by endoscopy experts and trainees to evaluate the basic key features, usability, and compliance in comparison with conventional colonoscopy (CC) in feasibility and pilot studies. Results: Endoo showed a 100% success rate in operating channel and target approach tests. Progression of the capsule was feasible and repeatable. The magnetic link was lost an average of 1.28 times per complete procedure but was restored in 100% of cases. The peak value of interaction forces was higher in the CC group than the Endoo group (4.12N vs. 1.17N). The cumulative interaction forces over time were higher in the CC group than the Endoo group between the splenic flexure and mid-transverse colon (16.53Ns vs. 1.67Ns, p < 0.001), as well as between the hepatic flexure and cecum (28.77Ns vs. 2.47Ns, p = 0.005). The polyp detection rates were comparable between groups (9.1 ± 0.9% vs. 8.7 ± 0.9%, CC and Endoo respectively, per procedure). Robotic colonoscopies were completed in 67% of the procedures performed with Endoo (53% experts and 100% trainees). Conclusions: Endoo allows smoother navigation than CC and possesses comparable features. Although further research is needed, magnetic capsule colonoscopy demonstrated promising results compared to CC.
23 November 2021 in IEEE Transactions on Automation Science and Engineering
Quality control in industry involves trained operators to manipulate and inspect metallic surfaces in order to identify, and eventually correct, manufacturing defects. These tasks are manually performed, and a poor performance (e.g., missing defects) leads to an increase of the costs and prolongation of the manufacturing time cycle. In this work, we propose a multi-agent robotic platform to autonomously perform Industry 4.0 quality control processes of metallic surfaces. The platform consists of three anthropomorphic robots with custom-made end-effectors designed to manipulate, inspect, and eventually correct a metallic frame of a motorcycle. The description of a novel multi-agent platform is followed by the presentation of the developed inspection procedure, in which a linear laser scanner is used to reconstruct the three-dimensional metallic surface of a motorcycle with a resolution of ~0.1 mm. In order to validate the platform, we perform a set of experiments to assess the performance of the robotic platform in a real Industry 4.0 scenario. Results confirmed that such a system guarantees a sub-millimetric precision to identify defects on complex-shaped metallic surfaces and effectively correct them. The proposed robotic platform can be adopted for overcoming the drawbacks of a traditional procedure that relies on visual-tactile manual defects correction (e.g., low-repeatability, high-subjectivity) and is scalable to different industrial applications. The proposed approach aims to elevate the role of operators to expert supervisors of the process, limiting the interactions with potentially-dangerous tools/procedures and thus improving the working conditions in an industrial 4.0 scenario.
In this paper, the authors developed a capacitive-based sensor technology for high-range proximity detection, composed of multiple active units. The single sensor unit consists of a multi-layer compliant structure with a coplanar plate capacitor configuration. A prototype, composed of two single active units, was designed using, for each one, conductive electrodes printed on a polyimide layer and positioned in the middle of soft polymeric insulating substrates, either acting as shock-absorber and for sensor electrical and mechanical protection. For an in-depth theoretical analysis of the physical capacitive principle, a conditioning electronic circuit (i.e. data collection, conversion, amplification and filtering modules) was built in order to collect a digital voltage output proportional to the variable sensed capacitance. Experiments were performed to characterize the single capacitive sensor and the multi-unit sensor technology (i.e. curve of response, dynamic response, accuracy and precision). The results confirmed the outcomes originally achieved through FEM simulations and the effectiveness of the technology in high-range detection. Using a combination of two active sensor units, an operating range was achieved of up to 15 times the performance of a single commercial capacitive sensor with comparable dimensions.
The healing process of surgically-stabilised long bone fractures depends on two main factors: (a) the assessment of implant stability, and (b) the knowledge of bone callus stiffness. Currently, X-rays are the main diagnostic tool used for the assessment of bone fractures. However, they are considered unsafe, and the interpretation of the clinical results is highly subjective, depending on the clinician’s experience. Hence, there is the need for objective, non-invasive and repeatable methods to allow a longitudinal assessment of implant stability and bone callus stiffness. In this work, we propose a compact and scalable system, based on capacitive sensor technology, able to measure, quantitatively, the relative pins displacements in bone fractures treated with external fixators. The measurement device proved to be easily integrable with the external fixator pins. Smart arrangements of the sensor units were exploited to discriminate relative movements of the external pins in the 3D space with a resolution of 0.5 mm and 0.5°. The proposed capacitive technology was able to detect all of the expected movements of the external pins in the 3D space, providing information on implant stability and bone callus stiffness.
10 November 2020 in IEEE Transactions on Medical Robotics and Bionics
An endoscopic tactile robotic capsule, embedding miniaturized MEMS force sensors, is presented. The capsule is conceived to provide automatic palpation of non-polypoid colorectal tumours during colonoscopy, since it is characterized by high degree of dysplasia, higher invasiveness and lower detection rates with respect to polyps. A first test was performed employing a silicone phantom that embedded inclusions with variable hardness and curvature. A hardness-based classification was implemented, demonstrating detection robustness to curvature variation. By comparing a set of supervised classification algorithms, a weighted 3-nearest neighbor classifier was selected. A bias force normalization model was introduced in order to make different acquisition sets consistent. Parameters of this model were chosen through a particle swarm optimization method. Additionally, an ex-vivo test was performed to assess the capsule detection performance when magnetically driven along a colonic tissue. Lumps were identified as voltage peaks with a prominence depending on the total magnetic force applied to the capsule. 94% accuracy in hardness classification was achieved, while a 100% accuracy is obtained for the lump detection within a tolerance of 5 mm from the central path described by the capsule. In real application scenario, we foresee our device aiding physicians to detect tumorous tissues.