Héctor Pérez-Cejuela

Mr. Héctor Pérez-Cejuela

University of Valencia
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2024 in Analytical Chemistry
Verified
Journal Article
Closed access
HPHéctor Pérez-Cejuela
Héctor Pérez-Cejuela
Emanuela GionfriddoEmanuela Gionfriddo
Emanuela Gionfriddo

14 September 2020 in Molecules
Verified
Journal Article
Open access
PDF file
HPHéctor Pérez-Cejuela
Héctor Pérez-Cejuela
Jose Manuel Herrero-MartinezJose Manuel Herrero-Martinez
Jose Manuel Herrero-Martinez
ESErnesto F. Simó-Alfonso
Ernesto F. Simó-Alfonso
This review summarizes the recent advances concerning metal–organic frameworks (MOFs) modified with several biomolecules (e.g., amino acids, nucleobases, proteins, antibodies, aptamers, etc.) as ligands to prepare affinity-based sorbents for application in the sample preparation field. The preparation and incorporation strategies of these MOF-based affinity materials were described. Additionally, the different types of ligands that can be employed for the synthesis of these biocomposites and their application as sorbents for the selective extraction of molecules and clean-up of complex real samples is reported. The most important features of the developed biocomposites will be discussed throughout the text in different sections, and several examples will be also commented on in detail.

7 February 2022 in Microchimica Acta
Verified
Journal Article
Open access
PDF file
SZS. Zatrochová
S. Zatrochová
HPHéctor Pérez-Cejuela
Héctor Pérez-Cejuela
MIMónica Catalá Icardo
Mónica Catalá Icardo
ESErnesto F. Simó-Alfonso
Ernesto F. Simó-Alfonso
ILIvona Lhotská
Ivona Lhotská
Jose Manuel Herrero-MartinezJose Manuel Herrero-Martinez
Jose Manuel Herrero-Martinez
A novel coating based on hybrid monolith with metal–organic framework (MOF) onto conventional Teflon-coated magnetic stir bars was developed. For this purpose, the external surface of the Teflon stir bar was firstly vinylized in order to immobilize a glycidyl methacrylate (GMA)–based polymer onto the magnet. Then, an amino-modified MOF of type MIL-101 (NH2-MIL-101(Al)) was covalently attached to the GMA-based monolith. After the synthesis process, several parameters affecting extraction of target estrogens by stir bar sorptive extraction (SBSE) including pH, ionic strength, extraction time, stirring rate, desorption solvent, and desorption time were also investigated. The resulting hybrid monolith was evaluated as SBSE sorbent for extraction of three estrogens (estrone, 17β-estradiol, estriol) and synthetic 17β-ethinylestradiol from water and human urine samples followed by HPLC with fluorescence detection (excitation and emission wavelengths, 280 and 310 nm, respectively). Under the optimal experimental conditions, the analytical figures of the method were established, achieving satisfactory limits of detection in the range of 0.015–0.58 µg L−1, recovery results ranging from 70 to 95% with RSD less than 6%, and precision values (intra- and inter-extraction units) below 6%. Graphical abstract

26 May 2021 in Microchimica Acta
Verified
Journal Article
Closed access
PDF file
HPHéctor Pérez-Cejuela
Héctor Pérez-Cejuela
KPKateřina Pravcová
Kateřina Pravcová
LČLenka Česlová
Lenka Česlová
ESErnesto F. Simó-Alfonso
Ernesto F. Simó-Alfonso
Jose Manuel Herrero-MartinezJose Manuel Herrero-Martinez
Jose Manuel Herrero-Martinez


1 April 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
HPHéctor Pérez-Cejuela
Héctor Pérez-Cejuela
MCMaria Maddalena Calabretta
Maria Maddalena Calabretta
Valerio BocciValerio Bocci
Valerio Bocci
MDMarcello D’elia
Marcello D’elia
Elisa MicheliniElisa Michelini
Elisa Michelini
Adenosine triphosphate (ATP) determination has been used for many decades to assess microbial contamination for hygiene monitoring in different locations and workplace environments. Highly sophisticated methods have been reported, yet commercially available kits rely on a luciferase–luciferin system and require storage and shipping at controlled temperatures (+4 or −20 °C). The applicability of these systems is limited by the need for a secure cold chain, which is not always applicable, especially in remote areas or low-resource settings. In this scenario, easy-to-handle and portable sensors would be highly valuable. Prompted by this need, we developed a bioluminescence paper biosensor for ATP monitoring in which a new luciferase mutant was combined with a metal–organic framework (MOF); i.e., zeolitic imidazolate framework-8 (ZIF-8). A paper biosensor was developed, ZIF-8@Luc paper sensor, and interfaced with different portable light detectors, including a silicon photomultiplier (SiPM) and smartphones. The use of ZIF-8 not only provided a five-fold increase in the bioluminescence signal, but also significantly improved the stability of the sensor, both at +4 and +28 °C. The ATP content in complex biological matrices was analyzed with the ZIF-8@Luc paper sensor, enabling detection down to 7 × 10−12 moles of ATP and 8 × 10−13 moles in bacterial lysates and urine samples, respectively. The ZIF-8@Luc sensor could, therefore, be applied in many fields in which ATP monitoring is required such as the control of microbial contamination.