Young-Jin Baik

Young-Jin Baik


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2020 in Energy Conversion and Management
Verified
Journal Article
Closed access
HMHafiz Ali Muhammad
Hafiz Ali Muhammad
HSHaider Sultan
Haider Sultan
BLBeomjoon Lee
Beomjoon Lee
Muhammad ImranMuhammad Imran
Muhammad Imran
IBIl Hyun Baek
Il Hyun Baek
SNSung Chan Nam
Sung Chan Nam

1 February 2020 in Energy Conversion and Management
Verified
Journal Article
Closed access
HMHafiz Ali Muhammad
Hafiz Ali Muhammad
CRChulwoo Roh
Chulwoo Roh
JCJongjae Cho
Jongjae Cho
ZRZabdur Rehman
Zabdur Rehman
HSHaider Sultan
Haider Sultan
BLBeomjoon Lee
Beomjoon Lee

1 November 2019 in Energy Conversion and Management
Verified
Journal Article
Closed access
SNSun-Ik NA
Sun-Ik NA
MKMin Soo Kim
Min Soo Kim
YBYoung-Jin Baik
Young-Jin Baik
MKMinsung Kim
Minsung Kim

21 January 2015 in Heat Transfer Engineering
Verified
Journal Article
Closed access
MKMinsung Kim
Minsung Kim
GLGilbong Lee
Gilbong Lee
YBYoung-Jin Baik
Young-Jin Baik
HRHo-Sang Ra
Ho-Sang Ra
Vertical closed-loop groun-source heat pump systems have been installed widely in Korea since they can extract a moderate temperature level of geothermal heat in a relatively small area. For a ground heat exchanger, a vertical closed-loop type with brine circulation is mostly preferred since it is simpler and less harmful to the ground environment. However, it requires a secondary loop between the refrigerant in a heat pump and the brine. By adding a geothermal heat exchanger in the secondary heat exchange loop, circulation pumps should be attached and the temperature difference between refrigerant and ground would be increased, which causes performance degradation. In this paper, performances of direct expansion ground-source heat pump were evaluated mathematically as an alternative to the conventional secondary-loop ground-source heat pump.

1 December 2019 in Renewable Energy
Verified
Journal Article
Closed access
HMHafiz Ali Muhammad
Hafiz Ali Muhammad
BLBeomjoon Lee
Beomjoon Lee
GLGilbong Lee
Gilbong Lee
JCJunhyun Cho
Junhyun Cho
YBYoung-Jin Baik
Young-Jin Baik

9 November 2020 in Energies
Verified
Journal Article
Open access
PDF file
HMHafiz Ali Muhammad
Hafiz Ali Muhammad
Hafiz Muhammad Abdullah MalikHafiz Muhammad Abdullah Malik
Hafiz Muhammad Abdullah Malik
ZRZabdur Rehman
Zabdur Rehman
BLBeomjoon Lee
Beomjoon Lee
YBYoung-Jin Baik
Young-Jin Baik
MBMuhammad Shoaib Butt
Muhammad Shoaib Butt
An ejector is a simple mechanical device that can be integrated with power generation or the refrigeration cycle to enhance their performance. Owing to the complex flow behavior in the ejector, the performance prediction of the ejector is done by numerical simulations. However, to evaluate the performance of an ejector integrated power cycle or refrigeration cycle, the need for simpler and more reliable thermodynamic models to estimate the performance of the ejector persists. This research, therefore, aims at developing a single mathematical correlation that can predict the ejector performance with reasonable accuracy. The proposed correlation relates the entrainment ratio and the pressure rise across the ejector to the area ratio and the mass flow rate of the primary flow. R141b is selected as the ejector refrigerant, and the results obtained through the proposed correlation are validated through numerical solutions. The comparison between the analytical and numerical with experimental results provided an error of less than 8.4% and 4.29%, respectively.