This paper proposes a dual-parameters compensation control method to improve the torque accuracy of permanent magnet synchronous motor~(PMSM) in flux-weakening region for rail transit. For the sake of the feature that six-step operation is the essential operation of rail transit and switching frequency is very low, the proposed method works on the single q-axis current regulator-variable voltage angle~(SQCR-VVA) flux-weakening control strategy of PMSM. Based on SQCR-VVA flux-weakening control, impact of inaccurate parameters is analysed in seven different conditions, and inaccurate parameters (d-axis inductance, q-axis inductance and permanent magnet flux linkage) result in the errors on d-axis current response and d-axis feed forward voltage. In order to eliminate the impact of the three parameters at the same time, two compensation regulators are applied to the proposed method. Error of q-axis inductance is identified by the d-axis voltage regulator. Impact of d-axis inductance and permanent magnet flux linkage is eliminated by the d-axis current regulator. The proposed method is subsequently tested on PMSM and shows quite good performance on the improvement of torque accuracy.
6 August 2019 in IEEE Transactions on Power Electronics
Starting in the rotating condition is an important technology for induction motor (IM) speed sensorless control. The key of this technology is that the initial speed of the IM in the rotating condition should be estimated quickly and accurately. In this paper, an integral sliding mode (ISM) control method based on the nonlinear model of the rotor back electromotive force (back-EMF) is designed to start a speed sensorless controlled IM in the rotating condition. The stability is guaranteed by Lyapunov stability analysis, and the robustness to rotor time constant and disturbance are analyzed. Meanwhile, in comparison with the proposed control method, the existing input-output feedback linearization (IOFL) control method is introduced and the stability and robustness are also analyzed. Compared with the existing IOFL control method, the proposed control method can estimate the initial speed in the rotating condition without overshoot and has better dynamic performance and robustness. In addition, the proposed control method can be applied not only to the restart operation but also to the normal operation. Only a single control strategy is required from the restart operation to the normal operation. The proposed method is verified by simulation and experiments using a 7.5kW induction motor.
13 March 2023 in IEEE Transactions on Industrial Electronics
Single current regulator (SCR) control is a popular flux-weakening control for permanent magnet synchronous motor (PMSM), which can maintain the output voltage amplitude constant at the maximum value (suitable for square-wave mode), while providing well dynamic performance. Currently, four kinds of SCR control have been proposed separately from different views. The principle of SCR control is summarized from a novel view in this article. Based on that, another two SCR methods are derived naturally, which is single q -axis current regulator-regulates d -axis and q -axis voltage(SQCR-RDV and SQCR-RQV) methods respectively. More than that, the issue of current regulator structure is discussed in detail. Small signal analysis is adopted to test the system stability while the proper and improper regulators are applied. The influence of the unstable operation is also analyzed by the current locus. Then, appropriate SCR methods are recommended for finite and infinite speed PMSM. The analyses are verified by simulation and experimental results.
6 November 2023 in IEEE Transactions on Transportation Electrification
High-frequency (HF) voltage injection methods are usually used in sensorless control for interior permanent magnet synchronous motor (IPMSM) at low-speed. The stator resistance is ignored when the frequency of HF voltage is high enough. However, in high power application, the frequency of injected voltage becomes low limited to low switching frequency, which leads to rotor position estimation error due to ignoring stator resistance. Moreover, the phase delays caused by the filter and large system delay under low switching frequency bring estimation error, which changes with speed and cannot be directly compensated. Therefore, this paper proposes a sensorless control by injecting HF voltage at one-third of switching frequency. To reduce the influence of stator resistance on estimated result, the HF current generated by the 5th harmonic of injected HF voltage is adopted to estimate rotor position, which increases the equivalent frequency of HF signal. To eliminate the estimation error caused by filter and system delay, an adaptive compensation strategy for total disturbance is applied. Besides, the voltage and generated current at injection frequency are adopted to identify the stator inductance by recursive least squares, which improves the performance of torque control. The proposed methods are verified by simulation and experimental.
5 July 2024 in IEEE Transactions on Energy Conversion
This paper proposes an improved hybrid sensorless control method for interior permanent magnet synchronous motor (IPMSM) in full speed range at low switching frequency. At low speed, the conventional high-frequency (HF) voltage injection method is difficult to implement at low switching frequency because of the special dual sampling rate mechanism. Therefore, this paper proposes an improved square wave voltage injection method, which separates the observation of rotor position from the injection of HF voltage and the extraction of HF current based on dual sampling rate mechanism. Then, the error caused by large PWM delay at low switching frequency is analyzed and compensated. At high speed, to avoid the influence of cross coupling due to discretization error on the estimated rotor position at low switching frequency, the cross coupling caused by modeling in continuous time domain is analyzed, then a state observer is established in discrete time domain directly. A 3 kW experimental platform is built to verify the effectiveness of proposed method.
4 March 2024 in IEEE Transactions on Transportation Electrification
The overmodulation (OVM) technique is commonly adopted to fully improve the dc-bus utilization. In this paper, a comprehensive investigation of different OVM methods for the dual three-phase motor drive is conducted in terms of current distortion. To provide the benchmark of the actual minimum current distortion (MCD), the MCD OVM method is proposed based on the space vector concept, which leads to an optimization problem with reduced computational complexity. Moreover, the well-known three-phase OVM methods are extended to the dual three-phase motor drive for more choices in the OVM range. A thorough performance comparison of the OVM methods provides meaningful information for improved OVM operation. Simulation and experimental results on a 7.5-kW dual three-phase induction motor drive are given to confirm the correctness of the theoretical analysis and the validity of the proposed MCD OVM.