12 September 2022 in IEEE Transactions on Transportation Electrification
LLC -DC transformers ( LLC -DCXs) operate under fixed-frequency and open-loop conditions to achieve high efficiency and are promising converters that can be used in the auxiliary power units (APUs) of electric locomotives. An optimal design method of LLC -DCXs is proposed in this paper. First, the time-domain expressions of the symmetric half-bridge LLC resonant converter with split resonant capacitors are derived. A current increment method is proposed to determine the expressions. Second, the discontinuous conduction mode (DCM) and voltage gain limiting conditions are used to obtain the magnetizing inductance ranges. The converter losses and zero-voltage-switching (ZVS) ranges are considered to determine the final magnetizing inductance. A 10 kW prototype is used as an example, and a detailed parameter design process is implemented. Compared with conventional design methods for the magnetizing inductance, the proposed method can effectively determine the maximum magnetizing inductance for the DCM operation of the converter. The effectiveness of the proposed method is proven by the simulations and experimental results obtained for the 10 kW LLC -DCX prototype. The maximum efficiency of the designed converter is 98.12% under the full load.
11 November 2019 in IEEE Transactions on Power Electronics
Power electronic traction transformer (PETT) is a module-cascaded converter with high-frequency-link technology to realize high power conversion. A typical structure of PETT contains a single-phase cascaded H-bridge rectifier in the first stage and several dual active full-bridge DC-DC converters in the second stage. For PETT adopting such complex topological structure, the control strategy also becomes complicated and should be carefully designed. In this paper, a power-linked predictive control strategy for PETT is proposed based on the predictive controls of H-bridge rectifier and dual active full-bridge DC-DC converter. A power link is brought into the control strategy to connect H-bridge rectifier with DC-DC converter, through which the input power of PETT can match the output power. Moreover, the voltage balance control and power balance control are also combined with predictive control by power-linked predictive control strategy. Using such strategy, the fluctuation of H-bridge rectifier DC voltage is suppressed, the circumfluence among modules is reduced, and the dynamic and steady-state performances are both improved compared with traditional strategy. Simulation and experimentation platforms with both resistance load and motor load are built to show the effectiveness and correctness of power-linked predictive control strategy.
23 August 2022 in IEEE Transactions on Power Electronics
The superior characteristics of the silicon carbide metal-oxide-semiconductor field-effect transistor (SiC mosfet ) allow its wide use for improving the efficiency and power density of power electronic systems. However, the higher switching speed exacerbates the problems of overshoot, oscillation, and electromagnetic interference (EMI), which need to be properly addressed. In this article, a novel stage-detection closed-loop active gate driver (AGD) based on the printed-circuit-board (PCB) Rogowski Coil is proposed for optimizing the switching performance of SiC mosfet s. And its stage identification threshold design can weaken the influence of the varying nonlinear parameters, especially for the turn- on process. First, the gate driver trajectory and the switching process of the SiC mosfet are analyzed. The optimal driver parameter dynamic configuration among the existing stage-control schemes is defined and unified, which aims to optimize the tradeoff between the overshoot and switching loss. Then, the parameter design of the PCB Rogowski Coil is illustrated. And the operation principle and working process of the proposed AGD are introduced. Finally, the performance of the proposed AGD and the effectiveness of the stage-control schemes are verified in the double-pulse test under different conditions. The experimental results show that the proposed AGD can not only reduce the overshoot and suppress the oscillation but also optimize the compromise of the switching loss and switching time.
13 April 2020 in IEEE Transactions on Power Electronics
This paper proposes a dual-parameters compensation control method to improve the torque accuracy of permanent magnet synchronous motor~(PMSM) in flux-weakening region for rail transit. For the sake of the feature that six-step operation is the essential operation of rail transit and switching frequency is very low, the proposed method works on the single q-axis current regulator-variable voltage angle~(SQCR-VVA) flux-weakening control strategy of PMSM. Based on SQCR-VVA flux-weakening control, impact of inaccurate parameters is analysed in seven different conditions, and inaccurate parameters (d-axis inductance, q-axis inductance and permanent magnet flux linkage) result in the errors on d-axis current response and d-axis feed forward voltage. In order to eliminate the impact of the three parameters at the same time, two compensation regulators are applied to the proposed method. Error of q-axis inductance is identified by the d-axis voltage regulator. Impact of d-axis inductance and permanent magnet flux linkage is eliminated by the d-axis current regulator. The proposed method is subsequently tested on PMSM and shows quite good performance on the improvement of torque accuracy.
6 August 2019 in IEEE Transactions on Power Electronics
Starting in the rotating condition is an important technology for induction motor (IM) speed sensorless control. The key of this technology is that the initial speed of the IM in the rotating condition should be estimated quickly and accurately. In this paper, an integral sliding mode (ISM) control method based on the nonlinear model of the rotor back electromotive force (back-EMF) is designed to start a speed sensorless controlled IM in the rotating condition. The stability is guaranteed by Lyapunov stability analysis, and the robustness to rotor time constant and disturbance are analyzed. Meanwhile, in comparison with the proposed control method, the existing input-output feedback linearization (IOFL) control method is introduced and the stability and robustness are also analyzed. Compared with the existing IOFL control method, the proposed control method can estimate the initial speed in the rotating condition without overshoot and has better dynamic performance and robustness. In addition, the proposed control method can be applied not only to the restart operation but also to the normal operation. Only a single control strategy is required from the restart operation to the normal operation. The proposed method is verified by simulation and experiments using a 7.5kW induction motor.
3 May 2021 in IEEE Transactions on Power Electronics
Transient DC bias current will appear in dual active bridge (DAB) DC-DC converter when power changes, may resulting in transformer core saturation. Traditionally, a transitional period with extra calculation is added in the transient process to keep the voltage-second balance and eliminate the DC bias current for DAB converter. In this paper, the modulation process rather than the phase-shift control is concerned, and the transient DC bias current can be reduced or even eliminated by staggering the load time of primary bridge and secondary bridge compare values. Modulation scheme with this modification do not need any transitional period or extra calculation, and the time delay in closed-loop control is a constant and smaller than the previous schemes. Besides, as only the load time is modified, the modulation scheme can be implemented in all the phase-shift control methods and the whole operation range. Experimental results verify the theoretical analysis and show the practical feasibility of the modified modulation schemes.