Giacomo Spigler

Dr. Giacomo Spigler

Tilburg University

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 April 2019 in IEEE Transactions on Pattern Analysis and Machine Intelligence
Verified
Journal Article
Closed access
GSGiacomo Spigler
Giacomo Spigler
Despite recent developments that allowed neural networks to achieve impressive performance on a variety of applications, these models are intrinsically affected by the problem of overgeneralization, due to their partitioning of the full input space into the fixed set of target classes used during training. Thus it is possible for novel inputs belonging to categories unknown during training or even completely unrecognizable to humans to fool the system into classifying them as one of the known classes, even with a high degree of confidence. This problem can lead to security problems in critical applications, and is closely linked to open set recognition and 1-class recognition. This paper presents a novel way to compute a confidence score using the reconstruction error of denoising autoencoders and shows how it can correctly identify the regions of the input space close to the training distribution. The proposed solution is tested on benchmarks of fooling, open set recognition and 1-class recognition constructed from the MNIST and Fashion-MNIST datasets.

24 April 2020 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
ICIlaria Cesini
Ilaria Cesini
EMElena Martini
Elena Martini
MFMariangela Filosa
Mariangela Filosa
GSGiacomo Spigler
Giacomo Spigler
Angelo Maria SabatiniAngelo Maria Sabatini
Angelo Maria Sabatini
SCSimona Crea
Simona Crea
The effectiveness of haptic feedback devices highly depends on the perception of tactile stimuli, which differs across body parts and can be affected by movement. In this study, a novel wearable sensory feedback apparatus made of a pair of pressure-sensitive insoles and a belt equipped with vibrotactile units is presented; the device provides time-discrete vibrations around the waist, synchronized with biomechanically-relevant gait events during walking. Experiments with fifteen healthy volunteers were carried out to investigate users’ tactile perception on the waist. Stimuli of different intensities were provided at twelve locations, each time synchronously with one pre-defined gait event (i.e. heel strike, flat foot or toe off), following a pseudo-random stimulation sequence. Reaction time, detection rate and localization accuracy were analyzed as functions of the stimulation level and site and the effect of gait events on perception was investigated. Results revealed that above-threshold stimuli (i.e. vibrations characterized by acceleration amplitudes of 1.92g and 2.13g and frequencies of 100 Hz and 150 Hz, respectively) can be effectively perceived in all the sites and successfully localized when the intertactor spacing is set to 10 cm. Moreover, it was found that perception of time-discrete vibrations was not affected by phase-related gating mechanisms, suggesting that the waist could be considered as a preferred body region for delivering haptic feedback during walking.

1 July 2019 in Neurocomputing
Verified
Journal Article
Closed access
HGHarish Gunasekaran
Harish Gunasekaran
GSGiacomo Spigler
Giacomo Spigler
AMAlberto Mazzoni
Alberto Mazzoni
ECEnrico Cataldo
Enrico Cataldo
Calogero Maria OddoCalogero Maria Oddo
Calogero Maria Oddo

14 October 2020 in Electronics
Verified
Journal Article
Open access
PDF file
ICIlaria Cesini
Ilaria Cesini
GSGiacomo Spigler
Giacomo Spigler
SPSahana Prasanna
Sahana Prasanna
JDJessica D'Abbraccio
Jessica D'Abbraccio
DLDaniela De Luca
Daniela De Luca
Calogero Maria OddoCalogero Maria Oddo
Calogero Maria Oddo
Nowadays, lower-limb prostheses are reaching real-world usability especially on ground-level walking. However, some key tasks such as stair walking are still quite demanding. Providing haptic feedback about the foot placement on the steps might reduce the cognitive load of the task, compensating for increased dependency on vision and lessen the risk of falling. Experiments on intact subjects can be useful to define the feedback strategies prior to clinical trials, but effective methods to assess the efficacy of the strategies are few and usually rely on the emulation of the disability condition. The present study reports on the design and testing of a wearable haptic feedback system in a protocol involving intact subjects to assess candidate strategies to be adopted in clinical trials. The system integrated a sensorized insole wirelessly connected to a textile waist belt equipped with three vibrating motors. Three stimulation strategies for mapping the insole pressure data to vibrotactile feedback were implemented and compared in terms of intuitiveness and comfort perceived during level and stair walking. The strategies were ranked using a relative rating approach, which highlighted the differences between them and suggested guidelines for their improvement. The feedback evaluation procedure proposed could facilitate the selection and improvement of haptic feedback strategies prior to clinical testing.

14 October 2018
Verified
Book Chapter
Closed access
PDF file
ICIlaria Cesini
Ilaria Cesini
GSGiacomo Spigler
Giacomo Spigler
SPSahana Prasanna
Sahana Prasanna
DTDomitilla Taxis
Domitilla Taxis
FDFilippo Dell’agnello
Filippo Dell’agnello
Calogero Maria OddoCalogero Maria Oddo
Calogero Maria Oddo

14 October 2018
Verified
Book Chapter
Closed access
PDF file
MFMariangela Filosa
Mariangela Filosa
ICIlaria Cesini
Ilaria Cesini
EMElena Martini
Elena Martini
GSGiacomo Spigler
Giacomo Spigler
NVNicola Vitiello
Nicola Vitiello
SCSimona Crea
Simona Crea