Ilaria Cesini

Mrs. Ilaria Cesini


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 October 2020 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
EMElena Martini
Elena Martini
ICIlaria Cesini
Ilaria Cesini
JDJessica D'ABbraccio
Jessica D'ABbraccio
GAGabriele Arnetoli
Gabriele Arnetoli
SDStefano Doronzio
Stefano Doronzio
SCSimona Crea
Simona Crea
Gait asymmetry in lower-limb amputees can lead to several secondary conditions that can decrease general health and quality of life. Including augmented sensory feedback in rehabilitation programs can effectively mitigate spatiotemporal gait irregularities. Such benefits can be obtained with non-invasive haptic systems representing an advantageous choice for usability in overground training and every-day life. In this study, we tested a wearable tactile feedback device delivering short-lasting (100 ms) vibrations around the waist syncronized to gait events, to improve the temporal gait symmetry of lower-limb amputees. Three above-knee amputees participated in the study. The device provided bilateral stimulations during a training program that involved ground-level gait training. After three training sessions, participants showed higher temporal symmetry when walking with the haptic feedback in comparison to their natural walking (resulting symmetry index increases of +2.8% for Subject IDA, +12.7% for Subject IDB and +2.9% for Subject IDC). One subject retained improved symmetry (Subject IDB, +14.9%) even when walking without the device. Gait analyses revealed that higher temporal symmetry may lead to concurrent compensation strategies in the trunk and pelvis. Overall, the results of this pilot study confirm the potential utility of sensory feedback devices to positively influence gait parameters when used in supervised settings. Future studies shall clarify more precisely the training modalities and the targets of rehabilitation programs with such devices.

24 April 2020 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
ICIlaria Cesini
Ilaria Cesini
EMElena Martini
Elena Martini
MFMariangela Filosa
Mariangela Filosa
GSGiacomo Spigler
Giacomo Spigler
Angelo Maria SabatiniAngelo Maria Sabatini
Angelo Maria Sabatini
SCSimona Crea
Simona Crea
The effectiveness of haptic feedback devices highly depends on the perception of tactile stimuli, which differs across body parts and can be affected by movement. In this study, a novel wearable sensory feedback apparatus made of a pair of pressure-sensitive insoles and a belt equipped with vibrotactile units is presented; the device provides time-discrete vibrations around the waist, synchronized with biomechanically-relevant gait events during walking. Experiments with fifteen healthy volunteers were carried out to investigate users’ tactile perception on the waist. Stimuli of different intensities were provided at twelve locations, each time synchronously with one pre-defined gait event (i.e. heel strike, flat foot or toe off), following a pseudo-random stimulation sequence. Reaction time, detection rate and localization accuracy were analyzed as functions of the stimulation level and site and the effect of gait events on perception was investigated. Results revealed that above-threshold stimuli (i.e. vibrations characterized by acceleration amplitudes of 1.92g and 2.13g and frequencies of 100 Hz and 150 Hz, respectively) can be effectively perceived in all the sites and successfully localized when the intertactor spacing is set to 10 cm. Moreover, it was found that perception of time-discrete vibrations was not affected by phase-related gating mechanisms, suggesting that the waist could be considered as a preferred body region for delivering haptic feedback during walking.

19 May 2020 in Nanomaterials
Verified
Journal Article
Open access
PDF file
ICIlaria Cesini
Ilaria Cesini
MKMagdalena Kowalczyk
Magdalena Kowalczyk
ALAlessandro Lucantonio
Alessandro Lucantonio
GDGiacomo D’alesio
Giacomo D’alesio
PKPramod Kumar
Pramod Kumar
Calogero Maria OddoCalogero Maria Oddo
Calogero Maria Oddo
Hydrothermal growth of ZnO nanorods has been widely used for the development of tactile sensors, with the aid of ZnO seed layers, favoring the growth of dense and vertically aligned nanorods. However, seed layers represent an additional fabrication step in the sensor design. In this study, a seedless hydrothermal growth of ZnO nanorods was carried out on Au-coated Si and polyimide substrates. The effects of both the Au morphology and the growth temperature on the characteristics of the nanorods were investigated, finding that smaller Au grains produced tilted rods, while larger grains provided vertical rods. Highly dense and high-aspect-ratio nanorods with hexagonal prismatic shape were obtained at 75 °C and 85 °C, while pyramid-like rods were grown when the temperature was set to 95 °C. Finite-element simulations demonstrated that prismatic rods produce higher voltage responses than the pyramid-shaped ones. A tactile sensor, with an active area of 1 cm2, was fabricated on flexible polyimide substrate and embedding the nanorods forest in a polydimethylsiloxane matrix as a separation layer between the bottom and the top Au electrodes. The prototype showed clear responses upon applied loads of 2–4 N and vibrations over frequencies in the range of 20–800 Hz.

14 October 2020 in Electronics
Verified
Journal Article
Open access
PDF file
ICIlaria Cesini
Ilaria Cesini
GSGiacomo Spigler
Giacomo Spigler
SPSahana Prasanna
Sahana Prasanna
JDJessica D'Abbraccio
Jessica D'Abbraccio
DLDaniela De Luca
Daniela De Luca
Calogero Maria OddoCalogero Maria Oddo
Calogero Maria Oddo
Nowadays, lower-limb prostheses are reaching real-world usability especially on ground-level walking. However, some key tasks such as stair walking are still quite demanding. Providing haptic feedback about the foot placement on the steps might reduce the cognitive load of the task, compensating for increased dependency on vision and lessen the risk of falling. Experiments on intact subjects can be useful to define the feedback strategies prior to clinical trials, but effective methods to assess the efficacy of the strategies are few and usually rely on the emulation of the disability condition. The present study reports on the design and testing of a wearable haptic feedback system in a protocol involving intact subjects to assess candidate strategies to be adopted in clinical trials. The system integrated a sensorized insole wirelessly connected to a textile waist belt equipped with three vibrating motors. Three stimulation strategies for mapping the insole pressure data to vibrotactile feedback were implemented and compared in terms of intuitiveness and comfort perceived during level and stair walking. The strategies were ranked using a relative rating approach, which highlighted the differences between them and suggested guidelines for their improvement. The feedback evaluation procedure proposed could facilitate the selection and improvement of haptic feedback strategies prior to clinical testing.

14 October 2018
Verified
Book Chapter
Closed access
PDF file
ICIlaria Cesini
Ilaria Cesini
GSGiacomo Spigler
Giacomo Spigler
SPSahana Prasanna
Sahana Prasanna
DTDomitilla Taxis
Domitilla Taxis
FDFilippo Dell’agnello
Filippo Dell’agnello
Calogero Maria OddoCalogero Maria Oddo
Calogero Maria Oddo

1 June 2020
Verified
Conference Paper
Closed access
Martina ZaltieriMartina Zaltieri
Martina Zaltieri
JTJoshua Di Tocco
Joshua Di Tocco
Daniela Lo PrestiDaniela Lo Presti
Daniela Lo Presti
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
Domenico FormicaDomenico Formica
Domenico Formica
Maria Sabrina  SartoMaria Sabrina Sarto
Maria Sabrina Sarto
Safety at work is driving the development of new technological solutions in the era of Industry 4.0. Among others, systems able to monitor physiological parameters are gaining high relevance since such devices have the potential to improve the workers' safety. In this perspective, the respiratory rate can provide useful information since it is sensitive to many environmental stressors. In this study, we focused on the development of a test bench to assess the performance of a wearable system for respiratory monitoring. The presented system achieves data collection and synchronization from FBG sensors, a reference flowmeter and, an M-IMU unit. In addition, a GUI has been developed in order to guide the volunteer in the execution of selected movements during the experimental session. The proposed system could further facilitate the design and development of solutions for assessing wearables for workers' activities monitoring.