Cheng-Chun Chang

Dr. Cheng-Chun Chang


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 June 2015 in Sensors
Verified
Journal Article
Open access
PDF file
CCChin-Hsing Chen
Chin-Hsing Chen
WHWen-Tzeng Huang
Wen-Tzeng Huang
Tan-Hsu TanTan-Hsu Tan
Tan-Hsu Tan
CCCheng-Chun Chang
Cheng-Chun Chang
YCYuan-Jen Chang
Yuan-Jen Chang
A reported 30% of people worldwide have abnormal lung sounds, including crackles, rhonchi, and wheezes. To date, the traditional stethoscope remains the most popular tool used by physicians to diagnose such abnormal lung sounds, however, many problems arise with the use of a stethoscope, including the effects of environmental noise, the inability to record and store lung sounds for follow-up or tracking, and the physician’s subjective diagnostic experience. This study has developed a digital stethoscope to help physicians overcome these problems when diagnosing abnormal lung sounds. In this digital system, mel-frequency cepstral coefficients (MFCCs) were used to extract the features of lung sounds, and then the K-means algorithm was used for feature clustering, to reduce the amount of data for computation. Finally, the K-nearest neighbor method was used to classify the lung sounds. The proposed system can also be used for home care: if the percentage of abnormal lung sound frames is > 30% of the whole test signal, the system can automatically warn the user to visit a physician for diagnosis. We also used bend sensors together with an amplification circuit, Bluetooth, and a microcontroller to implement a respiration detector. The respiratory signal extracted by the bend sensors can be transmitted to the computer via Bluetooth to calculate the respiratory cycle, for real-time assessment. If an abnormal status is detected, the device will warn the user automatically. Experimental results indicated that the error in respiratory cycles between measured and actual values was only 6.8%, illustrating the potential of our detector for home care applications.

20 October 2011 in IEEE Sensors Journal
Verified
Journal Article
Closed access
CCCheng-Chun Chang
Cheng-Chun Chang
YSYuan-Jun Su
Yuan-Jun Su
UKUmpei Kurokawa
Umpei Kurokawa
BCByung Il Choi
Byung Il Choi
With the recent development of solid-state lighting (SSL) technologies, visible light communication (VLC) systems using light-emitting diodes (LEDs) has been a promising technology to complement wireless communication. While LEDs offers advantageous properties such as high brightness, lower power consumption, long lifetime, and short transient time for high transmission rates, few researches have been exploited on the receiver side. Conventionally, photoelectric-diodes are implemented to convert optical signals into electronic signals. Since conventional photoelectric-diodes cannot distinguish inputs of different spectra, using conventional photoelectric-diodes have the disadvantage that the system is vulnerable to interference, and that it is hard to achieve wavelength-division-multiplexing (WDM) for light sources of different wavelengths. In this work, a spectrum sensor array is proposed to be implemented on the receiver side to achieve interference rejection. Due to recent advances in semiconductor technologies, spectrum sensors with different spectral transmission properties can be integrated into a chip-scale sensor-array. By proper design of the weightings for individual spectrum sensor, the effective output signal-to-interference ratio (SIR) can be maximized. Following the concept of coherent multi-antenna communication systems, signal fusion algorithms are presented. Our simulation is conducted based on the specification of a prototype filter-array spectrum sensor from nanoLambda. Simulation results demonstrate that robust interference rejection is possible using the low-cost spectrum sensor array.

26 August 2019 in Sensors
Verified
Journal Article
Open access
PDF file
CCCheng-Chun Chang
Cheng-Chun Chang
CWChien-Ta Wu
Chien-Ta Wu
BCByung Il Choi
Byung Il Choi
TFTong-Jing Fang
Tong-Jing Fang
Multi-wavelength photoplethysmography (MW-PPG) sensing technology has been known to be superior to signal-wavelength photoplethysmography (SW-PPG) sensing technology. However, limited by the availability of sensing detectors, many prior studies can only use conventional bulky and pricy spectrometers as the detectors, and hence cannot bring the MW-PPG technology to daily-life applications. In this study we developed a chip-scale MW-PPG sensor using innovative on-chip spectrometers, aimed at wearable applications. Also in this paper we present signal processing methods for robustly extracting the PPG signals, in which an increase of up to 50% in the signal-to-noise ratio (S/N) was observed. Example measurements of saturation of peripheral blood oxygen (SpO2) and blood pressure were conducted.

17 November 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Shao-Hao ChenShao-Hao Chen
Shao-Hao Chen
YCYung-Chi Chuang
Yung-Chi Chuang
CCCheng-Chun Chang
Cheng-Chun Chang
Photoplethysmography (PPG), a noninvasive optical sensing technology, has been widely used to measure various physiological indices. Over-the-counter PPG devices are typically composed of a single-wavelength light source, namely, single-wavelength PPG (SW-PPG). It is known that signals of SW-PPG are easily contaminated or distorted by measurement conditions such as motion artifacts, wearing pressure, and skin type. Since lights of different wavelengths can penetrate skin tissues at different depths, how to effectively construct a multiwavelength PPG (MW-PPG) device or even an all-wavelength PPG (AW-PPG) device has attracted great attention. There is also a very interesting question, that is, what could be the potential benefits of using MW-PPG or AW-PPG devices? This paper demonstrates the construction of an AW-PPG portable device and conducts a preliminary evaluation. The presented device consists of four light-emitting diodes, a chip-scale spectrometer, a microcontroller, a Bluetooth Low Energy transceiver, and a phone app. The maximum ratio combining algorithm (MRC) is used to combine the PPG signals derived from different wavelengths to achieve a better signal-to-noise ratio (S/N). The PPG signals from the developed MRC-AW-PPG device versus those from the conventional SW-PPG device are compared in terms of different hydrostatic pressure conditions. It has been observed that the MRC-AW-PPG device can provide more stable PPG signals than that of a conventional PPG device. The results shine a light on the potential benefits of using multiple wavelengths for the next generation of noninvasive PPG sensing.

17 July 2019 in Water
Verified
Journal Article
Open access
PDF file
YLYung-Bin Lin
Yung-Bin Lin
Tzu Kang LinTzu Kang Lin
Tzu Kang Lin
CCCheng-Chun Chang
Cheng-Chun Chang
CHChang-Wei Huang
Chang-Wei Huang
BCBen-Ting Chen
Ben-Ting Chen
Kuo-Chun ChangKuo-Chun Chang
Kuo-Chun Chang
Offshore wind farms have a superior wind source to terrestrial wind farms, but they also face more severe environmental conditions such as severe storms, typhoons, and sea waves. Scour leads to the excavation of sediments around the foundations of structures, reducing the safe capacity of the structures. The phenomenon of pier scour is extremely complex because of the combined effects of the vortex system involving time-dependent flow patterns and sediment transport mechanisms. A real-time scour monitoring system can improve the safety of structures and afford cost-effective operations by preventing premature or unnecessary maintenance. This paper proposes an on-site scour monitoring system using visible light communication (VLC) modules for offshore wind turbine installations. A flume experiment revealed that the system was highly sensitive and accurate in monitoring seabed scour processes. This arrayed-VLC sensory system, proposed in this paper, has considerable potential for safety monitoring and also can contribute to improving the accuracy of empirical scour formulas for sustainable maintenance in the life cycle of offshore structures.

15 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
LHLing-Cheng Hsu
Ling-Cheng Hsu
SHShiang Hsu
Shiang Hsu
TTTan-Hsu Tan
Tan-Hsu Tan
CCChia-Hsin Cheng
Chia-Hsin Cheng
CCCheng-Chun Chang
Cheng-Chun Chang
In recent years, skin spectral information has been gradually applied in various fields, such as the cosmetics industry and clinical medicine. However, the high price and the huge size of the skin spectrum measurement device make the related applications of the skin spectrum unable to be widely used in practical applications. We used convolutional neural network (CNN) to achieve a satisfying accuracy of the Fitzpatrick skin-type classification by using a simple self-developed device in 2018. Leveraging on the hardware, firmware, and software app-developing experience, a low-cost miniature skin spectrum measurement system (LMSSMS) using deep neural network (DNN) technology was further studied, and the feasibility of the system is verified in this paper. The developed LMSSMS is divided into three parts: (1) miniature skin spectrum measurement device (MSSMD), (2) DNN model, and (3) mobile app. The MSSMD was developed with innovative low-cost MSSC, 3D printing, and a simple LED light source. The DNN model is designed to enhance measurement accuracy. Finally, the mobile app is used to control and show the measurement results. The developed app also includes a variety of skin-spectrum-related applications, such as erythema index and melanin index (EI/MI) measurement, Fitzpatrick skin-type classification, Pantone SkinTone classification, sun-exposure estimation, and body-fat measurement. In order to verify the feasibility of LMSSMS, we used the standard instrumentation device as a reference. The results show that the accuracy of the LMSSMS can reach 94.7%, which also confirms that this development idea has much potential for further development.