Wojciech Grzebieluch

Dr. Wojciech Grzebieluch

Laboratory for Digital Dentistry, Department of Conservative Dentistry witch Endodontics, Wroclaw Medical University, Poland
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 August 2021 in Materials
Verified
Journal Article
Open access
PDF file
WGWojciech Grzebieluch
Wojciech Grzebieluch
Piotr KowalewskiPiotr Kowalewski
Piotr Kowalewski
DGDominika Grygier
Dominika Grygier
Małgorzata RutkowskaMałgorzata Rutkowska
Małgorzata Rutkowska
Marcin KozakiewiczMarcin Kozakiewicz
Marcin Kozakiewicz
Kamil JurczyszynKamil Jurczyszyn
Kamil Jurczyszyn
Thanks to the continuous development of light-curing resin composites it is now possible to print permanent single-tooth restorations. The purpose of this study was to compare resin composites for milling -Gandio Blocks (GR), Brilliant Crios (CR) and Enamic (EN) with resin composite for 3D printing—Varseo Smile Crown plus (VSC). Three-point bending was used to measure flexural strength (σf) and flexural modulus (Ef). The microhardness was measured using a Vickers method, while fractographic, microstructural, texture and fractal dimension (FD) analyses were performed using SEM, optical microscope and picture analysis methods. The values of σf ranged from 118.96 (±2.81) MPa for EN to 186.02 (±10.49) MPa for GR, and the values of Ef ranged from 4.37 (±0.8) GPa for VSC to 28.55 (±0.34) GPa for EN. HV01 ranged from 25.8 (±0.7) for VSC to 273.42 (±27.11) for EN. The filler content ranged from 19–24 vol. % for VSC to 70–80 vol. % for GR and EN. The observed fractures are typical for brittle materials. The correlation between FD of materials microstructure and Ef was observed. σf of the printed resin depends on layers orientation and is significantly lower than σf of GR and CR. Ef of the printed material is significantly lower than Ef of blocks for milling.

28 April 2021 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
WGWojciech Grzebieluch
Wojciech Grzebieluch
MMMarcin Mikulewicz
Marcin Mikulewicz
UKUrszula Kaczmarek
Urszula Kaczmarek
Objective. The aim was to evaluate the flexural strength, flexural modulus, microhardness, Weibull modulus, and characteristic strength of six resin composite blocks (Grandio Blocs-GR, Tetric CAD-TE, Brilliant Crios-CR, Katana Avencia-AV, Cerasmart-CS, and Shofu Block HC-HC). Methods. Flexural strength and flexural modulus were measured using a three-point bending test and microhardness using the Vickers method. Weibull analysis was also performed. Results. The materials showed flexural strength ranging from 120.38 (HC) to 186.02MPa (GR), flexural modulus from 8.26 (HC) to 16.95GPa (GR), and microhardness from 70.85 (AV) to 140.43 (GR). Weibull modulus and characteristic strength ranged from 16.35 (CS) to 34.98 (TE) and from 123.45MPa (HC) to 190.3MPa (GR), respectively. Conclusions. GR, TE, and CR presented significantly higher flexural strength, modulus, Weibull modulus, and characteristic strength than the others.

Verified
Journal Article
Open access
PDF file
AMAndrzej Malysa
Andrzej Malysa
JWJoanna Wezgowiec
Joanna Wezgowiec
WGWojciech Grzebieluch
Wojciech Grzebieluch
DDDariusz Danel
Dariusz Danel
Mieszko WieckiewiczMieszko Wieckiewicz
Mieszko Wieckiewicz
The aim of the study was to evaluate the influence of thermocycling on the shear bond strength of self-adhesive, self-etching resin cements luted to human dentin and computer-aided design/computer-aided manufacturing (CAD/CAM) ceramics. Three modern self-adhesive dental cements (Maxcem Elite, RelyX U200, Panavia SA) were used to lute three CAD/CAM ceramics (IPS Empress CAD, IPS e.max CAD, IPS e.max ZirCAD) onto the dentin. One conventional cement (Panavia V5) served as a control. After preparation, the samples were subjected to thermocycling as a method of artificial aging of dental materials applied to simulate long-term use in oral conditions. Shear bond strength was evaluated according to PN-EN ISO 29022:2013-10 and failure modes were observed under a light microscope. Statistical analysis was performed. The study demonstrated that a combination of ceramics and cements directly impacts the bond strength. The highest bond strength was observed in Panavia V5, lower in Panavia SA and Maxcem Elite and the lowest–in RelyX U200. Adhesive failure between human dentin and cements was the most common failure mode. Moreover, thermocycling highly decreased bond strength of self-adhesive, self-etching cements.

30 June 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MRMartyna Raducka
Martyna Raducka
APAleksandra Piszko
Aleksandra Piszko
Paweł J. PiszkoPaweł J. Piszko
Paweł J. Piszko
NJNatalia Jawor
Natalia Jawor
Maciej DobrzyńskiMaciej Dobrzyński
Maciej Dobrzyński
KSKatarzyna Skośkiewicz-Malinowska
Katarzyna Skośkiewicz-Malinowska
As indicated by standards of modern dentistry, the essence of endodontic treatment is chemo-mechanical disinfection of the root canal system. The vital element of this process is the irrigation of canals with designated solutions as well as activating them. This review article summarizes various techniques of activation of irrigants for endodontic treatment such as manual activation, thermal, pressure, sonic, ultrasonic, and laser techniques in order to compare them. Results were gathered using PubMed, Scopus, Web of Science, and Google Scholar databases by searching keywords: activation, irrigation, irrigation protocols, and sodium hypochlorite.

14 December 2020 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
DKDorota Kustrzycka
Dorota Kustrzycka
TMTim Marschang
Tim Marschang
MMMarcin Mikulewicz
Marcin Mikulewicz
WGWojciech Grzebieluch
Wojciech Grzebieluch
Introduction. The purpose of this systematic review was to compare the accuracy of the three-dimensional images among different scanners, scanning techniques, and substrates. Materials and methods. Electronic databases (PubMed and Elsevier) were searched until March 2020. The systematic search was performed to identify the most precise method of obtaining a 3D image of the dentition. Results. Thirteen articles out of 221, considering the accuracy of 3D images, were selected. The main factors that are considered to have an influence on the precision are substrate type in the oral cavity, experience of the scanners operator, direct vs. indirect scanning, and the reproducibility of the procedure. Conclusion. Substrate type does have an impact on the overall accuracy of intraoral scans where dentin has the most and enamel the least accurately recorded dental structure. Experience of the operator has an influence on the accuracy, where more experienced operators and smaller scan sizes are made for more accurate scans. A conventional impression technique in a full-arch image provided the lowest deviation. The reproducibility of direct scanning was comparable to indirect scanning although a slight difference was noticeable (0.02mm).

27 June 2017 in Advances in Clinical and Experimental Medicine
Verified
Journal Article
Open access
WGWojciech Grzebieluch
Wojciech Grzebieluch
BRBędziński Romuald
Będziński Romuald
CTCzapliński Tomasz
Czapliński Tomasz
UKUrszula Kaczmarek
Urszula Kaczmarek
The FEM is often used in investigations of dentin loading conditions; however, its anisotropy is mostly neglected. The purpose of the study was to evaluate the anisotropy and the elastic properties of an equivalent homogenous material model of human dentin as well as to compare isotropic and anisotropic dentin FE-models. Analytical and numerical dentin homogenization according to Luciano and Barbero was performed and E-modulus (E), Poisson's ratios (v) G-modulus (G) were calculated. The E-modulus of the dentin matrix was 28.0 GPa, Poisson's ratio (v) was 0.3; finite element models of orthotropic and isotropic dentin were created, loaded and compared using Ansys® 14.5 and CodeAster® 11.2 software. Anisotropy of the dentin ranged from 6.9 to 35.2%. E-modulus and G-modulus were as follows: E1 = 22.0-26.0 GPa, E2/E3 = 15.7-23.0 GPa; G12/G13 = 6.96-9.35 GPa and G23 = 6.08-8.09 GPa (highest values in the superficial layer). In FEM analysis of the displacement values were higher in the isotropic than in the orthotropic model, reaching up to 16% by shear load, 37% by compression and 23% in the case of shear with bending. Strain values were higher in the isotropic model, up to 35% for the shear load, 31% for compression and 35% in the case of shear with bending. The decrease in the volumetric fraction and diameter of tubules increased the G and E values. Anisotropy of the dentin applied during FEM analysis decreased the displacements and strain values. The numerical and analytical homogenization of dentin showed similar results.