This paper presents an advanced simulation model of Permanent Magnet Synchronous Motor (PMSM). The vector control scheme of a PMSM drive has been implemented using the developed simulation model. In the developed model, speed and torque as well as the voltages and currents of voltage source inverters components can be effectively monitored and analyzed. The developed simulation model has been implemented using Matlab and the dynamic response of PMSM drive has been analysed for constant speed, varying torque and variable speed constant torque operation. Also, the simulation results have been presented. The simulation results of the developed model has been validated with the circuit simulation using the PMSM block available in the Matlab/Simulink library. Therefore, it can be expected that the developed simulation model can be an easy to design tool for the design and development of PMSM drives for different control algorithms and topological variations with reduced computation time and memory size.
1 November 2017 in IET Science, Measurement & Technology
Electrical shorts in transformers on load can be diagnosed by frequency response analysis (FRA) using impulse or sinusoidal sweep signal. At HV laboratory of SASTRA, a low‐voltage impulse based on‐line on‐load FRA (OLOL FRA) was carried out on a single phase 50 Hz, 1 kVA, 240 V/240 V small laboratory transformer while delivering power to lamp load, and the effectiveness in electrical short diagnosis was analysed. For this purpose, some artificial faults were created within one of the windings of the transformer investigated, and the responses of the winding to different frequency components of the impulse voltages were observed before and after introducing these faults. Comparison of the frequency response (impedance) of the winding under normal condition with frequency response under fault condition was made, which clearly indicated that faults had altered the winding impedance for some frequency components of the impulse. This reveals that fault within the winding can be identified and located, by the OLOL FRA technique, through careful comparisons of frequency response. Statistical analysis of transfer function magnitudes with correlation coefficient, standard deviation and absolute sum of logarithmic error has also validated the same.
Frequency response analysis (FRA) with low impulse voltage signals (IFRA) is useful in diagnosing faults like the mechanical displacements and inter-turn shorts in transformers. However, they fail to diagnose the presence of any source of partial discharges (PD) across the oil-paper insulation. PD is happening only above its inception voltage level for the applied signal, thereby changing the loading effect of the insulation system and becoming detectable. If FRA tests are extended carefully up to high voltages, they can be even useful for the preliminary diagnosis of the potential sources of PD. Investigations were not carried out so far to get an insight into this aspect. Motivated by this, an investigation was done, first time, on a 315 kVA, 11 kV/433 V transformer. IFRA was carried out carefully at various voltage levels, up to 50% of the Basic impulse insulation level. The IFRA results of the transformer under its healthier condition, under the emulated inter-turn shorts and, the PD sources across the major-insulation were, observed and compared. Low-voltage IFRA is found sufficient, only for diagnosing the inter-turn shorts. When IFRA is extended to moderately high voltage, it is found useful in the preliminary diagnosis of the PD sources.
28 November 2014 in The International Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences
In remote sensing applications depth and width of the features in the captured image are necessitate for reclamation estimate and to gather morphological information. This work, aims at demonstrating the potential of stereo pair based anaglyph picture generation by eliminating two cameras carried by Cartosat-I stereo Earth observing satellite. The study is conducted in Trichy Srirangam a part of Tamilnadu. The presented approach involves generating the stereo pair from single cartosat image (Panchromating (PAN), Multispectral (MS)). The depth information is estimated by angular deviation from the stereo pair. The generated anaglyph depth map information can be used in categorizing ravines and depth.
The Frequency Response Analysis approach (FRA) is useful in the fault diagnosis of transformers. However, its usefulness in diagnosing any potential sources of Partial Discharge (PD) in transformers has not been thoroughly investigated so far. In this work, the use of Impulse voltage-based FRA (IFRA) in diagnosing inter-turn shorts and potential sources of PD were investigated on a 315 kVA, 11 kV/433 V transformer. Inter-turn shorts and PD sources were emulated and the usefulness of IFRA in their diagnosis was investigated while using switching impulse voltage at different magnitude levels as the test signals. For emulating the inter-turn shorts and the PDs, special tappings were provided on one of the 11 kV windings through the low capacitance bushings. Low voltage impulse was successful in diagnosing the inter-turn shorts, but unsuccessful in identifying the sources of PDs. During the test condition, the test voltage was adjusted with the presence of artificially created PD sources. The frequency response of the transformer before and after the inception of PD was observed and analyzed in this article. The FRA results demonstrated that the switching impulse voltage based IFRA approach at moderate voltages could be useful in diagnosing the presence of the potential sources of PDs.