Qianhui Wei

Qianhui Wei


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 June 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
JHJiawei Hu
Jiawei Hu
YLYinglu Li
Yinglu Li
XZXufang Zhang
Xufang Zhang
YWYanrong Wang
Yanrong Wang
JZJing Zhang
Jing Zhang
Qingzhu ZhangQingzhu Zhang
Qingzhu Zhang
Acute kidney injury (AKI) is a frequently occurring severe disease with high mortality. Cystatin C (Cys-C), as a biomarker of early kidney failure, can be used to detect and prevent acute renal injury. In this paper, a biosensor based on a silicon nanowire field-effect transistor (SiNW FET) was studied for the quantitative detection of Cys-C. Based on the spacer image transfer (SIT) processes and channel doping optimization for higher sensitivity, a wafer-scale, highly controllable SiNW FET was designed and fabricated with a 13.5 nm SiNW. In order to improve the specificity, Cys-C antibodies were modified on the oxide layer of the SiNW surface by oxygen plasma treatment and silanization. Furthermore, a polydimethylsiloxane (PDMS) microchannel was involved in improving the effectiveness and stability of detection. The experimental results show that the SiNW FET sensors realize the lower limit of detection (LOD) of 0.25 ag/mL and have a good linear correlation in the range of Cys-C concentration from 1 ag/mL to 1 pg/mL, exhibiting its great potential in the future real-time application.

24 May 2024 in Nanomaterials
Verified
Journal Article
Open access
PDF file
WGWeiqing Guo
Weiqing Guo
QWQianhui Wei
Qianhui Wei
GLGangrong Li
Gangrong Li
FWFeng Wei
Feng Wei
Zhuofeng HuZhuofeng Hu
Zhuofeng Hu
Creating oxygen vacancy in tungsten trioxide (WO3) has been considered as an effective strategy to improve the photocatalytic performance for degrading organic pollutants. In this study, oxygen vacancies were introduced into WO3 by thermal treatment under Ar atmosphere and their proportion was changed by setting different treatment times. WO3−x samples show better photoelectric properties and photocatalytic degradation performance for carbamazepine (CBZ) than an oxygen-vacancy-free sample, and WO3−x with the optimal proportion of oxygen vacancies is obtained by thermal treatment for 3 h in 550 °C. Furthermore, it discovers that the surface oxygen vacancies on WO3−x would be recovered when it is exposed to air, resulting in a bulk oxygen vacancy dominating WO3−x (bulk-WO3−x). The bulk-WO3−x exhibited much higher degradation efficiency for CBZ than WO3−x with both surface and bulk oxygen vacancies. The mechanism study shows bulk-WO3−x mainly degrades the CBZ by producing OH radicals and superoxide radicals, while oxygen-vacancy-free sample mainly oxidizes the CBZ by the photoexcited hole, which requires the CBZ to be adsorbed on the surface for degradation. The radical generated by bulk-WO3−x exhibits stronger oxidizing capacity by migrating to the solution for CBZ degradation. In summary, the influence of oxygen vacancy on photocatalytic degradation performance depends on both the proportion and location distribution and could lie in the optimization of the photodegradation mechanism. The results of this study could potentially broaden our understanding of the role of oxygen vacancies and provide optimal directions and methods for oxygen vacancy regulation for photocatalysts.

11 December 2020 in Nanomaterials
Verified
Journal Article
Open access
PDF file
STSiqi Tang
Siqi Tang
JYJiang Yan
Jiang Yan
JZJing Zhang
Jing Zhang
SWShuhua Wei
Shuhua Wei
Qingzhu ZhangQingzhu Zhang
Qingzhu Zhang
HTHailing Tu
Hailing Tu
In this paper, the poly-Si nanowire (NW) field-effect transistor (FET) sensor arrays were fabricated by adopting low-temperature annealing (600 °C/30 s) and feasible spacer image transfer (SIT) processes for future monolithic three-dimensional integrated circuits (3D-ICs) applications. Compared with other fabrication methods of poly-Si NW sensors, the SIT process exhibits the characteristics of highly uniform poly-Si NW arrays with well-controlled morphology (about 25 nm in width and 35 nm in length). Conventional metal silicide and implantation techniques were introduced to reduce the parasitic resistance of source and drain (SD) and improve the conductivity. Therefore, the obtained sensors exhibit >106 switching ratios and 965 mV/dec subthreshold swing (SS), which exhibits similar results compared with that of SOI Si NW sensors. However, the poly-Si NW FET sensors show the Vth shift as high as about 178 ± 1 mV/pH, which is five times larger than that of the SOI Si NW sensors. The fabricated poly-Si NW sensors with 600 °C/30 s processing temperature and good device performance provide feasibility for future monolithic three-dimensional integrated circuit (3D-IC) applications.

26 December 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
KMKuo Men
Kuo Men
ZLZiwei Lian
Ziwei Lian
HTHailing Tu
Hailing Tu
HZHongbin Zhao
Hongbin Zhao
QWQianhui Wei
Qianhui Wei
FWFeng Wei
Feng Wei
In this paper, we report an all-dielectric metamaterial terahertz biosensor, which exhibits a high Q factor of 35 at an 0.82 resonance peak. A structure with an electromagnetically induced transparency effect was designed and fabricated to perform a Mie resonance for the terahertz response. The biosensor exhibits a limit of detection of 100 pg/mL for cytokine interleukin 2 (IL-2) and a linear response for the logarithm of the concentration of IL-2 in the range of 100 pg/mL to 1 μg/mL. This study implicates an important potential for the detection of cytokines in serum and has potential application in the clinical detection of cytokine release syndrome.

2 February 2023 in Nanomaterials
Verified
Journal Article
Open access
PDF file
YZYan Zhu
Yan Zhu
QWQianhui Wei
Qianhui Wei
QJQingxi Jin
Qingxi Jin
GLGangrong Li
Gangrong Li
Qingzhu ZhangQingzhu Zhang
Qingzhu Zhang
YLYingchun Luo
Yingchun Luo
Accurate monitoring of blood glucose levels is crucial for the diagnosis of diabetes patients. In this paper, we proposed a simple “mixed-catalyzer layer” modified silicon nanowire field-effect transistor biosensor that enabled direct detection of glucose with low-charge in high ionic strength solutions. A stable screening system was established to overcome Debye screening effect by forming a porous biopolymer layer with polyethylene glycol (PEG) modified on the surface of SiNW. The experimental results show that when the optimal ratio (APTMS:silane-PEG = 2:1) modified the surface of silicon nanowires, glucose oxidase can detect glucose in the concentration range of 10 nM to 10 mM. The sensitivity of the biosensor is calculated to be 0.47 μAcm−2mM−1, its fast response time not exceeding 8 s, and the detection limit is up to 10 nM. This glucose sensor has the advantages of high sensitivity, strong specificity and fast real-time response. Therefore, it has a potential clinical application prospect in disease diagnosis.

16 June 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
GLGangrong Li
Gangrong Li
QWQianhui Wei
Qianhui Wei
SWShuhua Wei
Shuhua Wei
JZJing Zhang
Jing Zhang
QJQingxi Jin
Qingxi Jin
HTHailing Tu
Hailing Tu
In this study, we report a pH-responsive hydrogel-modified silicon nanowire field-effect transistor for pH sensing, whose modification is operated by spin coating, and whose performance is characterized by the electrical curve of field-effect transistors. The results show that the hydrogel sensor can measure buffer pH in a repeatable and stable manner in the pH range of 3–13, with a high pH sensitivity of 100 mV/pH. It is considered that the swelling of hydrogel occurring in an aqueous solution varies the dielectric properties of acrylamide hydrogels, causing the abrupt increase in the source-drain current. It is believed that the design of the sensor can provide a promising direction for future biosensing applications utilizing the excellent biocompatibility of hydrogels.