Jiawei Hu

Mr. Jiawei Hu


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 June 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
JHJiawei Hu
Jiawei Hu
YLYinglu Li
Yinglu Li
XZXufang Zhang
Xufang Zhang
YWYanrong Wang
Yanrong Wang
JZJing Zhang
Jing Zhang
Qingzhu ZhangQingzhu Zhang
Qingzhu Zhang
Acute kidney injury (AKI) is a frequently occurring severe disease with high mortality. Cystatin C (Cys-C), as a biomarker of early kidney failure, can be used to detect and prevent acute renal injury. In this paper, a biosensor based on a silicon nanowire field-effect transistor (SiNW FET) was studied for the quantitative detection of Cys-C. Based on the spacer image transfer (SIT) processes and channel doping optimization for higher sensitivity, a wafer-scale, highly controllable SiNW FET was designed and fabricated with a 13.5 nm SiNW. In order to improve the specificity, Cys-C antibodies were modified on the oxide layer of the SiNW surface by oxygen plasma treatment and silanization. Furthermore, a polydimethylsiloxane (PDMS) microchannel was involved in improving the effectiveness and stability of detection. The experimental results show that the SiNW FET sensors realize the lower limit of detection (LOD) of 0.25 ag/mL and have a good linear correlation in the range of Cys-C concentration from 1 ag/mL to 1 pg/mL, exhibiting its great potential in the future real-time application.

16 June 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
GLGangrong Li
Gangrong Li
QWQianhui Wei
Qianhui Wei
SWShuhua Wei
Shuhua Wei
JZJing Zhang
Jing Zhang
QJQingxi Jin
Qingxi Jin
HTHailing Tu
Hailing Tu
In this study, we report a pH-responsive hydrogel-modified silicon nanowire field-effect transistor for pH sensing, whose modification is operated by spin coating, and whose performance is characterized by the electrical curve of field-effect transistors. The results show that the hydrogel sensor can measure buffer pH in a repeatable and stable manner in the pH range of 3–13, with a high pH sensitivity of 100 mV/pH. It is considered that the swelling of hydrogel occurring in an aqueous solution varies the dielectric properties of acrylamide hydrogels, causing the abrupt increase in the source-drain current. It is believed that the design of the sensor can provide a promising direction for future biosensing applications utilizing the excellent biocompatibility of hydrogels.