Erik Fröjdh

Dr. Erik Fröjdh

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 March 2024 in Advanced Materials
Verified
Journal Article
Open access
TBTim A. Butcher
Tim A. Butcher
NPNicholas W. Phillips
Nicholas W. Phillips
CCChun‐Chien Chiu
Chun‐Chien Chiu
CWChia‐Chun Wei
Chia‐Chun Wei
SHSheng‐Zhu Ho
Sheng‐Zhu Ho
JRJörg Raabe
Jörg Raabe
Understanding the magnetic and ferroelectric ordering of magnetoelectric multiferroic materials at the nanoscale necessitates a versatile imaging method with high spatial resolution. Here, soft X‐ray ptychography is employed to simultaneously image the ferroelectric and antiferromagnetic domains in an 80 nm thin freestanding film of the room‐temperature multiferroic BiFeO3 (BFO). The antiferromagnetic spin cycloid of period 64 nm is resolved by reconstructing the corresponding resonant elastic X‐ray scattering in real space and visualized together with mosaic‐like ferroelectric domains in a linear dichroic contrast image at the Fe L3 edge. The measurements reveal a near perfect coupling between the antiferromagnetic and ferroelectric ordering by which the propagation direction of the spin cycloid is locked orthogonally to the ferroelectric polarization. In addition, the study evinces both a preference for in‐plane propagation of the spin cycloid and changes of the ferroelectric polarization by 71° between multiferroic domains in the epitaxial strain‐free, freestanding BFO film. The results provide a direct visualization of the strong magnetoelectric coupling in BFO and of its fine multiferroic domain structure, emphasizing the potential of ptychographic imaging for the study of multiferroics and non‐collinear magnetic materials with soft X‐rays.

23 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
DGDominic Greiffenberg
Dominic Greiffenberg
MAMarie Andrä
Marie Andrä
RBRebecca Barten
Rebecca Barten
ABAnna Bergamaschi
Anna Bergamaschi
MBMartin Brückner
Martin Brückner
JZJiaguo Zhang
Jiaguo Zhang
Chromium compensated GaAs or GaAs:Cr sensors provided by the Tomsk State University (Russia) were characterized using the low noise, charge integrating readout chip JUNGFRAU with a pixel pitch of 75 × 75 µm2 regarding its application as an X-ray detector at synchrotrons sources or FELs. Sensor properties such as dark current, resistivity, noise performance, spectral resolution capability and charge transport properties were measured and compared with results from a previous batch of GaAs:Cr sensors which were produced from wafers obtained from a different supplier. The properties of the sample from the later batch of sensors from 2017 show a resistivity of 1.69 × 109 Ω/cm, which is 47% higher compared to the previous batch from 2016. Moreover, its noise performance is 14% lower with a value of (101.65 ± 0.04) e− ENC and the resolution of a monochromatic 60 keV photo peak is significantly improved by 38% to a FWHM of 4.3%. Likely, this is due to improvements in charge collection, lower noise, and more homogeneous effective pixel size. In a previous work, a hole lifetime of 1.4 ns for GaAs:Cr sensors was determined for the sensors of the 2016 sensor batch, explaining the so-called “crater effect” which describes the occurrence of negative signals in the pixels around a pixel with a photon hit due to the missing hole contribution to the overall signal causing an incomplete signal induction. In this publication, the “crater effect” is further elaborated by measuring GaAs:Cr sensors using the sensors from 2017. The hole lifetime of these sensors was 2.5 ns. A focused photon beam was used to illuminate well defined positions along the pixels in order to corroborate the findings from the previous work and to further characterize the consequences of the “crater effect” on the detector operation.

9 August 2017 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
Gemma TintiGemma Tinti
Gemma Tinti
HMH. Marchetto
H. Marchetto
CVC. A. F. Vaz
C. A. F. Vaz
AKArmin Kleibert
Armin Kleibert
MAM. Andrä
M. Andrä
JZJ. Zhang
J. Zhang
EIGER is a single-photon-counting hybrid pixel detector developed at the Paul Scherrer Institut, Switzerland. It is designed for applications at synchrotron light sources with photon energies above 5 keV. Features of EIGER include a small pixel size (75 µm × 75 µm), a high frame rate (up to 23 kHz), a small dead-time between frames (down to 3 µs) and a dynamic range up to 32-bit. In this article, the use of EIGER as a detector for electrons in low-energy electron microscopy (LEEM) and photoemission electron microscopy (PEEM) is reported. It is demonstrated that, with only a minimal modification to the sensitive part of the detector, EIGER is able to detect electrons emitted or reflected by the sample and accelerated to 8–20 keV. The imaging capabilities are shown to be superior to the standard microchannel plate detector for these types of applications. This is due to the much higher signal-to-noise ratio, better homogeneity and improved dynamic range. In addition, the operation of the EIGER detector is not affected by radiation damage from electrons in the present energy range and guarantees more stable performance over time. To benchmark the detector capabilities, LEEM experiments are performed on selected surfaces and the magnetic and electronic properties of individual iron nanoparticles with sizes ranging from 8 to 22 nm are detected using the PEEM endstation at the Surface/Interface Microscopy (SIM) beamline of the Swiss Light Source.

5 February 2024 in Frontiers in Physics
Verified
Journal Article
Open access
EFErik Fröjdh
Erik Fröjdh
ABAnna Bergamaschi
Anna Bergamaschi
BSBernd Schmitt
Bernd Schmitt
When first introduced, single-photon counting detectors reshaped crystallography at synchrotrons. Their fast readout speed enabled, for example, shutter-less data collection and fine slicing of the rotation angle and boosted the development of new experimental techniques like ptychography. Under optimal conditions, single-photon counting detectors provide an unlimited dynamic range with image noise only limited by the Poisson statistics of the incoming photons. Counting the pulses from individual photons, essentially what made the detectors so successful, also causes the main drawback, which is the loss of efficiency at high photon fluxes due to pulse pileup in the analog front end. To fully take advantage of diffraction-limited light sources, the next-generation single-photon counters need to improve their count rate capabilities in the same order of magnitude as the increased flux. Moreover, fast frame rates (a few kHz) are required to cope with the shorter dwell time achievable, thanks to the higher flux. Detector architecture with multiple comparators and counters can open new possibilities for energy-resolved imaging, while interpixel communication can overcome the issues arising from charge sharing and reduce the loss of efficiency at the pixel corners. Coupling single-photon counting detectors to high-Z sensors for hard X-ray detection (>20 keV) and to low-gain avalanche diodes (LGADs) for soft X-rays is also necessary to make use of the increased coherence of the new light sources over the full radiation spectrum. In this paper, we present possible strategies to improve the performance of single-photon counting detectors at the fourth-generation synchrotron sources and compare them to charge integrating detectors.

17 December 2020 in Crystals
Verified
Journal Article
Open access
PDF file
EFErik Fröjdh
Erik Fröjdh
JWJulian T. C. Wennmacher
Julian T. C. Wennmacher
PRPrzemyslaw Rzepka
Przemyslaw Rzepka
AMAldo Mozzanica
Aldo Mozzanica
SRSophie Redford
Sophie Redford
TGTim Gruene
Tim Gruene
The crystal structure of a chemical compound serves several purposes: its coordinates represent three-dimensional information about the connectivity between the atoms; it is the only technique that determines the absolute configuration of chiral molecules; it enables determining structure–function relations; and crystallographic data at atomic resolution distinguish between element types and serve as a confirmation of synthesis protocols. Here, we collected electron diffraction data from albite and from a Linde Type A (LTA) type zeolite. Both compounds are aluminosilicates with well-defined silicon and aluminum crystallographic sites. Data were recorded with the “adJUstiNg Gain detector FoR the Aramis User station” (JUNGFRAU detector) and we made use of its capability of energy discrimination to suppress noise. For both compounds, crystallographic refinement distinguishes correctly between silicon and aluminum, even though these elements have very similar electron scattering factors. These results highlight the quality of the electron diffraction data and the reliability of the models for chemical interpretation. Further development in this direction will provide enormous opportunities for structure–function studies by diffraction.

31 January 2024 in Sensors
Verified
Journal Article
Open access
PDF file
MAMaria del mar Carulla Areste
Maria del mar Carulla Areste
RBRebecca Barten
Rebecca Barten
FBFilippo Baruffaldi
Filippo Baruffaldi
ABAnna Bergamaschi
Anna Bergamaschi
GBGiacomo Borghi
Giacomo Borghi
JZJiaguo Zhang
Jiaguo Zhang
Hybrid pixel detectors have become indispensable at synchrotron and X-ray free-electron laser facilities thanks to their large dynamic range, high frame rate, low noise, and large area. However, at energies below 3 keV, the detector performance is often limited because of the poor quantum efficiency of the sensor and the difficulty in achieving single-photon resolution due to the low signal-to-noise ratio. In this paper, we address the quantum efficiency of silicon sensors by refining the design of the entrance window, mainly by passivating the silicon surface and optimizing the dopant profile of the n+ region. We present the measurement of the quantum efficiency in the soft X-ray energy range for silicon sensors with several process variations in the fabrication of planar sensors with thin entrance windows. The quantum efficiency for 250 eV photons is increased from almost 0.5% for a standard sensor to up to 62% as a consequence of these developments, comparable to the quantum efficiency of backside-illuminated scientific CMOS sensors. Finally, we discuss the influence of the various process parameters on quantum efficiency and present a strategy for further improvement.