Tobias Hutzenlaub

Dr. Tobias Hutzenlaub


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2021 in Processes
Verified
Journal Article
Open access
PDF file
FSFranziska Schlenker
Franziska Schlenker
EKElena Kipf
Elena Kipf
NBNadine Borst
Nadine Borst
NPNils Paust
Nils Paust
RZRoland Zengerle
Roland Zengerle
THTobias Hutzenlaub
Tobias Hutzenlaub
We present the centrifugal microfluidic implementation of a four-plex digital droplet polymerase chain reaction (ddPCR). The platform features 12 identical ddPCR units on a LabDisk cartridge, each capable of generating droplets with a diameter of 82.7 ± 9 µm. By investigating different oil–surfactant concentrations, we identified a robust process for droplet generation and stabilization. We observed high droplet stability during thermocycling and endpoint fluorescence imaging, as is required for ddPCRs. Furthermore, we introduce an automated process for four-color fluorescence imaging using a commercial cell analysis microscope, including a customized software pipeline for ddPCR image evaluation. The applicability of ddPCRs is demonstrated by the quantification of three cancer-associated KRAS point mutations (G12D, G12V and G12A) in a diagnostically relevant wild type DNA background. The four-plex assay showed high sensitivity (3.5–35 mutant DNA copies in 15,000 wild type DNA copies) and linear performance (R² = 0.99) across all targets in the LabDisk.

6 September 2021 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
DKDaniel M. Kainz
Daniel M. Kainz
BBBastian J. Breiner
Bastian J. Breiner
SFSusanna M. Früh
Susanna M. Früh
THTobias Hutzenlaub
Tobias Hutzenlaub
RZRoland Zengerle
Roland Zengerle
NPNils Paust
Nils Paust
Despite the widespread application of point-of-care lateral flow tests, the viscosity dependence of these assay results remains a significant challenge. Here, we employ centrifugal microfluidic flow control through the nitrocellulose membrane of the strip to eliminate the viscosity bias. The key feature is the balancing of the sample flow into the cassette of the lateral flow test with the air flow out of the cassette. A viscosity-independent flow rate of 3.01 ± 0.18 µl/min (±6%) is demonstrated for samples with viscosities ranging from 1.1 mPas to 24 mPas, a factor greater than 20. In a model human IgG lateral flow assay, signal-intensity shifts caused by varying the sample viscosity from 1.1 mPas to 2.3 mPas could be reduced by more than 84%.

26 January 2023 in The Analyst
Verified
Journal Article
Closed access
PDF file
FSFranziska Schlenker
Franziska Schlenker
PJPeter Juelg
Peter Juelg
JLJan Lüddecke
Jan Lüddecke
NPNils Paust
Nils Paust
RZRoland Zengerle
Roland Zengerle
THTobias Hutzenlaub
Tobias Hutzenlaub
A new concept for an automated cfDNA extraction with nanobeads as the solid phase in a centrifugal microfluidic LabDisk. Nanobeads are retained in one incubation chamber while the sample and pre-stored buffers are sequentially added and removed.

16 November 2021 in Cancers
Verified
Journal Article
Open access
PDF file
FSFranziska Schlenker
Franziska Schlenker
EKElena Kipf
Elena Kipf
MDMax Deuter
Max Deuter
IHInga Höffkes
Inga Höffkes
MLMichael Lehnert
Michael Lehnert
NBNadine Borst
Nadine Borst
There is an increasing demand for optimization-free multiplex assays to rapidly establish comprehensive target panels for cancer monitoring by liquid biopsy. We present the mediator probe (MP) PCR for the quantification of the seven most frequent point mutations and corresponding wild types (KRAS and BRAF) in colorectal carcinoma. Standardized parameters for the digital assay were derived using design of experiments. Without further optimization, the limit of detection (LoD) was determined through spiking experiments with synthetic mutant DNA in human genomic DNA. The limit of blank (LoB) was measured in cfDNA plasma eluates from healthy volunteers. The 2-plex and 4-plex MP ddPCR assays showed a LoB of 0 copies/mL except for 4-plex KRAS G13D (9.82 copies/mL) and 4-plex BRAF V600E (16.29 copies/mL) and allele frequencies of 0.004% ≤ LoD ≤ 0.38% with R2 ≥ 0.98. The quantification of point mutations in patient plasma eluates (18 patients) during follow-up using the 4-plex MP ddPCR showed a comparable performance to the reference assays. The presented multiplex assays need no laborious optimization, as they use the same concentrations and cycling conditions for all targets. This facilitates assay certification, allows a fast and flexible design process, and is thus easily adaptable for individual patient monitoring.

5 February 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
LBLisa Becherer
Lisa Becherer
JHJacob Friedrich Hess
Jacob Friedrich Hess
SFSieghard Frischmann
Sieghard Frischmann
MBMohammed Bakheit
Mohammed Bakheit
HNHans Nitschko
Hans Nitschko
FSFelix von Stetten
Felix von Stetten
This paper presents a universal point-of-care system for fully automated quantification of human T-cell lymphotropic virus type 1 (HTLV-1) proviral load, including genomic RNA, based on digital reverse RNA transcription and c-DNA amplification by MD LAMP (mediator displacement loop-mediated isothermal amplification). A disposable microfluidic LabDisk with pre-stored reagents performs automated nucleic acid extraction, reaction setup, emulsification, reverse transcription, digital DNA amplification, and quantitative fluorogenic endpoint detection with universal reporter molecules. Automated nucleic acid extraction from a suspension of HTLV-1-infected CD4+ T-lymphocytes (MT-2 cells) yielded 8 ± 7 viral nucleic acid copies per MT-2 cell, very similar to the manual reference extraction (7 ± 2 nucleic acid copies). Fully automated sample processing from whole blood spiked with MT-2 cells showed a comparable result of 7 ± 3 copies per MT-2 cell after a run time of two hours and 10 min.

Verified
Journal Article
Open access
PDF file
MNMaximilian Neugebauer
Maximilian Neugebauer
SCSilvia Calabrese
Silvia Calabrese
SMSarah Müller
Sarah Müller
TTTruong-Tu Truong
Truong-Tu Truong
PJPeter Juelg
Peter Juelg
MLMichael Lehnert
Michael Lehnert
Digital PCR (dPCR) is a powerful method for highly sensitive and precise quantification of nucleic acids. However, designing and optimizing new multiplex dPCR assays using target sequence specific probes remains cumbersome, since fluorescent signals must be optimized for every new target panel. As a solution, we established a generic fluorogenic 6-plex reporter set, based on mediator probe technology, that decouples target detection from signal generation. This generic reporter set is compatible with different target panels and thus provides already optimized fluorescence signals from the start of new assay development. Generic reporters showed high population separability in a colorimetric 6-plex mediator probe dPCR, due to their tailored fluorophore and quencher selection. These reporters were further tested using different KRAS, NRAS and BRAF single-nucleotide polymorphisms (SNP), which are frequent point mutation targets in liquid biopsy. We specifically quantified SNP targets in our multiplex approach down to 0.4 copies per microliter (cp/µL) reaction mix, equaling 10 copies per reaction, on a wild-type background of 400 cp/µL for each, equaling 0.1% variant allele frequencies. We also demonstrated the design of an alternative generic reporter set from scratch in order to give detailed step-by-step guidance on how to systematically establish and optimize novel generic reporter sets. Those generic reporter sets can be customized for various digital PCR platforms or target panels with different degrees of multiplexing.