A ceiling cooling system integrated with a mechanical ventilation system has been widely used in modern buildings with large sensible cooling loads due to the high thermal comfort level and large energy efficiency. However, there is a lack of systematic research on the influence factors such as ceiling surface temperature and cooling load on the indoor air distribution and thermal environment, and the impact of ventilation system type in the ceiling cooling room is still unclear. Therefore, this paper presented an experimental study of indoor air distribution and thermal environment in a ceiling cooling (CC) room with mixing ventilation (MV), underfloor air distribution (UFAD) and stratum ventilation (SV); the ceiling surface temperature was 17 °C–26 °C and the internal or external cooling load was 41.5 W/m2–69.5 W/m2. The results showed that the vertical air temperature difference and contaminant removal effectiveness were 0.2 °C–0.4 °C and 0.53–0.85 with CC + MV, 0 °C–1.2 °C and 0.68–1.25 with CC + UFAD and 0.3 °C–0.9 °C and 0.50–0.83 with CC + SV, and the corresponding heat removal effectiveness and air diffusion performance index were 0.96–1.11 and 96–100%, 0.9–1.5 and 57–100% and 1.11–1.34 and 71–100%, respectively. Moreover, the difference between mean radiant temperature and air temperature and the predicted mean vote of thermal sensation were from 0 °C to 0.9 °C and between 0 and 0.26 with CC + MV, from −0.1 °C to 2.2 °C and between −0.1 and 0.42 with CC + UFAD and from −0.1 °C to 0.9 °C and between −0.2 and 0.13 with CC + SV. Hence, the ventilation system type clearly affected the indoor air distribution and thermal environment in the ceiling cooling room, and the experimental results would be beneficial for the design and control of a ceiling cooling system combined with a mechanical ventilation system in practice.
The radiant ceiling cooling system is widely adopted in modern office buildings as it improves cooling source efficiency and reduces fossil fuel usage and carbon dioxide emissions by utilizing low-grade natural energy. However, the nonlinear behavior and significant inertia of the radiant ceiling cooling system pose challenges for control systems. With advancements in computer technology and artificial intelligence, the deep reinforcement learning (DRL) method shows promise in the operation and control of radiant cooling systems with large inertia. This paper compares the DRL control method with traditional control methods for radiant ceiling cooling systems in two typical office rooms across three different regions. Simulation results demonstrate that with an indoor target temperature of 26 °C and an allowable fluctuation range of ±1 °C, the DRL on–off or varied water temperature control satisfies the indoor temperature fluctuation requirements for 80% or 93–99% of the operating time, respectively. In contrast, the traditional on–off or PID variable water temperature control only meets these requirements for approximately 70% or 90–93% of the operating time. Furthermore, compared to traditional on–off control, the DRL control can save energy consumption in the radiant ceiling cooling system by 3.19% to 6.30%, and up to 10.48% compared to PID variable water temperature control. Consequently, the DRL control method exhibits superior performance in terms of minimizing indoor temperature fluctuations and reducing energy consumption in radiant ceiling cooling systems.
A radiant ceiling cooling (CC) system integrated with a mechanical ventilation system was extensively applied in a modern office in a glass curtain wall building. Thermal comfort in a radiant ceiling cooling room with mixing ventilation (MV) or underfloor air distribution (UFAD) was investigated by objective measurements and subjective questionnaires. The external wall surface temperature and mean radiant temperature were 33.9–34.6°C and 27.2–27.4°C, respectively, with a heat transfer of 41.5 W/m2 from the external wall and 37.8–38.6°C and 27.4–28.2°C with a heat transfer of 69.5 W/m2 from the external wall. The indoor air velocity in the occupied zone was 0.17–0.23 m/s in the room with CC+MV and 0.09–0.16 m/s in the room with CC + UFAD. There was a considerable difference between occupants’ thermal perceptions with different distances away from the external wall. Both the ventilation system type and hot wall surface temperature did not influence occupants’ overall thermal perceptions, but their local thermal sensation and skin temperature. The results suggest that the impacts of ventilation system type and hot wall surface temperature on occupants’ local thermal response should be considered during the design of a radiant ceiling cooling system combined with a mechanical ventilation system.
A ceiling cooling (CC) system integrated with a mechanical ventilation system is an advanced HVAC system for the modern office building with glass curtain wall. In this paper, considering the influence of heat transfer of external envelope, the indoor thermal environment and human thermal comfort were objectively measured and subjectively evaluated in a ceiling cooling room with mixing ventilation (MV) or underfloor air distribution (UFAD). Indoor physical parameters and human skin temperatures were measured as the chilled ceiling surface temperature and supply air temperature were 17.1°C-17.6°C and 22.2°C - 22.6°C. Simultaneously, 16 subjects (8 males and 8 females) were selected to subjectively evaluate the thermal environment. The results showed that the difference between mean radiant temperature and air temperature in the occupied zone was 0.8°C with CC+MV and 1.2°C with CC+UFAD, and the indoor air velocity was 0.17m/s with CC+MV and 0.13m/s with CC+UFAD. In addition, the calculated and measured thermal sensation votes with CC+MV were all slightly less than those with CC+UFAD. Therefore, ventilation system type had a slight impact on the indoor thermal environment and human thermal comfort in the ceiling cooling room.
Indoor wet-bulb globe temperature (WBGT) was extensively used to evaluate the indoor hot environment in a naturally ventilated building, but it does not consider the effect of air movement caused by the hot surface. A potential evaluation index, which is a difference between the mean radiant temperature and the air temperature (Δtr–a), was introduced to be integrated with the indoor WBGT to evaluate the indoor hot environment with hot surface. Subjective evaluation of the occupant's thermal perceptions and objective measurement of indoor physical parameters were carried out in a typical naturally ventilated room with hot surface ranged from 50°C to 250°C. The results show that the indoor air temperature, mean radiant temperature and WBGT were increased by 8.6°C–12.9°C, 11.2°C–29.7°C and 4.7°C–7.5°C, respectively, with participant's light activity, and by 9.9°C–13.5°C, 14.9°C–29.4°C and 5.7°C–8.0°C, respectively, with participant's heavy activity. Indoor air temperature was increased linearly with the indoor WBGT, whereas the mean radiant temperature was increased non-linearly with the indoor WBGT. Besides, the non-linear relationship between the occupant's thermal perceptions and Δtr−a coincided very well with those between occupant's thermal perceptions and indoor WBGT. This suggests that the Δtr–a may be a potential index to be integrated with the indoor WBGT for evaluating the indoor hot environment in naturally ventilated building with hot surface.