The purpose of this systematic review was to investigate the clinical outcomes of frameworks made of different materials in patients with implant-supported full-arch prostheses. A literature search was conducted on MEDLINE, Scopus and Cochrane Library, until the 1st of March 2021, with the following search terms: framework or substructure combined with “dental implants”. The outcomes evaluated were: implant and prosthesis survival, bone resorption, biological and technical complications. The Cochrane Handbook for Systematic Reviews of Interventions was employed to assess the risk of bias in randomized clinical trials. The Newcastle–Ottawa quality assessment scale was used for non-randomized studies. In total, 924 records were evaluated for title and abstract, and 11 studies were included in the review: 4 clinical randomized trials and 7 cohort studies. The framework materials investigated were: gold alloy, titanium, silver-palladium alloy, zirconia and polymers including acrylic resin and carbon-fiber-reinforced composites. High implant and prosthetic cumulative survival rates were recorded by all included studies. Various materials and different fabrication techniques are now available as alternatives to traditional cast metal frameworks, for full-arch implant-supported rehabilitations. Further long-term studies are needed to validate the use of these materials and clarify their specific clinical indications and manufacturing protocols to optimize their clinical outcomes.
Oral squamous cell carcinoma (OSCC) is a widespread malignancy with high mortality. In particular, a delay in its diagnosis dramatically decreases the survival rate. The aim of this systematic review was to investigate and summarize clinical results in the literature, regarding the potential use of salivary microRNAs (miRNAs) as diagnostic and prognostic biomarkers for OSCC patients. Twelve papers were selected, including both case–control and cohort studies, and all of them detected significantly dysregulated miRNAs in OSCC patients compared to healthy controls. Based on our results, salivary miRNAs might provide a non-invasive and cost-effective method in the diagnosis of OSCC, and also to monitor more easily its evolution and therapeutic response and therefore aid in the establishment of specific therapeutic strategies.
Recently, tissue-level implants with a convergent collar have been introduced. While different studies have investigated the outcomes of this implant design in the rehabilitation of single teeth, its use in full-arch rehabilitation has yet to be investigated. The present case report describes the clinical outcomes of a full-arch immediate loading rehabilitation using tissue-level implants, with and without using implant-abutment units, with 2 years of follow-up. A female patient with mandibular terminal dentition and a high level of bone resorption (distal areas with a few millimeters of residual bone in the vertical dimension and both distal and anterior areas with narrow crestal bone in the horizontal dimension) was seen at the C.I.R Dental School, Turin, Italy. The patient was seeking to be rehabilitated with fixed prosthodontics, and she was found eligible for an immediate loading implant full-arch rehabilitation. Four implants were inserted in the same appointment. The two anterior implants were inserted straight and connected directly to the prosthesis (no abutments); the two distal implants were tilted in order to avoid the alveolar nerve and connected to two 30° angulated abutments. Two years post-implant placement, all of the implants were successfully integrated, resulting in an implant survival rate of 100%. The peri-implant soft tissues were stable at all the implant sites. No differences were highlighted between those implants with and without abutments. Within the limitations of the present clinical report, implant full-arch rehabilitations with tissue-level implants both with and without implant-abutment units showed optimal outcomes after two years of follow-up. Further research is encouraged to confirm whether this implant design may be a valid alternative to traditional implants in this type of rehabilitation, with or without implant-abutment units.
(1) Background: Intraoral scanners (IOS) are widely used in prosthodontics. However, a good trueness is mandatory to achieve optimal clinical results. The aim of the present in vitro study was to compare two IOS considering the operator’s experience and different implant clinical scenarios. (2) Methods: Two IOS (IT—Itero, Align Technology; and OP—Opera MC, Opera System, Monaco) were compared simulating three different clinical scenarios: single implant, two implants, and full-arch rehabilitation. Ten scans were taken for each configuration by two different operators (one expert, one inexperienced); influence of operator experience and the type of scanner used was investigated. (3) Results: Trueness of the scans differed between the experienced and non-experienced operator and this difference was statistically significant in all the three scenarios (p = 0.000–0.001, 0.037). A significant difference was present between the scanners (p = 0.000), in the two-implant and full-arch scenarios (p = 0.00). (4) Conclusions: Experience of the operator significantly affect trueness of IT and OP scanners. A statistically significant difference was present among IOS in the two-implant and full-arch scenarios.
Background: The aim of the present study was to investigate the accuracy of a new digital impression system, comparing it to the plaster impression technique in the realization of full-arch implant-supported metal frameworks. Methods: We took 11 scans (8 of the upper maxilla and 3 of the lower jaw) on a sample of nine patients previously rehabilitated with fixed full-arch screw-retained prostheses following the Columbus Bridge Protocol (CBP) with four to six implants (total: 51) since at least 4 months. Two impressions were taken for each dental arch: one analogic plaster impression using pick-up copings and an open tray technique and a second one using an intra-oral scanner. Two milled metal substructures were realised. The precision and passivity of the substructures were clinically analysed through the Sheffield test and endo-oral radiographs. Laboratory scans of the plaster casts obtained from an intra-oral scanner (IOS) and of the plaster casts obtained from traditional impression were compared with the intraoral scans following Hausdorff’s method and an industrial digital method of optical detection to measure discrepancies. A Mann–Whitney test was performed in order to investigate average distances between surfaces after the superposition. Results: The Sheffield test demonstrated an excellent passivity of the frameworks obtained through both the digital and the analogic method. In 81.81% of cases (n = 9) both substructures were found to have a perfect fit with excellent passivity, while in 18.18% (n = 2) of cases the substructures were found to have a very slight discrepancy. From the radiographic examination, no gaps between the frameworks and the implant heads or multiunit abutments were observed, with 100% accuracy. By superimposing digital files of scans according to Hausdorff’s method, a statistically significant discrepancy (p = 0.006) was found between the digital scans and the digital models obtained from plaster impressions. Three-dimensional optical detection found a mean discrepancy of 0.11 mm between the analogic cast and the cast derived from the digital impression. Conclusions: The present study clinically demonstrates that milled implant-supported full-arch frameworks obtained through a digital scan and the herein described technique have an accuracy comparable to those obtained with traditional plaster impression.
1 September 2014 in International Journal of Periodontics & Restorative Dentistry
Paolo Pera, MD, DDS/Maria Menini, DDS, PhD/Marco Bevilacqua, DDS/Paolo Pesce, DDS/Francesco Pera, DDS, PhD/Alessio Signori, MSc/Tiziano Tealdo, DDS, MS, CDT: This prospective study reports the 6-year outcomes for patients rehabilitated with an immediate loading protocol of the maxilla (Columbus Bridge Protocol). In this study, 164 implants were inserted in 37 patients and loaded within 24 to 36 hours. Four implants failed during the first 6 months. At the 6-year follow-up, a mean bone loss of 1.52 mm was found. Significantly (P < .0083) less bone loss was found next to tapered implants compared with cylindric implants and next to machined collar implants compared with full acid-etched implants (P < .0083). No significant differences in bone loss were found in tilted versus upright implants or in mesial versus distal implant sites. In addition, there were no significant differences relating to either the degree of abutment angulation or the reason for tooth loss. (Int J Periodontics Restorative Dent 2014;34:657?665. doi: 10.11607/prd.1970)