Yu-Hsun Nien

Prof. Dr. Yu-Hsun Nien

Graduate School of Chemical and Materials Engineering, National Yunlin University of Science and Technology, 10 Douliu 64002, Taiwan
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 February 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Jung-Chuan ChouJung-Chuan Chou
Jung-Chuan Chou
SLSi-Hong Lin
Si-Hong Lin
TLTsu-Yang Lai
Tsu-Yang Lai
Po-Yu KuoPo-Yu Kuo
Po-Yu Kuo
CLChih-Hsien Lai
Chih-Hsien Lai
TSTzu-Yu Su
Tzu-Yu Su
In this study, the potentiometric arrayed glucose biosensors, which were based on zinc oxide (ZnO) or aluminum-doped zinc oxide (AZO) sensing membranes, were fabricated by using screen-printing technology and a sputtering system, and graphene oxide (GO) and Nafion-glucose oxidase (GOx) were used to modify sensing membranes by using the drop-coating method. Next, the material properties were characterized by using a Raman spectrometer, a field-emission scanning electron microscope (FE-SEM), and a scanning probe microscope (SPM). The sensing characteristics of the glucose biosensors were measured by using the voltage–time (V-T) measurement system. Finally, electrochemical impedance spectroscopy (EIS) was conducted to analyze their charge transfer abilities. The results indicated that the average sensitivity of the glucose biosensor based on Nafion-GOx/GO/AZO was apparently higher than that of the glucose biosensor based on Nafion-GOx/GO/ZnO. In addition, the glucose biosensor based on Nafion-GOx/GO/AZO exhibited an excellent average sensitivity of 15.44 mV/mM and linearity of 0.997 over a narrow range of glucose concentration range, a response time of 26 s, a limit of detection (LOD) of 1.89 mM, and good reproducibility. In terms of the reversibility and stability, the hysteresis voltages (VH) were 3.96 mV and 2.42 mV. Additionally, the glucose biosensor also showed good anti-inference ability and reproducibility. According to these results, it is demonstrated that AZO is a promising material, which could be used to develop a reliable, simple, and low-cost potentiometric glucose biosensor.

16 February 2010 in Polymer Composites
Verified
Journal Article
Closed access
PDF file
PYPei‐Hung Yeh
Pei‐Hung Yeh
Yu-Hsun NienYu-Hsun Nien
Yu-Hsun Nien
WCWei‐Chyum Chen
Wei‐Chyum Chen
WLWen‐Tsung Liu
Wen‐Tsung Liu

23 June 2021 in Polymers
Verified
Journal Article
Open access
PDF file
Yu-Hsun NienYu-Hsun Nien
Yu-Hsun Nien
ZKZhi-Xuan Kang
Zhi-Xuan Kang
TSTzu-Yu Su
Tzu-Yu Su
CHChih-Sung Ho
Chih-Sung Ho
Jung-Chuan ChouJung-Chuan Chou
Jung-Chuan Chou
YHYu-Hao Huang
Yu-Hao Huang
Potentiometric biosensors based on flexible arrayed silver paste electrode and copper-doped zinc oxide sensing film modified by iron-platinum nanoparticles (FePt NPs) are designed and manufactured to detect lactate in human. The sensing film is made of copper-doped zinc oxide (CZO) by a radio frequency (RF) sputtering system, and then modified by iron-platinum nanoparticles (FePt NPs). The surface morphology of copper-doped zinc oxide (CZO) is analyzed by scanning electron microscope (SEM). FePt NPs are analyzed by X-ray diffraction (XRD) and Fourier transform infrared spectroscopy (FTIR). The average sensitivity, response time, and interference effect of the lactate biosensors are analyzed by voltage-time (V-T) measurement system. The electrochemical impedance is analyzed by electrochemical impedance spectroscopy (EIS). The average sensitivity and linearity over the concentration range 0.2–5 mM are 25.32 mV/mM and 0.977 mV/mM, respectively. The response time of the lactate biosensor is 16 s, with excellent selectivity.

8 July 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Jung-Chuan ChouJung-Chuan Chou
Jung-Chuan Chou
CWCian-Yi Wu
Cian-Yi Wu
SLSi-Hong Lin
Si-Hong Lin
Po-Yu KuoPo-Yu Kuo
Po-Yu Kuo
CLChih-Hsien Lai
Chih-Hsien Lai
TLTsu-Yang Lai
Tsu-Yang Lai
Two types of urea biosensors were integrated with a wireless measurement system and microfluidic measurement system. The two biosensors used were (i) a magnetic beads (MBs)-urease/graphene oxide (GO)/titanium dioxide (TiO2)-based biosensor and (ii) an MBs-urease/GO/ nickel oxide (NiO)-based biosensor, respectively. The wireless measurement system work exhibited the feasibility for the remote detection of urea, but it will require refinement and modification to improve stability and precision. The microchannel fluidic system showed the measurement reliability. The sensing properties of urea biosensors at different flow rates were investigated. From the measurement results, the decay of average sensitivity may be attributed to the induced vortex-induced vibrations (VIV) at the high flow rate. In the aspect of wireless monitoring, the average sensitivity of the urea biosensor based on MBs-urease/GO/NiO was 4.780 mV/(mg/dl) and with the linearity of 0.938. In the aspect of measurement under dynamic conditions, the average sensitivity of the urea biosensor based on MBs-urease/GO/NiO were 5.582 mV/(mg/dl) and with the linearity of 0.959. Both measurements performed NiO was better than TiO2 according to the comparisons.

15 February 2019 in Journal of Polymer Research
Verified
Journal Article
Closed access
PDF file
PCPao-Lin Chuang
Pao-Lin Chuang
Yu-Hsun NienYu-Hsun Nien
Yu-Hsun Nien

4 May 2020 in Energies
Verified
Journal Article
Open access
PDF file
Yu-Hsun NienYu-Hsun Nien
Yu-Hsun Nien
HCHuang-Hua Chen
Huang-Hua Chen
HHHui-Hsuan Hsu
Hui-Hsuan Hsu
MRManjunath Rangasamy
Manjunath Rangasamy
GHGeng-Ming Hu
Geng-Ming Hu
JCJun-Xiang Chang
Jun-Xiang Chang
Dye-sensitized solar cells (DSSCs) are low-cost solar cells belonging to the thin-film photovoltaic cell type. In this study, we studied the photovoltaic performances of DSSCs based on titanium dioxide (TiO2) nanofibers (NFs) containing silver (Ag) nanoparticles (NPs) under low illumination. We used the sol-gel method with the electrospinning technique to prepare the TiO2 NFs containing Ag NPs. Herein, we used two ways to add TiO2/Ag NFs to modify the photoelectrode successfully and enhance the performance of DSSCs. One way was that the TiO2/Ag NFs were mixed with pristine TiO2; the other way was that the TiO2/Ag NFs were seeded beside the TiO2 colloid layer as an additional layer on the photoelectrode of the DSSC. According to this experiment, the photovoltaic conversion efficiency of the DSSC which had TiO2/Ag NF seeded as an additional layer on the photoelectrode (5.13%) was increased by 28% compared to the DSSC without the photoelectrode modification (3.99%). This was due to the suppression of electron recombination and the more effective utilization of the light radiation by adding the TiO2/Ag NFs. Because of the good conductivity of Ag, the electrons were quickly transported and electron recombination was reduced. In addition, the photovoltaic conversion efficiency of the DSSC which had TiO2/Ag NF seeded as an additional layer on the photoelectrode increased from 5.13% to 6.23% during the decrease in illumination from 100 mW/cm2 to 30 mW/cm2; however, its photovoltaic conversion efficiency decreased to 5.31% when the illumination was lowered to 10 mW/cm2.