Jung-Chuan Chou

Dr. Jung-Chuan Chou

National Yunlin University of Science and Technology · Department of Electronic Engineering and Graduate School of Electronic and Optoelectronic Engineering
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 April 2009 in Sensors
Verified
Journal Article
Open access
PDF file
YLYi-Hung Liao
Yi-Hung Liao
Jung-Chuan ChouJung-Chuan Chou
Jung-Chuan Chou
ThepH sensing and nonideal characteristics of a ruthenium nitride (RuN) sensing membrane pH sensor were investigated. RuN thin films were deposited from a 99.9% ruthenium target on p-type silicon substrates using radio frequency (r.f.) sputtering with N2 gas. Subsequently, the nanometric structure and surface morphology of RuN thin films were determined. The sensitivity of the RuN sensing membrane pH sensor was 58.03 mV/pH, obtained from ID-VG curves with a current-voltage (I-V) measurement system in standard buffer solutions from pH 1 to pH 13 at room temperature (25 °C). Moreover, the nonideal characteristics of the RuN sensing membrane, such as temperature coefficient, drift with light influence, drift rate and hysteresis width, etc. were also investigated. Finally, the sensing characteristics of the RuN membrane were compared with titanium nitride (TiN), aluminum nitride (AlN) and silicon nitride (Si3N4) membranes.

1 September 2019 in Vacuum
Verified
Journal Article
Closed access
YNYu-Hsun Nien
Yu-Hsun Nien
HCHuang-Hua Chen
Huang-Hua Chen
HHHui-Hsuan Hsu
Hui-Hsuan Hsu
PKPo-Yu Kuo
Po-Yu Kuo
Jung-Chuan ChouJung-Chuan Chou
Jung-Chuan Chou
CKCheng-Chu Ko
Cheng-Chu Ko

11 February 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Jung-Chuan ChouJung-Chuan Chou
Jung-Chuan Chou
SLSi-Hong Lin
Si-Hong Lin
TLTsu-Yang Lai
Tsu-Yang Lai
Po-Yu KuoPo-Yu Kuo
Po-Yu Kuo
CLChih-Hsien Lai
Chih-Hsien Lai
TSTzu-Yu Su
Tzu-Yu Su
In this study, the potentiometric arrayed glucose biosensors, which were based on zinc oxide (ZnO) or aluminum-doped zinc oxide (AZO) sensing membranes, were fabricated by using screen-printing technology and a sputtering system, and graphene oxide (GO) and Nafion-glucose oxidase (GOx) were used to modify sensing membranes by using the drop-coating method. Next, the material properties were characterized by using a Raman spectrometer, a field-emission scanning electron microscope (FE-SEM), and a scanning probe microscope (SPM). The sensing characteristics of the glucose biosensors were measured by using the voltage–time (V-T) measurement system. Finally, electrochemical impedance spectroscopy (EIS) was conducted to analyze their charge transfer abilities. The results indicated that the average sensitivity of the glucose biosensor based on Nafion-GOx/GO/AZO was apparently higher than that of the glucose biosensor based on Nafion-GOx/GO/ZnO. In addition, the glucose biosensor based on Nafion-GOx/GO/AZO exhibited an excellent average sensitivity of 15.44 mV/mM and linearity of 0.997 over a narrow range of glucose concentration range, a response time of 26 s, a limit of detection (LOD) of 1.89 mM, and good reproducibility. In terms of the reversibility and stability, the hysteresis voltages (VH) were 3.96 mV and 2.42 mV. Additionally, the glucose biosensor also showed good anti-inference ability and reproducibility. According to these results, it is demonstrated that AZO is a promising material, which could be used to develop a reliable, simple, and low-cost potentiometric glucose biosensor.

31 January 2019 in IEEE Transactions on Nanotechnology
Verified
Journal Article
Closed access
Jung-Chuan ChouJung-Chuan Chou
Jung-Chuan Chou
CWCian-Yi Wu
Cian-Yi Wu
Po-Yu KuoPo-Yu Kuo
Po-Yu Kuo
CLChih-Hsien Lai
Chih-Hsien Lai
YNYu-Hsun Nien
Yu-Hsun Nien
YLYi-Hung Liao
Yi-Hung Liao
A flexible urea sensor based on urease-magnetic beads (MBs) and graphene oxide (GO) has been synthesized on nickel oxide (NiO) as matrix. The flexible urea sensor was constructed by sputtering technology and screen-printing technology. A sequential titrating of GO and magnetic beads over the surface on NiO film was adopted for the sensor preparation by the covalent binding with urease. The electrochemical impedance, response time and drift effect of the urea sensor based on MBs, GO and NiO were recorded using electrochemical impedance spectroscopy (EIS) and voltage-time (V-T) measurement system.

8 July 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Jung-Chuan ChouJung-Chuan Chou
Jung-Chuan Chou
CWCian-Yi Wu
Cian-Yi Wu
SLSi-Hong Lin
Si-Hong Lin
Po-Yu KuoPo-Yu Kuo
Po-Yu Kuo
CLChih-Hsien Lai
Chih-Hsien Lai
TLTsu-Yang Lai
Tsu-Yang Lai
Two types of urea biosensors were integrated with a wireless measurement system and microfluidic measurement system. The two biosensors used were (i) a magnetic beads (MBs)-urease/graphene oxide (GO)/titanium dioxide (TiO2)-based biosensor and (ii) an MBs-urease/GO/ nickel oxide (NiO)-based biosensor, respectively. The wireless measurement system work exhibited the feasibility for the remote detection of urea, but it will require refinement and modification to improve stability and precision. The microchannel fluidic system showed the measurement reliability. The sensing properties of urea biosensors at different flow rates were investigated. From the measurement results, the decay of average sensitivity may be attributed to the induced vortex-induced vibrations (VIV) at the high flow rate. In the aspect of wireless monitoring, the average sensitivity of the urea biosensor based on MBs-urease/GO/NiO was 4.780 mV/(mg/dl) and with the linearity of 0.938. In the aspect of measurement under dynamic conditions, the average sensitivity of the urea biosensor based on MBs-urease/GO/NiO were 5.582 mV/(mg/dl) and with the linearity of 0.959. Both measurements performed NiO was better than TiO2 according to the comparisons.

23 June 2021 in Polymers
Verified
Journal Article
Open access
PDF file
Yu-Hsun NienYu-Hsun Nien
Yu-Hsun Nien
ZKZhi-Xuan Kang
Zhi-Xuan Kang
TSTzu-Yu Su
Tzu-Yu Su
CHChih-Sung Ho
Chih-Sung Ho
Jung-Chuan ChouJung-Chuan Chou
Jung-Chuan Chou
YHYu-Hao Huang
Yu-Hao Huang
Potentiometric biosensors based on flexible arrayed silver paste electrode and copper-doped zinc oxide sensing film modified by iron-platinum nanoparticles (FePt NPs) are designed and manufactured to detect lactate in human. The sensing film is made of copper-doped zinc oxide (CZO) by a radio frequency (RF) sputtering system, and then modified by iron-platinum nanoparticles (FePt NPs). The surface morphology of copper-doped zinc oxide (CZO) is analyzed by scanning electron microscope (SEM). FePt NPs are analyzed by X-ray diffraction (XRD) and Fourier transform infrared spectroscopy (FTIR). The average sensitivity, response time, and interference effect of the lactate biosensors are analyzed by voltage-time (V-T) measurement system. The electrochemical impedance is analyzed by electrochemical impedance spectroscopy (EIS). The average sensitivity and linearity over the concentration range 0.2–5 mM are 25.32 mV/mM and 0.977 mV/mM, respectively. The response time of the lactate biosensor is 16 s, with excellent selectivity.