Daniel Dudek

Dr. Daniel Dudek

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2021 in Materials
Verified
Journal Article
Open access
PDF file
Marcin MałekMarcin Małek
Marcin Małek
WŁWaldemar Łasica
Waldemar Łasica
Marta Daniela KadelaMarta Daniela Kadela
Marta Daniela Kadela
Janusz KluczynskiJanusz Kluczynski
Janusz Kluczynski
DDDaniel Dudek
Daniel Dudek
In accordance with the principles of sustainable development, environmentally friendly, low-emission, and energy-intensive materials and technologies, as well as waste management, should be used. Concrete production is responsible for significant energy consumption and CO2 production; therefore, it is necessary to look for new solutions in which components are replaced by other materials, preferably recycled. A positive way is to use glass waste. In order to determine the effect of a significant glass cullet content on the properties of concrete, glass powder was used as a filler and 100% glass aggregate. The cement–glass composite has low tensile strength and brittle failure. In order to improve tensile strength, the effects of adding polypropylene fibres on the mechanical properties of the composite were investigated. With the addition of 300, 600, 900, 1200, and 1500 g/m3 of fibres, which corresponds to 0.0625%, 0.1250%, 0.1875%, 0.2500%, and 0.3125% of cement mass, respectively, flexural strength increased compared with the base sample by 4.1%, 8.2%, 14.3%, 20.4%, and 26.5%, respectively, while the increase in splitting strength was 35%, 45%, 115%, 135%, and 185%, respectively. Moreover, with the addition of fibres, a decrease in slump by 25.9%, 39.7%, 48.3%, 56.9%, and 65.5%, respectively, compared with the reference specimen was determined.

6 March 2023 in Materials
Verified
Journal Article
Open access
PDF file
Marta Daniela KadelaMarta Daniela Kadela
Marta Daniela Kadela
Marcin MałekMarcin Małek
Marcin Małek
MJMateusz Jackowski
Mateusz Jackowski
MKMateusz Kunikowski
Mateusz Kunikowski
AKAgnieszka Klimek
Agnieszka Klimek
MRMarek Rośkowicz
Marek Rośkowicz
The increasing amount of waste from the vulcanization industry has become a serious environmental challenge. Even the partial reuse of the steel contained in tires as dispersed reinforcement in the production of new building materials may contribute to reducing the environmental impact of this industry while supporting the principle of sustainable development. In this study, the concrete samples were made of Portland cement, tap water, lightweight perlite aggregates, and steel cord fibers. Two different addition of steel cord fibers (1.3% and 2.6% wt. of concrete, respectively) were used. The samples of lightweight concrete based on perlite aggregate with steel cord fiber addition showed a significant increase in compressive (18–48%), tensile (25–52%), and flexural strength (26–41%). Moreover, higher thermal conductivity and thermal diffusivity were reported after incorporating steel cord fibers into the concrete matrix; however, the specific heat values decreased after these modifications. The highest values of thermal conductivity and thermal diffusivity were obtained for samples modified with a 2.6% addition of steel cord fibers and were equal to 0.912 ± 0.002 W/mK and 0.562 ± 0.002 µm2/s, respectively. Maximum specific heat, on the other hand, was reported for plain concrete (R)—1.678 ± 0.001 MJ/m3 K.

15 December 2021 in Materials
Verified
Journal Article
Open access
PDF file
DDDaniel Dudek
Daniel Dudek
Marta Daniela KadelaMarta Daniela Kadela
Marta Daniela Kadela
Marcin MałekMarcin Małek
Marcin Małek
The article presents the pull-out strength tests carried out on M10 expansion anchors in non-cracked and cracked concrete with a crack width cw = 0.30 mm. The breaking loads and the average pull-out strength of anchors in fibre-reinforced concrete substrates were determined. Fibre content ratios of 15, 30 and 50 kg/m3 were used. In addition, two different classes of concrete (C20/25 and C50/60) were tested. The addition of steel fibres caused a decrease in the pull-out strength by 5% for non-cracked concrete of C20/25 class and fibre content up to 30 kg/m3 and a further 7% for the remaining specified dosage. While for concrete of the C50/60 class, it a decrease in the pull-out strength of up to 20% was observed. For cracked concrete class C20/25 with crack initiation cw = 0.30 mm, the reduction was from 9% to 16% in relation to non-cracked concrete and a maximum of 18% for the fibre content of 50 kg/m3. The difference between the tensile load capacity of C50/60 class cracked and non-cracked concrete was lower than 5% and fell within the measurement error.

28 February 2024 in Materials
Verified
Journal Article
Open access
PDF file
KKKazimierz Konieczny
Kazimierz Konieczny
DDDaniel Dudek
Daniel Dudek
Alfred KukiełkaAlfred Kukiełka
Alfred Kukiełka
Pull-out strength tests conducted on screw anchors in uncracked concrete substrates of the C25/30 class are presented in this article. The destructive force for anchor–concrete fasting was tested, and in the next step, the average pull-out strengths of screw anchors in concrete substrates with and without the addition of steel fiber were determined. Currently, the pull-out strengths of anchors in fiber-reinforced concrete substrates are defined as for unreinforced concrete substrates. Therefore, pull-out tests were performed for screw anchors in fiber-reinforced concrete substrates. Fiber contents of 10, 20, 30, and 50 kg/m3 were used. An increase in the load capacity of screw anchors in a fiber-reinforced concrete substrate was demonstrated in a pull-out test compared to base samples without fibers. The coefficient related to the actual fastening behavior of a screw anchor in the fiber-reinforced concrete substrate was determined. It was assumed that a coefficient of 13.10 should be adopted. This was the lowest value obtained for the load capacity in this study for screw anchors in a fiber-reinforced concrete substrate.

24 May 2024 in MATEC Web of Conferences
Verified
Journal Article
Open access
PDF file
KKKazimierz Konieczny
Kazimierz Konieczny
DDDaniel Dudek
Daniel Dudek
AKAlfred Kukiełka
Alfred Kukiełka
Along with the development of engineering construction techniques, the interest in the issue of fastenings increases. In the construction of new facilities as well as in renovation works, a wide range of fasteners is currently used, enabling quick connections and safe fastening of various types of structural and installation elements. This progress is particularly visible in fixings made in concrete substrates. During assembly and during operation, the fasteners are subject to the influence of many external factors that may significantly affect their load capacity. Such factors include the type and nature of the load to be transferred, the strength and condition of the substrate, the temperature at which the fasteners will be installed and used. The technical parameters of fasteners determined by means of theoretical calculations still do not provide adequate accuracy, so that this method can be used to determine their impact on the behaviour of fasteners during their long-term operation. Therefore, their experimental verification is still required. In the countries of the European Union, the development of the rules for the use and assessment of expansion and bonded fasteners has been entrusted to the European Organization for Technical Assessment - EOTA. This organization groups bodies authorized by EU Member States to provide European technical assessments on the terms set out in Regulation No. 305/2011 (CPR) 2013. The current list of EOTA guidelines for expansion and bonded anchors used in the construction industry, specifying the basis for their use as well as standards for the design of fasteners. The scope and methods of fastener testing are presented in the EOTA guidelines. The purpose of these tests is to determine whether the behavior of the fasteners during their use will be safe and effective, taking into account the unfavourable conditions that can be encountered both during its installation and use. The publication will present the basic structural properties of fasteners made in drilled holes in concrete substrates reinforced with steel and polypropylene fibres.

1 October 2017 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
PKPrzemyslaw Knap
Przemyslaw Knap
DDDaniel Dudek
Daniel Dudek
Areas affected by seismic and mining disturbances are tied to a risk of damage to engineering structures. The problem may result in permanent damaging of fasteners installed in buildings. Such damage may affect the strength of different types of construction fasteners and connectors. The technical condition of fastening elements should be assessed, and conclusions formed regarding the causes of damage and ways to secure those elements. In order to determine the pull-out resistance of fasteners set in a concrete base, the effects of disturbances were simulated as cracks in the concrete. Additionally, the influence of tolerances for openings made using drills with diameters dmin, dnom and dmax presented in the study was also determined. Introduction of the variables described may influence the pull-out resistance of the steel and plastic/metal anchors. The article presents the results of tests for specific pull-out resistances of steel and plastic/metal anchors installed in a concrete base in normal-weight non-cracked concrete and normal-weight cracked concrete where crack initiation was at 0.20 mm and 0.35 mm. All tests were carried out for the purposes of this paper at normal temperature and with C20/25 concrete, without factoring in influence of concrete or air moisture content.