Rik Verplancke

Dr. Rik Verplancke

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2017 in Displays
Verified
Journal Article
Closed access
CVCeline Vanhaverbeke
Celine Vanhaverbeke
RVRik Verplancke
Rik Verplancke
JSJelle De Smet
Jelle De Smet
DCDieter Cuypers
Dieter Cuypers
HSHerbert De Smet
Herbert De Smet

16 December 2019 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
PDF file
RVRik Verplancke
Rik Verplancke
MCMaarten Cauwe
Maarten Cauwe
David SchaubroeckDavid Schaubroeck
David Schaubroeck
DCDieter Cuypers
Dieter Cuypers
BVBjorn Vandecasteele
Bjorn Vandecasteele
MBMaaike Op de Beeck
Maaike Op de Beeck
In this work, the development of an active high-density transverse intrafascicular micro-electrode (hd-TIME) probe to interface with the peripheral nervous system is presented. The TIME approach is combined with an active probe chip, resulting in improved selectivity and excellent signal-to-noise ratio. The integrated multiplexing capabilities reduce the number of external electrical connections and facilitate the positioning of the probe during implantation, as the most interesting electrodes of the electrode array can be selected after implantation. The probe chip is packaged using thin-film manufacturing techniques to allow for a minimally invasive electronic package. Special attention is paid to the miniaturization, the mechanical flexibility and the hermetic encapsulation of the device. A customized probe chip was designed and packaged using a flexible, implantable thin electronic package (FITEP) process platform. The platform is specifically developed for making slim, ultra-compliant, implantable complementary metal-oxide-semiconductor based electronic devices. Multilayer stacks of polyimide films and HfO 2 /Al 2 O 3 /HfO 2 layers deposited via atomic layer deposition act as bidirectional diffusion barriers and are key to the hermetic encapsulation. Their efficacy was demonstrated both by water vapor transmission rate tests and accelerated immersion tests in phosphate buffered saline at 60 °C. Using the hd-TIME probe, an innovative implantation method is developed to prevent the fascicles from moving away when the epineurium is pierced. In addition, by transversally implanting the hd-TIME probe in the proximal sciatic nerve of a rat, selective activation within the nerve was demonstrated. The FITEP process platform can be applied to a broader range of integrated circuits and can be considered as an enabler for other biomedical applications.

15 March 2022 in IEEE Journal of Selected Topics in Quantum Electronics
Verified
Journal Article
Open access
IBIvan-Lazar Bundalo
Ivan-Lazar Bundalo
PMPadraic E. Morrissey
Padraic E. Morrissey
AAAndrea Annoni
Andrea Annoni
Roel BaetsRoel Baets
Roel Baets
FBFabrice Blache
Fabrice Blache
POPeter O'Brien
Peter O'Brien
This paper demonstrates how the PIXAPP Photonics Packaging Pilot Line uses its extensive packaging capabilities across its European partner network to design and assemble a highly integrated silicon photonic-based optical transceiver. The processes used are based on PIXAPP's open access packaging design rules or Assembly Design Kit (ADK). The transceiver was designed to have the Tx and Rx elements integrated on to a single silicon photonic chip, together with flipchip control electronics, hybrid laser and micro-optics. The transceiver used the on-chip micro-optics to enable a pluggable fiber connection, avoiding the need to bond optical fibers directly to the photonic chip. Finally, the packaged transceiver module was tested, showing 56 Gb/s loop-back modulation and de-modulation, validating both the transmitter and receiver performance.

25 March 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
AKAdriana Karcz
Adriana Karcz
ASAnn Van Soom
Ann Van Soom
KSKatrien Smits
Katrien Smits
Sandra Van VlierbergheSandra Van Vlierberghe
Sandra Van Vlierberghe
RVRik Verplancke
Rik Verplancke
JVJan Vanfleteren
Jan Vanfleteren
Digital microfluidics (DMF) holds great potential for the alleviation of laboratory procedures in assisted reproductive technologies (ARTs). The electrowetting on dielectric (EWOD) technology provides dynamic culture conditions in vitro that may better mimic the natural embryo microenvironment. Thus far, EWOD microdevices have been proposed for in vitro gamete and embryo handling in mice and for analyzing the human embryo secretome. This article presents the development of the first microfluidic chip utilizing EWOD technology designed for the manipulation of bovine embryos in vitro. The prototype sustains the cell cycles of embryos manipulated individually on the chips during in vitro culture (IVC). Challenges related to the chip fabrication as well as to its application during bovine embryo IVC in accordance with the adapted on-chip protocol are thoroughly discussed, and future directions for DMF in ARTs are indicated.

31 December 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
BVBram Vandekerckhove
Bram Vandekerckhove
JMJeroen Missinne
Jeroen Missinne
KVKristl Vonck
Kristl Vonck
PBPieter Bauwens
Pieter Bauwens
RVRik Verplancke
Rik Verplancke
JVJan Vanfleteren
Jan Vanfleteren
Epilepsy is a chronic, neurological disorder affecting millions of people every year. The current available pharmacological and surgical treatments are lacking in overall efficacy and cause side-effects like cognitive impairment, depression, tremor, abnormal liver and kidney function. In recent years, the application of optogenetic implants have shown promise to target aberrant neuronal circuits in epilepsy with the advantage of both high spatial and temporal resolution and high cell-specificity, a feature that could tackle both the efficacy and side-effect problems in epilepsy treatment. Optrodes consist of electrodes to record local field potentials and an optical component to modulate neurons via activation of opsin expressed by these neurons. The goal of optogenetics in epilepsy is to interrupt seizure activity in its earliest state, providing a so-called closed-loop therapeutic intervention. The chronic implantation in vivo poses specific demands for the engineering of therapeutic optrodes. Enzymatic degradation and glial encapsulation of implants may compromise long-term recording and sufficient illumination of the opsin-expressing neural tissue. Engineering efforts for optimal optrode design have to be directed towards limitation of the foreign body reaction by reducing the implant’s elastic modulus and overall size, while still providing stable long-term recording and large-area illumination, and guaranteeing successful intracerebral implantation. This paper presents an overview of the challenges and recent advances in the field of electrode design, neural-tissue illumination, and neural-probe implantation, with the goal of identifying a suitable candidate to be incorporated in a therapeutic approach for long-term treatment of epilepsy patients.

2 May 2022 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
AKAdriana Karcz
Adriana Karcz
ASAnn Van Soom
Ann Van Soom
KSKatrien Smits
Katrien Smits
RVRik Verplancke
Rik Verplancke
Sandra Van VlierbergheSandra Van Vlierberghe
Sandra Van Vlierberghe
JVJan Vanfleteren
Jan Vanfleteren
Electric fields in in vitro processing of gametes and embryos: dielectrophoresis (DEP) and electrowetting on dielectric (EWOD).