We report the demonstration of a normal-incidence p-i-n germanium-tin ( ) photodetector on silicon-on-insulator substrate for 2 μm wavelength application. The DC and RF characteristics of the devices have been characterized. A dark current density under bias of approximately is achieved at room temperature, and the optical responsivity of 14 mA/W is realized for illumination wavelength of 2 μm under reverse bias. In addition, a 3 dB bandwidth ( ) of around 30 GHz is achieved at , which is the highest reported value among all group III–V and group IV photodetectors working in the 2 μm wavelength range. This work illustrates that a GeSn photodetector has great prospects in 2 μm wavelength optical communication.
1 March 2021 in IEEE Transactions on Biomedical Engineering
Objective: As a newly developed technique, focused microwave breast hyperthermia (FMBH) can provide accurate and cost-effective treatment of breast tumors with low side effect. A clinically feasible FMBH system requires a guidance technique to monitor the microwave power distribution in the breast. Compressive thermoacoustic tomography (CTT) is a suitable guidance approach for FMBH, which is more cost-effective than MRI. However, no experimental validation based on a realized FMBH-CTT system has been reported, which greatly hinders the further advancement of this novel approach. Methods: We developed a preclinical system prototype for the FMBH-CTT technique, containing a microwave phased antenna array, a microwave source, an ultrasound transducer array and associated data acquisition module. Results: Experimental results employing homogeneous and inhomogeneous breast-mimicking phantoms demonstrate that the CTT technique can offer reliable guidance for the entire process of the FMBH. In addition, small phase noises do not deteriorate the overall performance of the system prototype. Conclusion: The realized preclinical FMBH-CTT system prototype is capable for noninvasive, accurate and low-side-effect breast tumor treatment with effective guidance. Significance: The experimentally validated FMBH-CTT system prototype provides a feasible paradigm for CTT guided FMBH, establishes a practical platform for future improvement of this technique, and paves the way for potential clinical translation.
Hollow-core fiber (HCF) has been attracting broad interests in recent decades, and has extended the communication window to longer wavelength, 2 micron. In this paper, we present a demonstration of low-latency HCF short-reach optical interconnection at 2 micron, achieving a high single-lane speed of 100 Gbps. High physical speed (near vacuum-light-speed) and high information speed (100-Gbps) optical interconnection with 100-m transmission distance is experimentally achieved with error-free performance. Probabilistically shaped discrete multi-tone (PS-DMT) modulation with entropy loading is employed to accommodate the deteriorated frequency response caused by the mode dispersion in HCF. Compared with conventional solid-core fiber (SCF), HCF contributes 30.95% (1.5-'s per kilometer) latency reduction for the physical link. The system level latency reduction is 28% for 1-km interconnection distance (11% for 100-m), with respect to a microsecond-scale switching network for typical datacenter applications. This work substantially leaps over the 100G milestone of 2-micron HCF optical interconnection, and shows the potentiality with lower latency and further higher capacity.
Ultra-compact spectrometers are becoming increasingly popular for their promising applications in biomedical analysis, environmental monitoring, and food safety. In this work, we report a single-pixel-photodetector spectrometer with a spectral range from 480 nm to 820 nm, based on the AlGaAs/GaAs p-graded-n junction with a voltage-tunable optical response. To reconstruct the optical spectrum, we propose a tailored method called Neural Spectral Fields (NSF) that leverages the unique wavelength and bias-dependent responsivity matrix. Our spectrometer achieves a high spectral wavelength accuracy of up to 0.30 nm and a spectral resolution of up to 10 nm. Additionally, we demonstrate the high spectral imaging performance of the device. The compatibility of our demonstration with the standard III-V process greatly accelerates the commercialization of miniaturized spectrometers.